I NS T ALL ATI O N  

 

Das  Gerät  ist  für  feste  Installation  in  Innenräumen  (trockene 
Räume)  zum  Einbau  in  Verteilerschränken  durch  autorisiertes 
Fachpersonal  unter  Einhaltung  der  technischen  Daten  und  gängi-
gen Sicherheitsvorschriften bestimmt. 
 

 

Das Gerät muss mit einem Leitungsschutzschalter abgesichert wer-
den. 
 

 

Alle  Ausgänge  müssen  an  der  gleichen  Sicherungsgruppe  ange-
schlossen werden. 
 

I NS T ALL ATI O N    

 

This  device  is  suitable  for  DIN  rail  mounting  indoors  (dry  rooms) 
through  authorised  personnel  in  compliance  with  the  technical  data 
and common safety regulations. 
 
 

 

This device needs to be protected by a circuit breaker. 
 
 

 

All outputs must be connected to the same fuse group. 

 

KONFI GU R ATI ON  M I T  E -TO OL  

Die Konfiguration des Omnio Aktors erfolgt entweder manuell am Gerät selber oder 
durch ARCO Technologie über Funk mit der Planungssoftware 

E-Tool Goldlizenz

Zum Erwerb der Goldlizenz kontaktieren Sie bitte AWAG Elektrotechnik AG unter 

www.awag.ch

. Die Software sowie eine detaillierte System- und Funktionsbeschrei-

bung von ARCO sind auf der Omnio Webseite 

www.omnio.ch

 zu finden. 

 
Standardmässig  ist  der  ARCO-Fernzugriff  beim  Aufstarten  des  Gerätes  während 
einer halben Stunde freigegeben. Er lässt sich aber auch über einen Sicherheits-
code einschalten. Die Standardeinstellung des Sicherheitscodes ist 

A9081919

M ANUE LLE   KONFI GU R ATI ON  

Die manuelle Konfiguration erfolgt mit Hilfe der oben erwähnten Bedienelemente. 
Zur Vereinfachung wird die Position des Drehschalters HEX auf der 7-Segment An-
zeige SEG angezeigt. Bei zweistelligen Positionsnummern (10...15) erscheint zu-
erst die Zehnerziffer und danach die Einerziffer, z.B. 1 

– 2 für Position 12. 

S E N D E R   E I N L E R N E N  

Beim Einlernvorgang wird dem Sender eine Funktion auf dem Aktor zugewiesen. 
Dabei darf der Sender nicht mehr als 5 m vom Aktor entfernt sein. Eine Übersicht 
aller  Funktionen  ist  in  Tabelle  1  FUNKTIONEN  zu  finden.  Verschiedene  Sender 
können  auf  dem  gleichen  Aktor  ganz  unterschiedliche  Funktionen  ausüben,  z.B. 
Sender 1 = 

S01: Schalten mit Wippe 

und

 

Sender 2 = 

S05: Schrittschalter.

 

 

1. Funktion wählen, Drehschalter HEX gemäss Tabelle 1 (Spalte 1) einstellen. 
2. Einlernmodus durch einen langen Tastendruck (2 s) auf LRN aktivieren. LRN 

leuchtet und CLR blinkt. 

3. Kanal durch weiteren Tastendruck auf LRN wählen. Die 7-Segment Anzeige 

SEG zeigt die Kanalnummer an

: A = alle Kanäle, 1…4 = Kanal 1…4. 

4. Drehschalter HEX gemäss Tabelle 1 (Spalte 3) einstellen. 
5. Sender zweimal drücken. CLR leuchtet 1 s und blinkt danach weiter. 
6. CLR drücken, LRN und CLR erlöschen. 

S E N D E R   L Ö S C H E N  

Eine Übersicht ist in Tabelle 2 SENDER LÖSCHEN zu finden. 
 

1. Drehschalter HEX auf Position 0 stellen. 
2. Löschmodus durch einen langen Tastendruck (2 s) auf CLR aktivieren. LRN 

blinkt und CLR leuchtet, die 7-Segment Anzeige 

SEG zeigt „C“ an. 

3. Sender zweimal drücken. LRN leuchtet 1 s und blinkt danach weiter. 
4. CLR drücken, LRN und CLR erlöschen. 

F U N K T I O N S P AR A M E T E R  

Funktionsparameter (z.B. Verzögerungszeiten) sind nur für den jeweiligen Sender 
gültig.  Eine  Übersicht  aller  Funktionsparameter  ist  in  Tabelle  3  FUNKTIONS-PA-
RAMETER zu finden. 
 

1. Drehschalter HEX gemäss Tabelle 3 (Spalte 1) einstellen. 
2. Einlernmodus durch einen langen Tastendruck (2 s) auf LRN aktivieren. LRN 

leuchtet und CLR blinkt, die 7-Segment Anzeige 

SEG zeigt „t“ an.  

3. Drehschalter HEX gemäss Tabelle 3 (Spalte 3) einstellen. 
4. Sender zweimal drücken. CLR leuchtet 1 s und blinkt danach weiter. 
5. Je nach Parameter Schritt 3) und 4) wiederholen. 
6. CLR drücken, LRN und CLR erlöschen. 

G E R Ä T E P A R AM E T E R  

Geräteparameter  (z.B.  Aufstartverhalten)  sind  für  den  ganzen  Aktor  gültig.  Eine 
Übersicht aller Geräteparameter ist in Tabelle 4 GERÄTEPARAMETER zu finden. 
 

1. Drehschalter HEX gemäss Tabelle 5 (Spalte 1) einstellen. 
2. Einlernmodus durch einen langen Tastendruck (2 s) auf LRN aktivieren. LRN 

leuchtet und CLR blinkt, die 7-Segment Anzeige 

SEG zeigt „L“ an. 

3. Drehschalter HEX gemäss Tabelle 5 (Spalte 3) einstellen. 
4. LRN drücken, LRN und CLR erlöschen. 

 

CONFI GU R ATI ON  W I TH  E -TOOL 

Omnio actuators can be configured either manually on the device itself or by radio 
with the  software 

E-Tool  Gold license

  through ARCO technology.  Please contact 

AWAG Elektrotechnik AG at 

www.awag.ch

 to obtain the license. The software and 

a detailed description of the ARCO system and all its functions can be found on the 
Omnio website 

www.omnio.ch

 
By default, ARCO remote commissioning is unlocked for 30 minutes at power-on of 
the  device.  It  can  also  be  unlocked  via  a  security  code.  The  default  value  is 

A9081919

 

M ANU AL  CONFI GU R ATI ON    

The manual configuration is  done  with the  above mentioned operating elements. 
As a help the position of the rotary switch HEX is indicated on the 7-segment dis-
play. For two-digit numbers (10...15) first the tens digit and then the unit digit ap-
pears, e.g. 1 

– 2 for position 12. 

P R O G R AM   T R A N S M I T T E R    

At programming the transmitter is assigned a function on the actuator. During the 
process  the transmitter must  not be further than 5 m away from the  actuator. An 
overview of all functions can be found in table 1 FUNCTIONS. Different transmitters 
can have very different functions on the same actuator as well, e.g. transmitter 1 = 

S01: Switch with rocker 

and

 

transmitter 2 = 

S05: Step switch

 

1. Choose function, turn rotary switch HEX according to table 1 (column 1). 
2. Enable programming mode by pressing the LRN button 2 s. LRN illuminates 

and CLR blinks. 

3. Choose channel by subsequently pressing LRN. The 7-segment display SEG 

indicates the channel number

: A = all channels, 1…4 = channel 1…4. 

4. Turn rotary switch HEX according to table 1 (column 3). 
5. Press transmitter twice. CLR illuminates and then blinks. 
6. Press CLR, both LRN and CLR go out. 

D E L E T E   T R A N S M I T T E R  

An overview can be found in table 2 DELETE TRANSMITTER. 
 

1. Turn rotary switch HEX to position 0. 
2. Enable deletion mode by pressing the CLR button 2 s. LRN blinks and CLR 

illuminates, the 7-

segment display SEG displays “C”. 

3. Press transmitter twice. LRN illuminates 1 s and then blinks. 
4. Press CLR, both LRN and CLR go out. 

F U N C T I O N   P A R AM E T E R S  

Function parameters (e.g. delay times) are only valid for the corresponding trans-
mitter. An overview of all function parameters can be found in table 3 FUNCTION 
PARAMETERS. 
 

1. Turn rotary switch HEX according to table 3 (column 1). 
2. Enable programming mode by pressing the LRN button 2 s. LRN illuminates 

and CLR blinks, the 7-

segment display SEG displays “t”. 

3. Turn rotary switch HEX according to table 3 (column 3). 
4. Press transmitter twice. CLR illuminates 1 s and then blinks. 
5. Repeat steps 3) and 4) depending on the parameter. 
6. Press CLR, both LRN and CLR go out. 

D E V I C E   P A R AM E T E R S  

Device  parameters  (e.g.  start-up  behaviour)  are  valid  for  the  entire  actuator.  An 
overview of all device parameters can be found in table 4 DEVICE PARAMETERS. 
 

1. Turn rotary switch HEX according to table 5 (column 1). 
2. Enable programming mode by pressing the LRN button 2 s. LRN illuminates 

and CLR blinks, the 7-

segment display SEG displays “L”. 

3. Turn rotary switch HEX according to table 5 (column 3). 
4. Press LRN, both LRN and CLR go out. 

 

 

 

Summary of Contents for REGS12/08M

Page 1: ...UKTBESCHREIBUNG Der Omnio REG Multi Schaltaktor 8 Kanal REGS12 08 ist ein Ger t zum Schalten von elektrischen Verbrauchern Seine acht potentialfreien Ausg nge k nnen von bis zu 50 Omnio Funksendern an...

Page 2: ...stellen 4 Sender zweimal dr cken CLR leuchtet 1 s und blinkt danach weiter 5 Je nach Parameter Schritt 3 und 4 wiederholen 6 CLR dr cken LRN und CLR erl schen GER TEPARAMETER Ger teparameter z B Aufst...

Page 3: ...wie oben mit Pr senzmelder PIR Unterst tzte EEP A5 07 01 02 03 A5 08 01 02 03 LRN Taste an PIR dr cken press LRN button on PIR Same function as above with occupancy sensor PIR Supported EEP A5 07 01 0...

Page 4: ...sschaltverz gerung 5 Min Verz gerungszeiten einstellbar siehe Tabelle 3 Ausschaltverz ge rung S20 Einschaltverz gerung S20 1 1 Taste 2x dr cken press push button 2x S20 Toilet fan Valid for a channel...

Page 5: ...ren 9 2 s dr cken press 2 s 8 Sendertaste 2x dr cken press trans mitter button 2x 0 Sendertaste 2x dr cken press trans mitter button 2x dr cken press Invert output AUSSCHALTVERZ GERUNG S01 S04 SWITCH...

Page 6: ...in 1 minute steps PULSDAUER IMPULSE Verz gerungszeit A x B A B time delay A x B 1 15 s in 1 Sekunden Schritten 8 2 s dr cken press 2 s 8 Sendertaste 2x dr cken press transmitter button 2x 1 15 Sender...

Page 7: ...anal 1 8 11 4BS Query 0x 00 00 nn 0B On 0x 00 64 nn 0C Off 0x 00 00 nn 0C nn 00 07 channel 1 8 VLD EEP D2 01 14 12 VLD EEP D2 01 14 R CKMELDUNGEN ZEITPUNKT FEEDBACK TRIGGER Keine R ckmeldung 15 2 s dr...

Page 8: ...wer output Switch contact Rated current Inductive load cos 0 6 Incandescent lamp Fluorescent lamp cos 0 9 C 140 F Schraubklemmen 4 mm Screw terminals Schutzart IP20 Protection class Thermosicherung Ja...