14
DM-R160-0427A (Rev 2)
www.omnexcontrols.com
call toll free: 1-800-663-8806
Testing the Transmitter / Receiver Communication
What is the status of
the lights of both the
transmitter and
receiver?
Transmitter:
Active light is flashing
Receiver:
Status—GREEN
Link—Flashing GREEN
Fault—OFF
E-Stop—GREEN
Transmitter:
Active light is flashing
Receiver:
Status—GREEN
Link—RED
Fault—OFF
E-Stop—RED
There is no link between the
transmitter and receiver
Do you have a
matched set? (i.e. the
transmitter and re-
ceiver should have
identical ID codes
YES
NO
Was the transmitter
accidentally swapped
with another one on
the job site?
Search the job site for
the correct transmitter.
POSSIBLY
Transmitter and receiver
should be working properly.
The problem may rest with
the machine instead of the
radio system
Call for service
Was it found?
Turn on the transmitter
to check if the units
function correctly. If
not, proceed to Chart 1
NO
YES
The transmitter
code may need to
be re-downloaded
to the receiver
NO
!!Caution!!
Note: Before you proceed with the Download ID procedure located on Page 7 & 8, great
care and caution must be adhered to. Also, refer to Chart #4 for Tips and Considerations.
If by accident, the transmitters have been switched with another unit, by downloading the
ID code to a new receiver, it is possible for the transmitter to operate 2 units at the same
time (if the original receiver unit is still on the job site). Therefore it must be
certain that the transmitter / receiver pair are the correct set.
Secondly, once the download procedure is completed, ensure all other units on the job site
are stopped. Test the operation of the newly configured set to ensure no other
machines on the site work with the same transmitter.
Once you are certain that the transmitter / receiver pair are a unique set, continue
normal operations.
Call for service.
Troubleshooting Guide (con’t)
Chart #3