background image

4. OMICRON 

Device Link

 will automatically find and display your 

OTMC 100

.

The vertical bar on the left displays the device status:

Green bar: The device is online and ready for operation.

Gray bar: The device is offline. Connect your 

OTMC 100

 to the Ethernet network. If the

network is not able to supply your 

OTMC 100

 via PoE (Power over Ethernet), use a PoE

injector to supply your 

OTMC 100

 with power.

Red bar: The device is online but not accessible due to incorrect IP configuration.

OTMC 100

 is usually configured to obtain the IP address automatically. However, it is also

possible to assign a static IP address to your 

OTMC 100

. In this case, the following behavior

applies:
When accessing 

OTMC 100

 via Ethernet, OMICRON 

Device Link

 will find your 

OTMC 100

, but

display a red bar to indicate that the device cannot be accessed.

► Click the 

OTMC 100

 entry and select 

Configure IP

.

OMICRON 

Device Link

 will then display an IP configuration page. In this page, select 

Use the

following IP address

 and enter the IP address of your 

OTMC 100

, or enter an IP address of

your choice to assign a new IP adress to your 

OTMC 100

. Click the 

Subnet mask

 field to

automatically fill a subnet mask and then click 

Apply

 to connect to your 

OTMC 100

.

Or

► Click the 

Add device

 button and enter the IP address assigned to your 

OTMC 100

.

Accessing OTMC 100 from a Computer

OMICRON

15

Summary of Contents for OTMC 100

Page 1: ...Smart Measurement Solutions OTMC 100 Quick Start Guide...

Page 2: ...user manual The user is responsible for every application described in this user manual and its results OMICRON electronics explicitly exonerates itself from all liability for mistakes in this manual...

Page 3: ...tions 8 3 3 Mounting instructions 10 3 3 1 Mounting instructions for mast mounting 10 4 Connecting OTMC 100 to an Ethernet network 12 5 Accessing OTMC 100 from a Computer 14 5 1 System requirements 14...

Page 4: ...00 series products can be used as a PTP Precision Time Protocol grandmaster clock according to the IEEE 1588 2008 standard and as an NTP Network Time Protocol time server for NTPv4 compliant equipment...

Page 5: ...wer over Ethernet power supplies Always use the waterproof RJ45 Ethernet connector supplied with OTMC 100 in order to maintain the watertightness of the device Do not use OTMC 100 outdoors without a w...

Page 6: ...ltage is provided via Ethernet PoE The LED indicates the device status LED continuously off OTMC 100 is not supplied with power via the RJ45 Ethernet connector see Troubleshooting on page 18 LED light...

Page 7: ...mbrane vent detached Pushbutton LED Pushbutton The pushbutton can be used to Initiate a factory reset to reset the device configuration to the factory defaults see Troubleshooting on page 18 Initiate...

Page 8: ...ion regulations and the protection concept of the building and the electrical installation may require a suitable surge protection device for the Ethernet network cable leading into the building For o...

Page 9: ...late to the top 2 BAD position Will not work properly BEST position Recommended Possible if no alternative position is available Not recommended Possible position Mount in an upright position OTMC 100...

Page 10: ...owing parts 1 mast clamp consisting of 2 clamping jaws and 4 fastening screws M6 x 110 with lock washers 2 clamping blocks and 4 fastening screws M6 x 16 with lock washers 1 connection pipe 20 x 300 m...

Page 11: ...ly with a tightening torque of 5 Nm Assemble the delivered waterproof RJ45 connector to the Ethernet cable according to the accompanying assembly instructions and insert it to the RJ45 connector on th...

Page 12: ...ntional RJ45 connector for test purposes only break off the locking tab at the RJ45 connector before inserting it to OTMC 100 OTMC 100 is supplied with power by Power over Ethernet PoE according to IE...

Page 13: ...tection device Ethernet network port not providing PoE PoE injector Surge protection device Mains The following figure shows a typical network with one OTMC 100 a network switch providing transparent...

Page 14: ...or higher If you are accessing OTMC 100 from a Mac or Linux operating system supporting zeroconf you can access the web interface of OTMC 100 by entering http hostname local to the address bar of you...

Page 15: ...ble to assign a static IP address to your OTMC 100 In this case the following behavior applies When accessing OTMC 100 via Ethernet OMICRON Device Link will find your OTMC 100 but display a red bar to...

Page 16: ...b interface 6 The web interface is opened in a web browser Password protection is disabled by default If a password has been defined for your OTMC 100 a login dialog is displayed Enter your password a...

Page 17: ...100 Series User Manual provides an overview of steps required to configure OTMC 100 according to your needs Clicking Manual in the top right corner of the web interface displays the OTMC 100 Series U...

Page 18: ...ontinuously off OTMC 100 is not supplied with power via the RJ45 Ethernet connector due to one of the following reasons The network port OTMC 100 is connected to does not provide Power over Ethernet P...

Page 19: ...essed after unscrewing the water tight membrane vent Use a pointed tool such as a ball pen to press the pushbutton see figure on page 18 NOTICE Ingressing water may cause equipment damage Do not forge...

Page 20: ...licenses To view the license information on the Open Source software used in OTMC 100 please launch the OTMC 100 web interface and click the License Information hyperlink in the bottom right corner Th...

Page 21: ...ing support is one of our top priorities At our technical support hotline you can reach well educated technicians for all of your questions Around the clock competent and free of charge Make use of ou...

Page 22: ...ENU 1066 03 01...

Reviews: