omi PRE 15 Use And Maintenance Manual Download Page 15

Cod. 710.0048.31.01  – Rev.1A  – 02.2018 

ENGLISH

 

11 / 30 

 
2.2 STORAGE AND INSTALLATION LOCATION 

If not in use, the refrigerator can be stored in its packaging in a dust free and protected site between 0°C and 50 °C, and 
a specific humidity not exceeding 90 %. Should the stocking time exceed 12 months, please contact your local authorized 
distributor. 

 

 

If the refrigerator is not used, it will be placed in a site with the following conditions: 

 

The machine must be protected from atmospheric agents and not directly exposed to sun light. 

A seating base flat and capable to hold the weight of the machine. 

Ambient temperature complying with the nominal data of the refrigerator. 

The refrigerator should be located in a clean area, without forced air draft that can affect the fan control system. 

Make  sure  to  leave  sufficient  clearance  (20  inches,  500  mm)  around  the  refrigerator  in  order  to  allow  an 
adequate cooling of the machine and for maintenance and/or control operations.

 

 

The incoming gas must be free from smoke or flammable vapours which could lead to explosion or 
fire risks. 

2.3 UNPACKING 

The packaging is made of carton or of cellophane. We recommend that you keep the original packaging for the device 
in case it has to be transported to another location or sent to a service center. Dispose the various packaging materials 
in compliance with the relevant rules locally in force. 

 

 

unpack the device, removing the strapping from the carton. Always wear safety gloves when using scissors or other 
tools to cut the straps or the cellophane; 

 

remove the carton or the cellophane; 

 

in case it’s necessary another handling of the device, refer to section 2.1; 

 

remove the pallet (if present); 

 

remove the operating manual, accessories and key from the device. 

2.4 INSTALLATION 

 

 

 

 

 

Before attempting any installation operation, make sure that 

 

No parts of the nitrogen system are under pressure. 

 

No parts of the system are electrically powered. 

 

Tubing to be connected to the refrigerator are free of impurities. 

 

The pipes to be connected to the refrigerator does not weigh on the device. 

 

All interconnecting piping has been tightened. 

After having verified the points listed above, you can proceed to the installation of the machine. 

1.  Connect the refrigerator to the compressed nitrogen lines. If not already existing, we suggest to install 

a  by-pass  allowing  to  isolate  the  machine  from  the  plant,  thus  to  facilitate  eventual  maintenance 
operations. 

2.  Perform the electrical connection in accordance with any local laws and regulations after reviewing the 

refrigerator electrical specifications and wiring diagram. 

3.  Power the refrigerator after having checked that the nominal voltage and line frequency are constant 

and matching the nominal values of the machine. The user must provide the installation with an 
adequate  line  protection  and  a  ground  terminal  complying  with  the  electrical  rules  locally  in 
force.
 

 
 
 
 
 
 
 
 

Summary of Contents for PRE 15

Page 1: ...2018 IT REFRIGERATORE PER AZOTO COMPRESSO EN COMPRESSED NITROGEN REFRIGERATOR ES REFRIGERADOR PARA NITR GENO COMPRIMIDO Manuale d uso e manutenzione Use and maintenance manual Manual de uso y manteni...

Page 2: ......

Page 3: ...ng 11 2 4 Installation 11 3 START UP 3 1 Before Start Up 12 3 2 Start Up 12 3 3 Control panel 13 3 4 Display indication 14 3 5 Remote signalling alarm 14 4 MAINTENANCE TROUBLESHOOTING AND DISMANTLING...

Page 4: ......

Page 5: ...o ed garantito secondo le condizioni riportate sul listino di vendita e o sul contratto di fornitura SIMBOLOGIE UTILIZZATE NEL MANUALE E SUL REFRIGERATORE Punto ingresso azoto Punto uscita azoto Legge...

Page 6: ...nque parte della macchina senza prima togliere pressione dall impianto 6 Non cercare di rimuovere una qualunque parte del circuito frigorifero senza prima rimuovere il refrigerante e predisporne il co...

Page 7: ...sempre i guanti se si utilizzano forbici o cesoie per tagliare le reggette od il cellophane Togliere la scatola di cartone o l involucro in cellophane Se necessaria un ulteriore movimentazione della...

Page 8: ...A IN FUNZIONE 3 1 PRELIMINARI DI AVVIAMENTO Prima di avviare la macchina accertarsi che tutti i parametri di funzionamento siano conformi ai dati di targa Il refrigeratore viene fornito gi collaudato...

Page 9: ...medio alto La macchina nello stato di ON e il carico alto 3 3 1 FUNZIONE DEI TASTI SET premuto e rilasciato durante il normale funzionamento visualizza il parametro si set point C1 DOWN mantenuto in...

Page 10: ...mmediato PF1 Interruzione o corto circuito della linea di ingresso della sonda PTC Uscita allarme attiva Uscita compressore non attiva Uscita ventilatore non attiva Uscita scarico standard Resettabile...

Page 11: ...i ed eventuali interventi di verifica e o manutenzione devono essere eseguiti da personale qualificato Contattare un tecnico frigorista per qualsiasi intervento sul circuito frigorifero della macchina...

Page 12: ...tituirla Controllare la scheda elettronica se il problema persiste sostituirle Contattare il nostro Centro Assistenza per controllare la carica del gas Blocco Controllare se l ingresso e l uscita dell...

Page 13: ...ce WARRANTY Each product is delivered regularly tested and covered by the warranty conditions specified on the sales list and or on the supply contract SYMBOLS USED IN THE MANUAL AND ON THE REFRIGERAT...

Page 14: ...empt to service any part while machine is in an operational mode 5 Do not attempt to remove any parts without first relieving the entire nitrogen system of pressure 6 Do not attempt to remove any part...

Page 15: ...e relevant rules locally in force unpack the device removing the strapping from the carton Always wear safety gloves when using scissors or other tools to cut the straps or the cellophane remove the c...

Page 16: ...START UP 3 1 BEFORE START UP Before starting the machine make sure that all operating parameters correspond to the nominal data The refrigerator is supplied already tested and preset for normal operat...

Page 17: ...load 3 3 1 KEYS FUNCTION SET When pushed and released during normal operation it displays the set point parameter C1 DOWN When pushed and released during normal operation it displays the set point pa...

Page 18: ...your local distributor Ht2 Very high dew point value immediate alarm PF1 Interruption or short circuit on the PTC probe input line Alarm output ON Refrig Compressor output OFF Fan output OFF Drain cy...

Page 19: ...ting and eventual control and or maintenance operations must be performed by qualified personnel For maintaining the refrigerating circuit of the machine contact a refrigeration engineer TROUBLE DISPL...

Page 20: ...probe if the trouble persists replace it Check the electronic control board if the trouble persists replace it Contact our distributor to check the gas charge Clog Check if the compressed gas inlet o...

Page 21: ...armente probado y est garantizado seg n las condiciones detalladas en la lista de venta y o en el contrato de suministro SIMBOLOG AS UTILIZADAS EN EL MANUAL Y EN EL REFRIGERADOR Punto de entrada nitr...

Page 22: ...a est en funcionamiento 5 No intente retirar ninguna parte de la m quina sin antes quitarle presi n al equipo 6 No intente apartar ninguna parte del circuito de refrigeraci n sin antes quitar el refri...

Page 23: ...lice tijeras u otras herramientas para cortar los flejes o el celof n Retire el cart n o el celof n En caso de que sea necesario manipular adicionalmente el dispositivo consulte la secci n 2 1 Retire...

Page 24: ...Antes de arrancar la m quina cerci rese que todos los par metros de funcionamiento est n conformes a los datos de chapa El refrigerador es suministrado ya probado y pre regulado para un normal funcion...

Page 25: ...ales Si la m quina est en la condici n de ON y la capacidad y la temperatura de aire son medio altas Si la m quina est en la condici n de ON y la capacidad y la temperatura de aire son altas 3 3 1 FUN...

Page 26: ...rcuito de la l nea de entrada de la sonda PTC Salida de alarma activa Salida de compresor no activa Salida de ventilador no activa Salida de descarga standard Se puede restablecer si se apaga el refri...

Page 27: ...ventuales operaciones de verificaci n y o mantenimiento deben ser ejecutadas por personal calificado Contacte a un t cnico frigorista para cualquier operaci n en el circuito refrigerante de la m quina...

Page 28: ...siste sustit yala P ngase en contacto con su distribuidor para controlar la carga del gas Bloque Compruebe que la entrada y la salida del nitr geno comprimido est n conectadas correctamente Verifique...

Page 29: ...CRIPTION ES DESCRIPCI N POS Compressore Compressor Compresor 1 Condensatore Condenser Condensador 2 Ventilatore Ventilator Motor Ventilador 3 Evaporatore Evaporator Evaporador 4 Valvola di espansione...

Page 30: ...Cod 710 0048 31 01 Rev 1A 02 2018 A 26 30 PRE 150 713 0069 01 01 Rev 00...

Page 31: ...sore Compressor Compresor 1M1 Ventilatore Ventilator Motor Ventilador 1M2 Scheda elettronica Electronic Board Controlador electr nico 1A1 Pressostato ventilatore Ventilator pressure Switch Presostato...

Page 32: ...o m ximo KW 0 243 0 371 0 627 0 732 0 79 0 94 Assorbimento nominale Nominal current Absorci n nominal A 1 13 1 46 3 20 3 29 4 60 4 70 Assorbimento pieno carico Full load current Absorci n plena carga...

Page 33: ...Cod 710 0048 31 01 Rev 1A 02 2018 C 29 30 PRE 70 COOLING AIR FLOW COOLING AIR FLOW PFL 150 COOLING AIR FLOW COOLING AIR FLOW...

Page 34: ...ventilatore Fan motor Motor ventilador 1M2 210 0121 01 00 210 0123 01 00 210 0126 00 00 Griglia Grid Rejilla G Ventola premente Pusher ventilator Ventilador impelente VT Scambiatore di calore Heat ex...

Page 35: ......