RhinoBond Owner’s Manual

  Page 3

   

Seam M

ode

OFF                    O

n

Device Ready

Mode

OptiW

eld

Membr

ane

PVC 60 mil

Activations 

Today

                          0 

THE RHINOBOND SYSTEM

Heat Sinks  

(6 included with a 

carrying case)

Activation 

Button

Touchscreen 

Display

Power Cord

Height 

Adjustment 

for Handle

Induction 

Coil

Handle

RhinoBond 

with

 OptiWeld Tool 

with carrying case

READ & UNDERSTAND

 all operating instructions before 

using this tool.

DO NOT USE THIS TOOL

 if you have (or anyone near you has) 

pacemaker, surgical implant, prosthesis or other med-

ical device.

 The RhinoBond tool may interfere with proper 

medical device operation.

DO NOT activate tool over metal objects in/on the floor.

DO NOT use the cord to carry the tool.

UNPLUG THE CORD before attempting to inspect or clean the 
tool, or you risk electric shock.

DO NOT

 activate tool over the power cord.

KEEP CORD AWAY FROM

 heat, liquids, sharp edges and 

moving parts.

STAY ALERT.

 Do not use this tool when tired or under the 

influence of drugs, alcohol or medication that can alter your 
awareness.

3"

75mm

DO NOT 

allow any object containing metal, such as keys, 

jewelry, watches etc., within 3 inches (75mm) of the bottom of 
the tool during use.

IF CORD IS DAMAGED,

 immediately discontinue using the 

tool and contact OMG Roofing Products at 800.633.3800 for 
repair.

DO NOT

 operate the RhinoBond tool during periods of rain or 

in wet conditions. Keep the tool dry at all times.

ALWAYS ENSURE

 that the tool is properly grounded (CFCI 

Circuits are best) and that power is from a safe and reliable 
source.

ALWAYS WEAR 

proper personal protective equipment when 

working on a roof.

 SAFETY

 

Read and Understand all Instructions. Keep this manual for later reference. 
INTENDED USE
The RhinoBond System

 is intended for installing thermoplastic (i.e. TPO and 

PVC) and “Clean EPDM” roofing membranes on commercial, industrial, institu-

tional and appropriate residential roofs.  Its sole purpose is to bond, by induction 

means, the bottom side of the roofing membrane to a washer or plate installed 

to hold insulation and other roofing components in place, and serve as an attach-

ment point for the induction welding process. Only fasteners, washers and tubes 

provided by OMG Roofing Products are approved for use with the RhinoBond 

System. 

The RhinoBond System produces heat that can seriously injure people 

and damage metal objects.

 Please be sure that you and all crew members 

read and understand the instructions in this manual before attempting to use 

the RhinoBond System. Failure to follow all instructions could result in 

property 

damage, serious personal injury, electric shock or death.

This appliance is not intended for use by persons with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the appliance by a person 

responsible for their safety. Keep this tool out of the reach of children.

Summary of Contents for RBT007

Page 1: ...v 06252020 153 BOWLES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM Non penetrating fastening system for commercial roofing IMPORTANT Save this manual and read it in full before use...

Page 2: ...le easy to use system that secures membrane to roofing substrates using micropro cessor controlled induction welding Roofing installed this way has several benefits Fewer Fasteners RhinoBond requires...

Page 3: ...conditions Keep the tool dry at all times ALWAYS ENSURE that the tool is properly grounded CFCI Circuits are best and that power is from a safe and reliable source ALWAYS WEAR proper personal protecti...

Page 4: ...z 220V 50Hz EXTENSION CORD 12 gauge min 100 ft max 110V 2 5mm X 30m 16A 230V 3x15 30m 10A 30m PORTABLE GENERATOR POWER SOURCE 5 000W min with 2 20A GFCI Circuits 2 5 KVA min with 16Amp 110V protected...

Page 5: ...s under each plate to protect the insulation from melting On foil faced insulation the recommended minimum cover board is 1 in 38 mm Metal Deck A minimum of 1 inches 38 mm of insulation over a metal d...

Page 6: ...progress If necessary you can calibrate the touch screen at this time To do so touch this screen once to begin the calibration process see below Once startup is complete the screen will display the L...

Page 7: ...es can be reviewed Power Display The Power Display shows the line voltage the tool is receiving from the power source The tool requires a minimum of 100 volts to operate effectively Menu Pressing this...

Page 8: ...ce of membrane from the project weld each plate and apply a magnetic heat sink to each Allow plates to cool to the touch approx 5 minutes before removing the magnetic heat sinks Turn the membrane over...

Page 9: ...gy Level setting push the plus or minus buttons Push the Home button once the energy setting is set The screen will automatically return to the Device Ready screen The Device Ready screen will display...

Page 10: ...gnetic cooling clamp on the plate and mark the energy setting on the membrane for reference Adjust the Energy Level to the next higher setting and repeat the test weld process until all five plates ar...

Page 11: ...arrow to return to the previous screen Press the Sound button to change the Activation Complete tone The sound can be enabled by press ing the On button and disabled by pressing the Off button You ha...

Page 12: ...t factory reset Press the Home button to return to the Device Ready screen Press the back arrow to return to the previous screen From the main Menu press the Help button to access OMG Roofing Products...

Page 13: ...main Menu press the Help button to review the Troubleshooting tips and error message descriptions Press any of the error message buttons to get more information and recommendations Press the back arro...

Page 14: ...Voltage Directive LVD 2006 95 EC The following harmonized standards were applied LVD EN60335 1 2012 A11 2014 EN60335 2 45 2002 A2 2012 RhinoBond Induction Welding Tools wielding the CE Mark comply wi...

Page 15: ...RhinoBond Owner s Manual Page 15 NOTES...

Page 16: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...

Reviews: