background image

RhinoBond Owner’s Manual

  Page 2

 

THE RHINOBOND SYSTEM WARRANTY 

Guaranteed for 200,000 cycles of operation, or three years from date of purchase, 

whichever comes first. 

During this period OMG, Inc., at its option, will repair or replace 

any tool for the roofing contractor who originally purchased the tool. This will be done 
free of charge, provided the tool is determined defective in materials or workmanship 
upon examination by an Authorized RhinoBond System Service Technician. 
This Warranty will be honored only if: 

A.  No evidence of abuse, misuse or failure to follow safety or operating instructions, or 

improper modification of the tool, is present. (Read this Owner’s Manual for safe use 
and proper operating instructions.) 

B.  When replacement is necessary, the first end-user returns the tool with transportation 

prepaid, to the nearest Authorized RhinoBond System Service Technician with 
purchase receipt or other positive proof of purchase. 

C.  Only genuine RhinoBond tool, fasteners, and plates are used in the application. 

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER 
WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESS OR IMPLIED, INCLUDING BUT NOT 
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE SHALL NOT APPLY. THESE OTHER EXPRESS OR IMPLIED WARRANTIES 
ARE SPECIFICALLY EXCLUDED. BUYER’S OR USER’S REMEDIES ARE SOLELY AND EXCLUSIVELY 
AS STATED HEREIN. OMG, INC. SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL, 
CONSEQUENTIAL, INDIRECT OR SPECIAL DAMAGES RESULTING FROM FAILURE OF THIS 
WARRANTY. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY, 
TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL OMG, INC.’S LIABILITY TO THE 
BUYER OR USER OF THE TOOL OR ANY LOSS OR DAMAGE ARISING OUT OF THE BREACH 
OF WARRANTY, CONTRACT OR TORT, EXCEED THE PURCHASE PRICE HEREIN. ANY CLAIM 
OR LIABILITY SHALL IN ANY EVENT TERMINATE UPON THE EXPIRATION OF THE WARRANTY 
PERIOD SPECIFIED ABOVE.

For RhinoBond Tool Service: 800.633.3800

ROOFTOP SAFETY

 

In addition to the safety instructions in this manual, OMG Roofing Products recommends that all roof top workers follow the safety  

guidelines outlined in the OSHA booklet called "Protecting Roofing Workers" available at 

www.osha.gov/Publications/OSHA3755.pdf 

and or EU-OSHA “Directive 92/57/EEC - Temporary or mobile construction sites,” as applicable.

INTRODUCING THE RHINOBOND

®

 SYSTEM

Congratulations! 

The RhinoBond System is one of the industry’s most advanced fastening systems for 

installing thermoplastic membrane roofing and, in Europe only, “approved” clean EPDM membrane*.  

RhinoBond is a portable, easy-to-use, system that secures membrane to roofing substrates using micropro-

cessor-controlled induction welding. 
Roofing installed this way has 

several benefits:

•  Fewer Fasteners -- 

RhinoBond requires 25-50% fewer fasteners vs. mechanical attachment to meet FM  

      1-90 and Eurocode National wind uplift requirements.

•  Zero Penetrations – 

The fasteners and plates used are all installed under the membrane, so with  

      RhinoBond there are no membrane penetrations or potential points of entry for moisture.

•  Less Seaming – 

RhinoBond does not require any half-sheets, just full width membrane everywhere. This  

      can eliminate up to 30% of the seams when compared to a traditional mechanically attached system. 

•  Superior Wind Performance – 

The RhinoBond System has higher wind uplift resistance with fewer  

      fasteners and fewer seams when compared to mechanically attached roofs.
The RhinoBond system uses powerful induction technology to create a strong bond between the roofing 

membrane and fastening plates. The technology that makes this possible, SINCH

®

 Technology, is a compact 

microprocessor-controlled electromagnetic induction bonding process. Today, this rugged technology is being 

used to revolutionize industrial and consumer applications. 
While RhinoBond is a safe, tested tool, we caution you to be sure that every member of your crew has a 

thorough understanding of the RhinoBond System before attempting to use it. Read, understand and follow 

all instructions. 

Congratulations on your new purchase. 

We look forward to your feedback. Please send us your 

comments and suggestions at any time.

RhinoBond Team 

OMG Roofing Products  |  [email protected] 

800.633.3800 | 413.789.0252 | www.rhinobond.com

*Clean EPDM Membrane -- currently there are a limited number of clean EPDM options available only in Europe and approved for 
use with RhinoBond. Always verify membrane suitability and approvals with membrane supplier. RhinoBond is not suitable for use 
with other EPDM membrane.
© Copyright 2020 OMG, Inc. All rights reserved.

RhinoBond

®

 and 

SINCH Technology

®

 are registered trademarks, 

OptiWeld

™ 

is

 

a trademark of OMG, Inc., a leading provider of 

innovative  fastening solutions and products for the construction industry.

PATENT NOTICE:

 U.S. Patent Nos. 6,710,314; 6,849,837; 7,399,949; 8,492,683; 8,933,379. Canadian Patent Nos. 2,458,353; 

2,602,753. U.S. Patent Pending.
Contact OMG Roofing Products or your roofing membrane manufacturer for the most current list of approvals.

TABLE OF CONTENTS

  3  RhinoBond Tool & System Description

 

  System 

Components 

    Power Requirements Chart

  3  Safety Instructions

  4  Operating Instructions 

  Power Requirements

  6  Tool Operation 

  

Display Functions 

  Menu 

Options/Features 

  Error 

Messages

  7  Automatic Calibration

  8  Manual Calibration

 10  Menu  Settings

 12  Troubleshooting

 13  EC Declaration of Conformity

Summary of Contents for RBT007

Page 1: ...v 06252020 153 BOWLES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM Non penetrating fastening system for commercial roofing IMPORTANT Save this manual and read it in full before use...

Page 2: ...le easy to use system that secures membrane to roofing substrates using micropro cessor controlled induction welding Roofing installed this way has several benefits Fewer Fasteners RhinoBond requires...

Page 3: ...conditions Keep the tool dry at all times ALWAYS ENSURE that the tool is properly grounded CFCI Circuits are best and that power is from a safe and reliable source ALWAYS WEAR proper personal protecti...

Page 4: ...z 220V 50Hz EXTENSION CORD 12 gauge min 100 ft max 110V 2 5mm X 30m 16A 230V 3x15 30m 10A 30m PORTABLE GENERATOR POWER SOURCE 5 000W min with 2 20A GFCI Circuits 2 5 KVA min with 16Amp 110V protected...

Page 5: ...s under each plate to protect the insulation from melting On foil faced insulation the recommended minimum cover board is 1 in 38 mm Metal Deck A minimum of 1 inches 38 mm of insulation over a metal d...

Page 6: ...progress If necessary you can calibrate the touch screen at this time To do so touch this screen once to begin the calibration process see below Once startup is complete the screen will display the L...

Page 7: ...es can be reviewed Power Display The Power Display shows the line voltage the tool is receiving from the power source The tool requires a minimum of 100 volts to operate effectively Menu Pressing this...

Page 8: ...ce of membrane from the project weld each plate and apply a magnetic heat sink to each Allow plates to cool to the touch approx 5 minutes before removing the magnetic heat sinks Turn the membrane over...

Page 9: ...gy Level setting push the plus or minus buttons Push the Home button once the energy setting is set The screen will automatically return to the Device Ready screen The Device Ready screen will display...

Page 10: ...gnetic cooling clamp on the plate and mark the energy setting on the membrane for reference Adjust the Energy Level to the next higher setting and repeat the test weld process until all five plates ar...

Page 11: ...arrow to return to the previous screen Press the Sound button to change the Activation Complete tone The sound can be enabled by press ing the On button and disabled by pressing the Off button You ha...

Page 12: ...t factory reset Press the Home button to return to the Device Ready screen Press the back arrow to return to the previous screen From the main Menu press the Help button to access OMG Roofing Products...

Page 13: ...main Menu press the Help button to review the Troubleshooting tips and error message descriptions Press any of the error message buttons to get more information and recommendations Press the back arro...

Page 14: ...Voltage Directive LVD 2006 95 EC The following harmonized standards were applied LVD EN60335 1 2012 A11 2014 EN60335 2 45 2002 A2 2012 RhinoBond Induction Welding Tools wielding the CE Mark comply wi...

Page 15: ...RhinoBond Owner s Manual Page 15 NOTES...

Page 16: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...

Reviews: