SECTION 12
TROUBLESHOOTING
99
|
OMEO EVOLUTION USER MANUAL
Non-critical Auxiliary Indicator Light warnings
Green Light constantly on, or
periodically flashing green
This is not an error code.
It indicates the battery is charging.
When the Auxiliary Batteries get close to full the Auxiliary Indicator Light will flash green.
However, once the Auxiliary Batteries are very close to 100% full, the Auxiliary Indicator Light will once again turn off, even
when plugged into AC power via the Auxiliary Battery Charger.
YELLOW pulse every 3 seconds
This indicates the Auxiliary Battery is discharged to less than 50%.
The Lights and USB Port will NOT function at this point.
NOTICE
This error can show briefly immediately right after raising or lowering Stabilising Legs, as this activity briefly
lowers the detected Battery capacity.
RED pulse every 1.5 seconds
This indicates the Auxiliary Battery levels are discharged to less than 20% and are too low for continuous operation.
Charge the Auxiliary Batteries as soon as possible.
There will be sufficient power to activate the Stabilising Legs several times immediately after the red light begins to flash.
However once the Batteries are fully discharged, there is no further signal, and the Stabilising Legs will no longer function.
Press the Main Control Switch for seven seconds to raise the Stabilising Legs if no other errors are present.
NOTICE
This error can also show briefly immediately after raising or lowering the Stabilising Legs, as this activity briefly
lowers the detected Auxiliary Battery capacity.
Flashes between white and blue,
yellow and blue, or red and blue
This indicates a Stabilising Leg jammed on the last attempt to raise the Stabilising Legs.
The Auxiliary Indicator Light pattern should only flash for 30 seconds after an attempt to raise the Stabilising Legs has
been made.
Table 10: Non-critical Auxiliary Indicator Light warnings.