Changing Filters 

Disposable 
 

·

  Prior to changing the filters, the water level in the tank must be no higher than the 

level of the spray bar.   

 

·

  Filters should be changed periodically depending on the usage of the equipment and 

the contaminants being removed. If water is not flowing more than a trickle from the 
spray bar holes, it is time to replace your filters.  

 

·

  Individually unscrew counterclockwise the two (2) large blue filter cartridge holders.  

The cartridges will be full of water.  

 

·

  Pour the water out of the cartridges and remove the filters.  Be careful not to lose the 

rubber O-ring gasket located on the inside of the filter cartridge.  Absence of this 
gasket will cause the filter(s) to leak.  

 

·

  Replace with new filter(s) and re-install the cartridges.  

  

·

  The 20 Micron Polycarbonate Filter is the primary filter and is located on the right 

side of the filtration unit.  

 

·

  The 10 Micron Polycarbonate Filter is the secondary filter and is located on the left 

side of the filtration system.  

 

 

Reusable Stainless Steel 
 

·

  Clean the outside of the filters in a sink.  

·

  Place each filter into individual Ziplock bags.  

·

  Fill each bag with hot water and add soap from the bath.  

·

  Seal bag and place into ultrasonic tank and operate the ultrasound for 15 minutes.  

·

  Dump the fluid from the bag into the sink, NOT the ultrasonic tank.  

·

  Repeat the process until no dirt is extracted from the filters.  

·

  Replace the filters into the blue canisters.  

**Note: Constant usage will cause filters to be changed out more often than the 

complimentary ultrasonic tank.** 

Summary of Contents for RESTORATION PRO 3600PW

Page 1: ...1 Omegasonics Pre Wash Cleaning Equipment Operation Instruction Manual RESTORATION PRO 3600PW Model OMG 3600PW 240 VAC 50 60 Hz Read all instructions thoroughly before operating this equipment...

Page 2: ...l Temperature 8 Filtration System 9 Cleaning Procedures 10 General Cleaning 10 Fire Restoration 10 Equipment Maintenance 11 General 11 Tank Draining 11 Changing Filters 12 Limited Warranty 13 Trouble...

Page 3: ...t prior to placing items into the Ultrasonic Tank for final precision cleaning An upper and lower spray bar to create a cyclonic action that removes gross contamination Omegasonics provides a complete...

Page 4: ...h 300 series stainless steel Do not use any chemicals that contain any strong acids i e hydrochloric sulfuric or muriatic acid These chemicals will cause permanent damage to the stainless steel welds...

Page 5: ...ng a heated deionized water source at the unit or an adjacent sink is a benefit when rinsing electrical electronic contents or contents that would show water spots General Place the machine on a level...

Page 6: ...of approximately 60 gallons when the water level is at the midpoint of the spray bar This liquid volume does not include the liquid in the pump filter system Use this volume for calculating the amoun...

Page 7: ...he lid towards yourself and close the lid over the tank to maximize insulation efficiency Set digital timer and temperature controls The OMG 3600PW utilizes 3 900 Watt built in silicone heating elemen...

Page 8: ...ariance This serves as a buffer to protect the life of the motor contactor AT ALM 2 Omegasonics use only Return Key Operation The temperature controller is factory set at 110 F To change the Set Value...

Page 9: ...en remove the contaminants pass the water through the dual filters primary secondary and spray the filtered water back into the wash tank through the spray bars The pump and heat circuits can be opera...

Page 10: ...ure of the solution the number of parts to be cleaned the amount of contamination and the amount and type of cleaning agent used Generally 3 to five 5 minutes is sufficient If items are heavily contam...

Page 11: ...he inside of the tank with a clean soft cloth Do not use steel wool cleaning pads as they are too abrasive and will scratch the tank surface Rinse the tank again If the tank will not be used for a lon...

Page 12: ...et will cause the filter s to leak Replace with new filter s and re install the cartridges The 20 Micron Polycarbonate Filter is the primary filter and is located on the right side of the filtration u...

Page 13: ...e the responsibility of the user This warranty does not include damage or product failure which results from cavitation erosion misuse abuse or transportation damage This warranty is limited to the or...

Page 14: ...facility power supply b Remove upper panel located on the right end of the machine c Look for the ice cube relay located at the left end of the back panel d Flip the window up window has a red button...

Page 15: ...w the filters are clogged and must be replaced 5 If you are using stainless steel reusable filters follow 5a 5g a Clean outside of filters in a sink b Place each filter into individual Ziplock bags c...

Page 16: ...manufactured after January 2015 have panel fuses and may be burnt If either of the fuse holder red lights are lit the 5 amp fuse s must be replaced Heat is causing the circuit breaker to trip 1 Likel...

Page 17: ...nspect the back panel wires for burnt or loose wires Burnt wires are typically caused by a loosened connection and must be replaced Float Sensor Heat Pump Fuse for Circuit Ice Cube Relay Contactor Fro...

Page 18: ...or Float Sensor Digital Temperature Controller Digital Temp 2 Position Selector Heat and Pump Switch 2 Position Selector Power Button Push Button Motor Contactor 2 Contactor 240 Heat Blanket 3 Heat Bl...