background image

Servicing North America:

USA:

One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford CT 06907-0047
TEL: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1
TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

TELEX: 996404   EASYLINK: 62968934   CABLE: OMEGA

Mexico:

En Espan˜ol: (001) 203-359-7803

e-mail: [email protected]

FAX: (001) 203-359-7807

[email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech Republic:

Rudé armády 1868, 733 01 Karviná 8
TEL: +420 (0)69 6311899

FAX: +420 (0)69 6311114

Toll Free: 0800-1-66342

e-mail: [email protected]

France:

9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400

FAX: +33 (0)130 699 120

Toll Free in France: 0800-4-06342
e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United Kingdom:

One Omega Drive, River Bend Technology Centre

ISO 9002 Certified

Northbank, Irlam, Manchester
M44 5BD United Kingdom 
TEL: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]

omega.com

®

®

OMEGAnet

®

Online Service 

Internet e-mail

www.omega.com [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that
apply. OMEGA is constantly pursuing certification of its products to the European New Approach
Directives. OMEGA will add the CE mark to every appropriate device upon certification.

The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts 
no liability for any errors it contains, and reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be used for, patient-connected applications.

Summary of Contents for WMS-16

Page 1: ...www omega com e mail info omega com omega com User sGuide WMS 16 Complete Weather Station Shop online at...

Page 2: ...e minute to sixty minutes This logged data can be retrieved for display or copied to a floppy or hard disk for permanent storage using the options available on the main menu When retrieved for viewing...

Page 3: ...this protection Temperature is sensed using a thermistor element whose resistance changes in response to temperature fluctuations Relative humidity is sensed by changes in the dielectric constant of...

Page 4: ...ntrol Module The control module should be located as close as possible to the computer that will be used to communicate with the WMS 16 RS 232 communications the communication protocol used with the W...

Page 5: ...e will be no backup power source A fully charged 12V 7 amp hour battery will run the WMS 16 for three to four days With the backup battery in place the WMS 16 will continue collecting and logging data...

Page 6: ...e WMS 16T A6 7 Wind Direction WMS 02 A7 Add sensor A delete sensor D or quit Q The instructions in Appendix 1 direct you through the enabling procedure for each type of sensor should any sensor that y...

Page 7: ...PEED 3 9mph peak windspeed 7 8mph during past 10 min DIRECTION WNW 299deg varying 48deg during past 10 min WINDCHILL 52F CURRENT TEMPERATURE 51 6F 0 2F change during past hour TODAY S HIGH LOW 53F at...

Page 8: ...cedure allows you to specify certain operational parameters that the WMS 16 uses in its calculations and on its display Run Station Setup when using the weather station for the first time After that i...

Page 9: ...6 Station Sensor configuration will appear If all of the sensors that you intend to use are shown as being configured then press Q and Enter If you wish to add or delete a sensor then Press A for add...

Page 10: ...ly blocks with a minimum retrievable block of one full day s data After selecting 3 from the main menu specify the number of hours of data to be retrieved The data will be displayed in the format show...

Page 11: ...9 32 0 00 0 02 01 15 31 2 9 4 5 292 57 1 0 0 61 29 31 0 00 0 02 01 15 32 2 1 4 2 266 57 2 0 0 61 29 31 0 00 0 02 01 15 33 3 1 4 2 292 57 2 0 0 62 29 31 0 00 0 02 01 15 34 3 8 5 1 267 57 2 0 0 61 29 31...

Page 12: ...ents of the memory is downloaded each time the Memory Download procedure is invoked The data transfer is a nondestructive readout The format of downloaded data is shown in Figure 9 Omega Base Station...

Page 13: ...hold Enter high threshold Enter on delay in seconds 0 1200 It is the time that the sensor value is in the alarm condition before the alarm switch activates Enter off delay in seconds 0 1200 It is the...

Page 14: ...ges in the as delivered setup Instructions for setting up the WMS 16 with the following sensors Wind Speed and Direction Connect the wind sensor s signal cable to the terminal strip on the back of the...

Page 15: ...the Sensor Input Channel menu select number 11 ANALOG INPUT A7 Then Press ENTER The Sensor Configuration menu appears and it will show Sensor type Model Input Calibration Wind Speed WS 01 02 P1 Wind...

Page 16: ...lect 5 Humidity From the Humidity Sensors menu select 1 25500504 U 40 Then press ENTER From the Sensor Input Channel select 8 A4 Then press ENTER The Sensor Configuration menu appears and it will show...

Page 17: ...s a two conductor cable Connect one conductor to a GROUND terminal and the other conductor to terminal P3 INITIALIZATION OF THE RAIN GAUGE Press EXC to get the MAIN MENU From the MAIN MENU press numbe...

Page 18: ...you do not want to add another sensor select Q You will be asked if you are sure that you want to erase memory If you have added or deleted a sensor select Y if not select N and press ENTER Installati...

Page 19: ...2 mph WMS 16 5E 0 5 mph Time Constant 2 seconds WIND DIRECTION Range 0 360 Resolution 1 Accuracy 3 TEMPERATURE Range 40 to 140 F Resolution 1 F Accuracy 1 F RELATIVE HUMIDITY Range 0 100 RH Accuracy...

Page 20: ...ket Rain Gauge 40 Cable WMS 16PE Power Supply 220 VAC WMS ENCL 16A NEMA 4X Enclosure Assembly includes mounting brackets 12V 7AH battery and 10 watt solar panel battery charger WMS ENCL 16B NEMA 4X En...

Page 21: ...city Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industria...

Page 22: ...130 621 400 FAX 33 0 130 699 120 Toll Free in France 0800 4 06342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll...

Page 23: ...not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is no...

Reviews: