15
From the Station Set Up menu press number 6. ADD OR REMOVE SENSORS. Then press Y, then ENTER.
From the Sensor Type Menu select number 4. Temperature. Then press
ENTER.
From the Temperature Sensors Menu select number 1. (WMS-16T). Then press ENTER.
The menu then asks: Enter temperature offset or press Q to quit. Press Q.
From the Sensor Input Channel Menu select number 9. A5. Then press ENTER.
If you intend to add another sensor select A.
If you do not want to add another sensor select Q.
You will be asked if you are sure that you want to erase memory. If you have added or deleted a sensor select Y
if not select N and press ENTER.
If you selected
A
A
@
to add the Relative Humidity Sensor then press Y, then ENTER.
From the Sensor Types menu select 5. (Humidity)
From the Humidity Sensors menu select 1. (25500504(U)/40). Then press ENTER
From the Sensor Input Channel select 8. (A4). Then press ENTER
The Sensor Configuration menu appears and it will show:
Sensor type Model Input Calibration
Humidity
WMS-16-PN A4
Temperature
WMS-16T A5
If you intend to add another sensor select A. If you do not want to add another sensor select Q.
You will be asked if you are sure that you want to erase memory. If you have added or deleted a sensor select Y
if not select N and press ENTER.
Barometric Pressure Installation
Connect the barometer cable to the terminal strip on the back of the control module. This sensor has a three
conductor cable. The RED wire is connected to a +12V terminal. The BLACK wire is connected to a GROUND
terminal and the GREEN wire is connected to terminal A2.
INITIALIZATION OF THE BAROMETER
Press EXC to get the MAIN MENU.
From the MAIN MENU press number 1. STATION SETUP.