Omega VSHYe Series Installation And Operation Manual Download Page 29

OMEGA-VSHYe.F-IOM-2108

 

 

27 

 

 

 

 

ERV Fan Data 

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

0.6

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

WHISPER* 

MODE

N/A

N/A

225

210

195

175

160

145

130

115

100

85

70

-

-

MED

350

340

335

325

315

305

295

285

275

265

255

245

235

HIGH

-

-

365

355

350

340

330

320

310

305

295

285

275

WHISPER* 

MODE

N/A

N/A

250

230

225

205

180

160

145

125

110

90

75

-

-

MED

460

450

445

440

430

425

415

405

395

385

375

365

355

HIGH

-

-

-

-

470

465

455

445

435

430

420

410

400

WHISPER* 

MODE

N/A

N/A

450

430

410

390

370

350

320

300

270

250

220

-

-

MED

-

-

550

540

520

505

485

470

450

430

410

390

375

HIGH

-

-

-

-

-

-

555

540

525

510

490

475

460

WHISPER* 

MODE

N/A

N/A

450

430

410

390

370

350

320

300

270

250

220

-

-

MED

640

620

610

595

580

565

555

540

525

510

490

475

460

HIGH

-

-

675

670

655

650

640

620

610

595

580

565

550

WHISPER* 

MODE

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

MED

880

860

840

820

800

780

750

720

700

670

650

625

600

HIGH

-

-

-

-

895

880

860

820

805

795

780

770

760

WHISPER* 

MODE

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

MED

1080

1060

1040

1010

990

970

950

930

900

880

860

840

820

HIGH

-

-

-

-

1110

1090

1070

1060

1040

1020

990

980

960

WHISPER* 

MODE

N/A

N/A

620

580

560

520

480

440

410

380

340

300

260

-

-

MED

1230

1200

1185

1170

1150

1130

1110

1095

1080

1055

1040

1020

1000

HIGH

1320

1290

1275

1260

1240

1225

1205

1190

1175

1160

1140

1120

1100

External Static Pressure (in w.g.)

900

750

600

450

375

300

220

1200

1010

820

630

530

460

350

Unit 
Size

EC Motor 

Speed

Minimum 

SCFM

Rated 
SCFM

030

050

040

080

060

120

100

Note: All airflow ratings are taken at lowest voltage rating of dual rating (ie. 208 volt).

 

Airflow ratings include resistance of dry coil, Return Air panel and clean MERV10 air filters. 

 

*Standard 

Whisper

” 

mode is Fan On, Compressor Off mode for constant fresh air circulation. LOW Fan Speed 

tap is not available with Whisper mode.

 

Notes: 

 

• 

All airflow ratings are taken at lowest voltage rating of dual rating (ie. 208 volt).

 

• 

ERV external static setting is based on exhaust duct run.

 

• 

ESP capability shown per fan.

 

• 

Recommended ERV fan speeds are field set to match duct static. Default factory settings may not match site conditions and 

requirements. 

 

• 

Watts includes both ERV fans.

 

• 

Internal Manual OA Slider Damper may be used to control OA introduction in the event of variable OA conditions (i.e. wind stack 

effect)

 

 

0.00

0.025

0.05

0.075

0.10

0.15

0.20

0.25

0.30

0.40

0.50

25% Speed @ 6 Watts

10 O'clock

43

34

28

22

18

12

-

-

-

-

-

37% Speed @ 13 Watts

11 O'clock

70

54

43

34

27

15

7

-

-

-

-

45% Speed @ 18 Watts

12 O'clock

85

67

55

44

35

23

15

-

-

-

-

57% Speed @ 30 Watts

1 O'clock

111

95

83

74

68

54

45

37

30

21

15

69% Speed @ 43 Watts

2 O'clock

139

124

114

106

104

91

82

73

63

53

44

82% Speed @ 61 Watts

3 O'clock

168

155

150

141

139

127

119

107

96

85

72

95% Speed @ 82 Watts

4 O'clock

187

172

166

157

156

145

137

124

115

105

91

ESP (External Static) inwg

% PWM Signal / Power

Potentiometer 

Dial Setting

ECM Fan Data 

Summary of Contents for VSHYe Series

Page 1: ...IOM VERTICAL STACKED HYBRID HEATING COOLING W INTEGRATED ERV HIGH EFFICIENCY HE MODEL VSHYe DEV F DOCUMENT RELEASE OMEGA VSHYe F IOM 2108 3325A Orlando Dr Mississauga ON L4V 1C5 T 905 670 2269 omega h...

Page 2: ...re 7 Cooling Season 7 Heating Season 7 Operating Limits 7 6 Chassis Installation 8 Installation of Fittings and Hoses 8 Chassis Install 8 7 Unit Start Up 9 Checklist 9 Initial Start Up 9 8 Controls 10...

Page 3: ...result in death of serious injury ALL FIELD WIRING MUST BE PER FORMED ONLY BY A QUALIFIED ELECTRICIAN All wiring must be in accord ance of with the manufacturer s specifications Wiring that is improp...

Page 4: ...x 8 8 x 14 10 x 14 12 x 12 VSHYe 050 1 1 4 14 x 8 8 x 14 10 x 16 14 x 12 VSHYe 060 1 1 2 14 x 8 8 x 14 10 x 16 14 x 12 VSHYe 080 2 18 x 8 8 x 18 14 x 18 14 x 14 VSHYe 100 2 1 2 18 x 8 8 x 18 14 x 20 1...

Page 5: ...e furnished with type L M copper Available 3 inch deep swage connections on same size piping Contractor to provide couplings where the piping is not swaged or for joining dissimilar piping sizes Use f...

Page 6: ...k Side Top with 1 1 2 duct flange 3 ERV Ports Bathroom Exhaust Exhaust Air Outside Air 4 Removable ERV core 5 Chassis HP shown 6 Chassis service cover panel 7 1 air filter 8 Acoustic return air R A pa...

Page 7: ...on nect switch The panel is removed by swinging out and lifting it off the support pegs The middle panel is a removable swing panel for ac cessing and servicing the ERV core sensors and fans The upper...

Page 8: ...o not allow stub outs to rest or contact the sheet metal opening Do not allow the risers to bottom out when installing into the swage FOR SHIPPED LOOSE RISER SHUT OFF VALVES Visually inspect riser stu...

Page 9: ...ubbles 3 Shut off the circulating pump and open all the drains and vents to completely drain the system 4 The riser system should be cleaned after the initial flush and flushed a second time to adequa...

Page 10: ...e Check chassis nameplate to verify chassis model matches cabinet model for compatibility 2 Align chassis with front of the cabinet and tilt chassis so that the back aligns with the cabinet rails 3 Sl...

Page 11: ...and condensate riser ___All ductwork and ERV connections are complete ___Clean filters are installed ___All cutting sanding drywalling patching work is complete ___Unit blower spins freely ___Thermost...

Page 12: ...fan speed Do not wire thermostat fan to G1 terminal Multi Fan Speed Thermostat Up to two fan speeds can be selected from a multi speed thermostat Connect two of the thermostat fan speeds to the G2 and...

Page 13: ...ts anytime a fan and compressor request are made to develop flow in the water coil Valve Closed Timer The valve closed timer of 1 minutes starts anytime a call for compressor is terminated to allow fo...

Page 14: ...lows ensure maximum efficiency The exhaust air fans should be calibrated on site during start up and commissioning for both high speed mode P1 and low speed mode P2 Use the ERV board mounted low LO SP...

Page 15: ...00 0 025 0 05 0 075 0 10 0 15 0 20 0 25 0 30 0 40 0 50 25 Speed 6 Watts 10 O clock 43 34 28 22 18 12 37 Speed 13 Watts 11 O clock 70 54 43 34 27 15 7 45 Speed 18 Watts 12 O clock 85 67 55 44 35 23 15...

Page 16: ...en up your internet browser i e Explorer Google Chrome and type in the following address 192 168 0 99 Direct to Laptop Method 1 To connect to the controller you will need the follow ing Ethernet cable...

Page 17: ...troubleshooting aid For example in the figure below the first line item indicates Y terminal was ener gized Y 1 when the Cooling CLG 1 and tripped on Low Pressure fault LP 0 Captured unit controller d...

Page 18: ...equate drain age and test for signs of impending blockages 3 Check that condensate alarm is operating correctly Alarm trips whenever water level rises above sen sor threshold and locks unit operation...

Page 19: ...oo cold Adjust Supply Loop temperature higher Cooling Inadequate GPM If auto shut off valve is installed check that control valve actuator opens during call for Heating Set valve to manual mode and re...

Page 20: ...Trips Red Blinking Low pressure alarm Soft Lock Out Red Solid Water loop discharge temperature too hot Non latching alarm Red Blinking Sensor open missing or close shorted Non latching alarm replace...

Page 21: ...s determined by facing front of the unit return air opening Riser Handing Configurations S Supply Riser C Condensate Riser R Return Riser 12 Typ 8 Typ 8 Typ S R Chassis 6 2 2 S R c R S Chassis 2 2 D...

Page 22: ...earance Height Slab Thickness 2 inch overlap Rounded up to 120 or 144 Omega supplies two standard riser lengths 120 10 and 144 12 to be field cut on site Omega does not supply extension tailpieces or...

Page 23: ...RA panels with supply grille apply gasket tape to supply grille throat to insert into unit sup ply discharge flange Acoustic ERV RA Panel Dimensional Drawing Acoustic ERV RA Panel Sizes A B C VSHYe 03...

Page 24: ...Cabinet Base Height Min 5 1 increments B BH G 1 Note Include flooring thickness underlayment and any concrete leveling as part of calculation Example If using a 6 baseboard with 1 Finished Flooring h...

Page 25: ...A OA BE OA BE 8 R S C EA Furring Covers A4 B4 C4 D4 Configurations A1 B1 C1 D1 are Mirrored Furring Covers A2 B2 C2 D2 Configurations A3 B3 C3 D3 are Mirrored A2 Shown A4 Shown Typ min 1 2 Screws x 6...

Page 26: ...ht from Base of Cabinet B 1 D Rough In Height from Base of Cabinet B 2 NOTES Center vertically and horizontally RA panel supply opening with unit front knockout supply discharge For optional RA panels...

Page 27: ...OMEGA VSHYe F IOM 2108 25 VHSYe Electrical Schematic ECM Fan...

Page 28: ...nce ECM w Whisper Mode Factory 6 Wire Thermostat Harness Whip Thermostat Wiring Detail Factory supplied 6 wire thermostat cable shown Whisper Mode standard on VSHYe units Jumper between R and G1 facto...

Page 29: ...0 1140 1120 1100 External Static Pressure in w g 900 750 600 450 375 300 220 1200 1010 820 630 530 460 350 Unit Size EC Motor Speed Minimum SCFM Rated SCFM 030 050 040 080 060 120 100 Note All airflow...

Page 30: ...cing valve see name plate for GPM rating Air Temperature Measure the difference in tem perature across air coil for measuring sensible capacity T LAT EAT Sensible Capacity Btuh T x CFM x 1 08 Entering...

Page 31: ...ctory Set confirm that settings have not been adjusted to non standard settings SW1 ERV Board Power Switch Set to ON ____ Yes No SW2 ERV Toggle Switch Set to Neutral Middle Position _____ Yes No Fan E...

Reviews: