background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.  Purchase Order number under which the product

was PURCHASED,

2.  Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems

relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1. Purchase Order number to cover the COST

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems

relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Summary of Contents for SP-016

Page 1: ...1 P a g e TM User sGuide Shop online at omega com e mail info omega com For latest product manuals www omegamanual info SP 016 Heat Flux Thermopile Smart Probe...

Page 2: ...nly Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only U S A Headquarters Tel 203 359 1660 e mail info omega com Fax 203 359 7700 The information contai...

Page 3: ...r 15 5 1 1 Heat Flux Measurement Types 15 5 1 2 Heat Flux Input Data Type Format 15 5 1 2 1 Data Type 16 5 1 2 2 Factory Calibrate 16 5 1 2 3 Sensor Writeable 16 5 1 2 4 Smart Sensor 16 5 1 3 Heat Flu...

Page 4: ...t 22 5 3 2 1 Data Type 22 5 3 2 2 Factory Calibrate 22 5 3 2 3 Sensor Writeable 22 5 3 2 4 Smart Sensor 22 5 3 3 DIO Input Configuration 22 5 3 3 1 Lock 23 5 3 3 2 Apply Scaling 23 5 3 3 3 Assigned 23...

Page 5: ...e as it contains important information relating to safety and EMC Failure to follow all the safety precautions may result in injury and or damage to your equipment The following labels identify inform...

Page 6: ...ports any single thermopile sensor input mV W m2 and an additional thermocouple input for temperature compensation The Layer N SP 016 features 2 configurable digital I O pins These can be used for a m...

Page 7: ...1 Connecting to SYNC Automatic Detect Once the SP 016 and Layer N Smart Interface are connected to your computer SYNC will automatically detect it and begin displaying temperature readings Note If yo...

Page 8: ...work enter the Network Address here The default network address is 1 for most devices Please refer to the manual of your Smart Interface for more information Note The default Device Address is 1 Devic...

Page 9: ...sensitivity calculated as S ToC TempCoGain ToC TempCoOffset SCalib ToC is the measured temperature from the T type thermocouple From the HFS 05 datasheet HFS 01 Value Description TempCoGain 0 000334 T...

Page 10: ...onfiguration tab on SYNC and choose an input type that includes TC from the Type dropdown Step 2 Click the input you wish to configure and select your thermocouple type from the Device Range Type drop...

Page 11: ...nt However for increased accuracy Cold Junction Calibration can be performed as described below Step 1 Ensure your thermocouple has been configured in the previous section and click Calibration beneat...

Page 12: ...outputs setting in the Output Tab and assign the output to an alarm using SYNC For more information on how to set an alarm refer to section 4 6 3 Setting Alarms Output options are set in the Output T...

Page 13: ...can select between the following settings Option Value Description Rate 100 Hz Signal has a constant 100 Hz frequency with 0 100 Duty Cycle 10 Hz Signal has a constant 10 Hz frequency with 0 100 Duty...

Page 14: ...the Output Configuration Tab in SYNC and click on the icon located to the right of the available outputs Clicking the icon will open Define ON OFF Control dialog box as seen below Choose the input wit...

Page 15: ...gs Each enumerated Sensor has a Descriptor Base address location and a Sensor IPSO Configuration structure address location based on the sensor mix selected Sensor Descriptor Base IPSO Configuration E...

Page 16: ...Range Type 0 Internal Use Only 5 1 3 1 Apply Scaling For more information on Gain and Offset refer to the Smart Sensor Manual If set the user defined Offset and Gain values will be used to adjust the...

Page 17: ...e may be entered and the SP 016 will save the difference between the current measured value and the Target Value as the Calibration value The User Calibration may be used when the sensor is measuring...

Page 18: ...set until the calibration process is complete Setting the Calibration Reset bit will clear the calculated Offset value 5 2 Thermocouple Descriptor The Thermocouple Input interface provides interfaces...

Page 19: ...calibration values 5 2 2 3 Sensor Writeable The writable bit is cleared indicating that the sensor values may not be overwritten 5 2 2 4 Smart Sensor Refer to the Smart Sensor Device Interface docume...

Page 20: ...e User Calibration Parameter The SP 016 provides a Thermocouple User Calibration register that may be set while the device is in the User Calibrate mode and that is used to adjust the Cold Junction Co...

Page 21: ...0 1768 B 640 1820 C 0 2320 0x14 Max Range 5 2 6 1 Sensor Trigger Function The Sensor Trigger function is used to reset the IPSO min max values as well as control the ICE Point Single Point Calibration...

Page 22: ...ype Format DIO Data Type 7 6 5 4 3 2 1 0 Smart Sensor Sensor Writable Factory Calibrate Reserved Data Type 0 0 0 0 6 Floating point Note Please refer to the Smart Sensor Interface Technical Guide for...

Page 23: ...figuration allows enabling each of the 2 input bits and selecting whether the input is active HIGH or active LOW If the Invert Bit is set the signal will be Active Low DIO Device Configuration 7 6 5 4...

Page 24: ...DIO inputs and all bits should be written as 0 5 3 6 DIO Input Circuitry The DIO input circuitry shares the output circuitry The internal processor drives the Output Control signal to turn on the outp...

Page 25: ...equency 100 msec repetition rate with 0 100 duty cycle 2 1 Hz PWM signal has a constant 1 Hertz frequency 1 second repetition rate with 0 100 duty cycle 3 0 1 Hz PWM signal has constant 0 1 Hertz freq...

Page 26: ...d 1200 C 0 4 C K 160 C to 1372 C 0 4 C T 190 C to 400 C 0 4 C E 220 C to 1000 C 0 4 C N 100 C to 1300 C 0 4 C R 40 C to 1768 C 0 5 C S 100 C to 1768 C 0 5 C B 640 C to 1820 C 0 5 C C 0C to 2320 C 0 4...

Page 27: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 28: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Reviews: