19 |
P a g e
5.2.2
Thermocouple Input Data Type/Format
The SP-016 supports extended configuration and provides factory calibration. All data values are returned as 32-bit
floating point values.
Thermocouple Input Data Type/Format
7
6
5
4
3
2
1
0
Smart
Sensor
Sensor
Writable
Factory
Calibrate Reserved
Data Type
0
0
?
0
0x06 == FLOAT
5.2.2.1
Data Type
The 4-bit Data Type field determines the type of data of the specific sensor.
5.2.2.2
Factory Calibrate
Factory calibration is used on the SP-016 process inputs. Clearing this bit will disable the factory calibration values.
5.2.2.3
Sensor Writeable
The writable bit is cleared, indicating that the sensor values may not be overwritten.
5.2.2.4
Smart Sensor
Refer to the Smart Sensor Device Interface documentation.
5.2.3
Thermocouple Input Configuration
Thermocouple Input Configuration
7
6
5
4
3
2
1
0
Available Assigned
Apply
Scaling
Lock
Sensor Type (Range)
0
*
?
?
See Below
5.2.3.1
Sensor Type / Range
Sensor Type
Sensor Input Type (Range)
Measurement Type
0x00
Type J
0x20
Temperature (oC)
0x01
Type K
0x20
Temperature (oC)
0x02
Type T
0x20
Temperature (oC)
0x03
Type E
0x20
Temperature (oC)
0x04
Type N
0x20
Temperature (oC)
0x05
Reserved
0x06
Type R
0x20
Temperature (oC)
0x07
Type S
0x20
Temperature (oC)
0x08
Type B
0x20
Temperature (oC)
0x09
Type C
0x20
Temperature (oC)