10 |
P a g e
4.4
Setting Alarms
Alarms are set by clicking the
icon in SYNC on the desired input signal found in the
Inputs Configuration Tab
. Setup
the threshold and alarm type in the
Condition
section and then select which output to turn on in the
Action
section. The
alarm can be set to be latching or non-latching in the
Recovery
section.
4.5
ON/OFF Control
To configure ON/OFF Control on a device, navigate to the
Output Configuration Tab
in SYNC and click on the
icon
located to the right of the available outputs. Clicking the icon will open
Define ON/OFF Control
dialog box as seen below.
Choose the input with the active alarm that you would like to control and set your preferred parameters.