background image

• 

Non-intrinsically safe wiring cannot be run in conduit or open

   raceways together with intrinsically safe wiring.**

 Refer to Fig 6 for detailed connection to terminal studs.  All

   hardware, including terminal lugs, is supplied with unit.

 Fusing of the solid-state relays to be in accordance with

   Fig. 1.  Fuse F1 to be 6 amps slo-blo, 120 VAC for 120V
   line voltage; 250 VAC for 240 V application.

**Note:  All intrinsically safe wiring to intrinsically safe solid-state
   relays must be segregated from non-intrinsically safe wiring.

Nylon

Stud Nuts

Stud Cover

Terminals

Stud

Cover

Nylon

Stud Nuts

Terminals

Fig. 7.  Mounting of protective cover over
            sensor-connected terminals of unit.

Latching

Solid-State Relay

Non-Latching

Solid-State Relay

Notes:

1.  *(Lockwasher to be internal or external tooth type)
2.  Grounding hardwre to be #8 or larger and S.S.

Fig. 5.  Mounting Plate Grounding Detail

Fig. 6

Recommended method of connection to electrical
terminals.  All terminal hardware, including lug,
supplied with unit.

Mounting

Tab

3-1/8"

(79mm)

7/32" Dia.
(5.5 mm)

2-5/8"

(66.6 mm)

2-1/4"

(55mm)

3"

(76  mm)

1-5/8"

(41.3mm)

13/16"

(20.7mm)

Fig. 8.

Dimensions

P/N 158350

Mounting

 Plate

Screw

Lockwasher*

Lockwasher*

Nut

Lockwasher*

Nut

Terminal Lug

HEX Nut

Anti-Vibrational

Lockwasher

Terminal Lug

(Closed Ring Type)

Terminal Stud

(Tighten assembly to
between 3 and 5 in-lbs.)

Line & Load

Voltage

Range

Load

Current

Max

Turn-On

Sensitivity

(Typical)

Turn-Off

Sensitivity

(Typical)

Voltage

Loss

Operating

Temperature

Range

Switching
Operation

Weight

SBG22445
SBG25872

SBG25873

95 to

135 VAC

SBG41705

5A

Latching SSR

for Intrinsic

Safety

0.3 A

Steady

State

200 to

250 VAC

105 to

125 VAC

1 meg.

 

2 VAC

2 VAC

0

° 

to +120

°

F

+32

° 

to +120

°

F

6mA @

120 VAC

12 mA @

250 VAC

3 mA @

120 VAC

SPST N.O.
SPST N.C.

SPST N.O.

SPST N.O.

425g

425g

All AC voltage and current specifications are RMS values unless otherwise stated.  Housing material is Polysulfone.

Table 1.  Specifications

SSR for
Intrinsic

Safety

Output

Leakage

Current Max.

Model

Number

Description

<

 25 K

1 meg.

 

400 K

Reviews: