background image

WARRANTY

OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the
normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers
receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for
evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately
upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or
replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with
or shows evidence of being damaged as a result of excessive corrosion; or current, heat moisture or vibration;
improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components
which wear or which are damaged by misuse are not warranted. This includes contact points, fuses, and triacs.

OMEGA is glad to offer suggestions on the of use of its various products. Nevertheless, OMEGA only warrants
that the parts manufactured by it will be as specified and free of defects

OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY
DISCLAIMED.

LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of
OMEGA with respect to this order, whether based on  contract warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In
no event shall OMEGA be liable for consequential, incidental or special damages.

Every precaution for accuracy has been taken in the preparation of this manual; however, OMEGA ENGINEERING,
INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages
that result from the use of the products in accordance with the information contained in the manual.

SPECIAL CONDITION: Should this equipment be used in or with any nuclear installation or activity, purchaser will
indemnity OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
equipment in such a manner.

Summary of Contents for RH62C-MV

Page 1: ...OMEGA RH62C MV Humidity Temperature Transducer ...

Page 2: ... info omega com e mail info omega com Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 20 6418405 FAX 31 20 6434643 Toll Free in Benelux 06 0993344 e mail nl omega com Czech Republic ul Rude armady 1868 733 01 Karvina Hranice Czech Repubic Tel 420 69 6311627 FAX 420 69 6311114 e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 130 621 400 FAX 33 130...

Page 3: ... hygrom eter sensor SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the humidity temperature transducer CAUTION Do not immerse the transducer sensor head into liquids since this causes permanent damage to the sensor The meter when not in use please use protective metal cap cover the sensor head and rotate clockwise it to extend sensors life The...

Page 4: ...tive humidity Temperature Coefficient 0 1 times the applicable accuracy specification per C from C to 18 C and 28 C to 50 C Operating environment 0 C to 50 C at 75 relative humidity Storage environment 20 C to 60 C at 80 relative humidity Battery 4 pcs 1 5V AAA size Battery Life 200 hours typical Dimensions 170mm H x 44mm W x 40mm D Weight 200g including probe and batteries ...

Page 5: ... C to 0 C 50 C to 100 C RELATIVE HUMIDITY Humidity Sensor Electronic capacitance polymer film sensor The sensor is unaffected by water condensate is immune to most reagent vapors Measurement Range 0 to 100 RH Relative Humidity Output 10mV RH Accuracy 2 5 RH 10 to 90 RH 5 RH 10 90 RH Sensor Response Time for 90 of Total Range 60sec typical Sensor Stability 2 RH 2 years typical ...

Page 6: ...into the Vdc input jack and common or ground input jack on the DMM Observe polarity 2 Set the DMM to the 200mV range 3 Rotate counter clockwise to remove the protective metal cap 4 Set the power switch to the desired RH or C range 5 If the DMM display is over range Set the DMM to the 2V range 6 Read the DMM display 10mV C 10mV RH 7 Cover sensor head to extend sensor life when not in use ...

Page 7: ...raft e g fans radiating hand and or body heat etc Humidity measurement errors Due to steam water splashes dripping water or condensation not water condensate on the sensor etc However repeatability and long term stability are not impaired by this Contamination By dust in the air or measurements in powdery substances This can be largely avoided by using a corresponding filter The filter must be cle...

Page 8: ...e LOW BATT red LED lighted when replacement is needed To replace the batteries remove the screw from the back of the meter and lift off the battery cover Remove the batteries from battery contacts Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents ...

Page 9: ... use of its various products Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABI...

Page 10: ...pondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEFORE contacting OMEGA 1 P O number under which the product was PURCHASED 2 Model and serial number of the product under warranty and 3 Repair instructions and or specific problems relative to the prod...

Page 11: ...ctors Panels Assemblies þ Wire Thermocouple RTD Thermistor þ Calibrators Ice Point References þ Recorders Controllers Process Monitors þ Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTROL þ Metering Control Instrumentation þ Refractometers þ Pumps Tubing þ Air Soil Water Monitors þ Industrial Water Wastewater Treatment þ pH Conductivity Dissolved Oxygen Instruments pH CONDUCTIVITY þ pH Elect...