Installation and Maintenance

Preparation before installation

Prepare tools

Read the requirements 

for electric connection

select installation 

location

Select indoor unit 

installation location

Install wall-mounting 

frame, drill wall holes

Connect pipes of indoor 

unit and drainage pipe

Connect wires of indoor unit

Connect wires of outdoor unit

Bind up pipes and 

hang the indoor unit

Make the bound pipes pass 

through the wall hole and then

 connect outdoor unit

Neaten the pipes

Vacuum pumping and leakage detection

Check after installation and test operation

Finish installation

Note: this flow is only for reference; please find the more detailed installation steps in this section.

Select outdoor unit 

installation location

Install the support of outdoor unit

(select it according to the actual situation)

Install drainage joint of outdoor unit 

(only for cooling and heating unit)

Connect pipes of outdoor unit

 Start installation

Fix outdoor unit

Installation procedures

Summary of Contents for OTEC IEWQ Series

Page 1: ...IEWQ ICHQ Series High Wall Inverter Installation Manual...

Page 2: ...intenance 2 3 Installation 5 3 1 Installation Dimension Diagram 5 3 2 Installation Parts checking 7 3 3 Selection of Installation Location 7 3 4 Requirement For Electric Connection 7 3 5 Installation...

Page 3: ...1 Technical Information 1 Summary Part Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller...

Page 4: ...hout plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connect...

Page 5: ...d 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or fro...

Page 6: ...4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wr...

Page 7: ...m At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall Space to the obstructi...

Page 8: ...Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Not...

Page 9: ...le Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 1 Choosing Inst...

Page 10: ...ameter of 70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note I...

Page 11: ...lation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound...

Page 12: ...s show in Fig 20 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the handle and valve cover of outdoor unit and then remove the handle and valve cover As show in Fig 21 2 Remove the screw cap...

Page 13: ...ldnt be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose Can t be curved raised and fluctuant etc As show in Fig 26 Note The d...

Page 14: ...OMEGA IEWQ HQ High Wall Inverter Installation Manual IEWQ CHQ I3A IM1R0622 info otecomega com www otecomega com info otecomega com www otecomega com...

Reviews: