Installation and Maintenance

1. Select the installation location according to the require-

ment of this manual.(See the requirements in installation 

part)

2. Handle unit transportation with care; the unit should not

be carried by only one person if it is more than 20kg.

3. When installing the indoor unit and outdoor unit, a suffi

-

cient fixing bolt must be installed; make sure the installation 

support is firm.

4. Ware safety belt if the height of working is above 2m.

5. Use equipped components or appointed components dur-

ing installation.

6. Make sure no foreign objects are left in the unit after fin

-

ishing installation.

1. Avoid contact between refrigerant and fire as it generates

poisonous gas; Prohibit prolong the connection pipe by 

welding.

2. Apply specified refrigerant only. Never have it mixed with

any other refrigerant. Never have air remain in the refrigerant 

line as it may lead to rupture or other hazards.

3. Make sure no refrigerant gas is leaking out when

installation is completed.

4. If there is refrigerant leakage, please take sufficient

measure to minimize the density of refrigerant.

5. Never touch the refrigerant piping or compressor without

wearing glove to avoid scald or frostbite.

Refrigerant Safety Precautions:

Improper installation may lead to fire hazard, explosion, 

electric shock or injury.

Installation Safety Precautions:

connection pipe is not yet connected, air will be sucked in 

and cause pressure rise or compressor rupture, resulting in 

injury.

●Prohibit installing the unit at the place where there may be

leaked corrosive gas or flammable gas.

If there leaked gas around the unit, it may cause explosion 

and other accidents.

●Do not use extension cords for electrical connections. If

the electric wire

is not long enough, please contact a local service center 

authorized and ask for a proper electric wire.

Poor connections may lead to electric shock or fire.

●Use the specified types of wires for electrical connections

between the indoor and outdoor units. Firmly clamp the 

wires so that their terminals receive no external stresses.

Electric wires with insufficient capacity, wrong wire  

connections and insecure wire terminals may cause electric 

shock or fire.

Summary of Contents for OTEC IEWQ Series

Page 1: ...IEWQ ICHQ Series High Wall Inverter Installation Manual...

Page 2: ...intenance 2 3 Installation 5 3 1 Installation Dimension Diagram 5 3 2 Installation Parts checking 7 3 3 Selection of Installation Location 7 3 4 Requirement For Electric Connection 7 3 5 Installation...

Page 3: ...1 Technical Information 1 Summary Part Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller...

Page 4: ...hout plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connect...

Page 5: ...d 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or fro...

Page 6: ...4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wr...

Page 7: ...m At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall Space to the obstructi...

Page 8: ...Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Not...

Page 9: ...le Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 1 Choosing Inst...

Page 10: ...ameter of 70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note I...

Page 11: ...lation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound...

Page 12: ...s show in Fig 20 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the handle and valve cover of outdoor unit and then remove the handle and valve cover As show in Fig 21 2 Remove the screw cap...

Page 13: ...ldnt be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose Can t be curved raised and fluctuant etc As show in Fig 26 Note The d...

Page 14: ...OMEGA IEWQ HQ High Wall Inverter Installation Manual IEWQ CHQ I3A IM1R0622 info otecomega com www otecomega com info otecomega com www otecomega com...

Reviews: