In no circumstances can the grounding cable for main power
switch be disconnected.
Do not use a damaged power cable and replace it if it is
damaged.
When the air conditioner is used for the first time or when it is
powered off for a long time, it needs to be warmed up for at
least 12 hours before use.
CAUTION
Doing so puts you at risk of an electric shock.
These fins are sharp and you could cut you.
Condensation may form if the humidity is above 80 percent, if
the drain outlet is blocked or if the filter is polluted.
If the stand is damaged, the unit may fall and cause an injury.
Incomplete drainage may cause water leaks.
Do not remove the front panel. Some internal parts may cause
injury or be damaged.
Never expose children, plants or animals directly to the air
flow.
Falling or tumbling may result in injury.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
It may cause incomplete combustion or deformation of the unit
due to the heat.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
Wiring work must be done by authorized qualified
electricians.
All wiring works must comply with electrical safety
specifications.
It must be ensured that the air conditioner is well grounded,
that is, the main switch of the air conditioner must have a
reliable grounding cable.
It must be ensured that the minimum clearance between the
A separate power supply that meets the rated parameter
values must be provided for the air conditioner.
2. OPERATING INSTRUCTIONS
NOTE
The figures show in this manual are for reference only, and the
actual product may be different.
To ensure that the product continues to perform well, please operate
the air conditioner under the following temperature conditions.
Cooling
Heating
Dehumidific
ation
Room temperature
Outdoor temperature
Room temperature
Outdoor temperature
Room temperature
Outdoor temperature
10 to 55
Under 30
-15 to 24
10 to 55
Above 17
Above 12
1-phase
25
72
90 indoor unit
105 indoor unit
105 outdoor unit
2
27
2
19.5
6
6
32
220-240V~50Hz
1-phase 220-240V~50Hz
1-phase 220-240V~50Hz
1-phase 220-240V~50Hz
Model
Maximum
operating
current
Power Supply
Voltage and
frequency
Recommended
circuit breaker
(A)
Phase
1-phase
16
53
14.5
220-240V~50Hz
90 outdoor unit
22
25
1-phase 220-240V~50Hz
1-phase
32
120 outdoor unit
140 indoor unit
160 indoor unit
160 outdoor unit
2
33
2
27
6
6
40
220-240V~50Hz
1-phase 220-240V~50Hz
1-phase 220-240V~50Hz
1-phase 220-240V~50Hz
1-phase
6
120 indoor unit
2
220-240V~50Hz
140 outdoor unit
32
40
1-phase 220-240V~50Hz