6

If  the  problem  remains,  please  contact  the  distributor  or  Clivet's  air 
conditioner  customer  service  center,  and  provide  info  about  the 
product model and the fault details.

Do not replace the power cable by yourself to avoid danger. 
Do not repair the air conditioner by yourself.

CAUTION

Fault

Cause

Solution

Starting 
failure

Power failure

Power switch is off
The fuse of the power switch is blown.

The batteries of the remote

controller are exhausted.

The time set for the timed 

power-on has not arrived.

Wait for the power supply
to be restored.
Turn on the power
Replace the burnt fuse.
Replace the batteries.

Wait or cancel the 
setting.

The temperature setting is 
inappropriate.

The air inlet or outlet of the 
IDU or ODU is blocked

Doors and windows are open.

Remove the obstacles.

Close the doors and windows.

The air inlet or outlet of the 
IDU or ODU is blocked.

Compressor 3-minute protection
The temperature setting 
is inappropriate.

Remove the obstacles and 
perform the operation again.

Wait.
Set the temperature 
properly.

There is air 
blowing, but 
the cooling 
effect is poor.

There is air 
blowing, but 
the unit 
cannot supply 
cold air.

Set the temperature properly. 
Increase or decrease the 
temperature. Read Operating 
Methods for details.

1

5

3

7

2

4

6

No. Symptoms

Check item

Cause

The fan speed 

cannot be 

adjusted.

No remote 

controller signal 

is sent when      

is pressed.

Check whether the 

mode on the display 

is Auto.

When Auto is selected, the 

IDU will automatically select 

Auto as the fan speed.

When Dry is selected, the IDU 

will automatically select Auto 

as the fan speed.

The fan speed can only be 

selected in the Cool, Heat, 

and Fan modes.
The remote controller cannot 

send signals when the 

batteries are exhausted.

Check whether the 

mode on the display is 

Dry.

The batteries of the 

remote controller 

are exhausted.

The 

temperature 

indicator is off.

In the Fan mode, the 

temperature cannot be set.

Check whether the 

mode on the display 

is Fan.

Timed Off 

disappears 

after a while.

After the set time has arrived, 

the air conditioner stops.

Check whether the 

time set on the timer 

has been reached.

Timed On 

disappears after 

a while.

When the time to start the 

operation of the air conditioner 

has arrived, the air conditioner 

will automatically start running 

and the corresponding display 

will disappear.

Check whether the 

time set on the timer 

has been reached.

The air 

conditioner 
makes no 

receiving sound 
when        is 
pressed.

Point the signal transmitter of 

the remote controller towards 
the receiver of the IDU and 

press         .  The controller 
signal cannot be received 

since the air conditioner is 
off.

Check when       is 

pressed, whether the 
signal transmitter of 

the remote controller 
is pointed to the 

receiver of the IDU. 
Check whether the 
air conditioner’s 

power switch is on.

The remote 

controller does 

not respond to 

button pressing.

Button is locked.

Check the display of 

the remote 
controller

Summary of Contents for OTEC ICHD018

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ... IDU ODU Wired controller is standard The air conditioner is delivered from the factory without connecting pipes All the figures in the manual explain only the general appearance and dimensions of the unit The air conditioner you purchased may not be completely consistent with the appearance and functions listed in the figures Please refer to the actual product CAUTION The air conditioner consists...

Page 8: ...a leak the oxygen in the room may be affected causing a serious accident If it does and comes into contact with fire a harmful gas will result Do not use the unit until a technician instructs you that it s safe to do so Do not use it for cooling precision instruments food plants animals or art or you may damage the unit Otherwise an electric shock and injury may result To avoid electric shocks ens...

Page 9: ...omply with electrical safety specifications It must be ensured that the air conditioner is well grounded that is the main switch of the air conditioner must have a reliable grounding cable It must be ensured that the minimum clearance between the A separate power supply that meets the rated parameter values must be provided for the air conditioner 2 OPERATING INSTRUCTIONS NOTE The figures show in ...

Page 10: ...he rated voltage The power cable must be equipped with a protective device such as a leakage protector or an air switch and its capacity must be greater than 1 5 times the maximum current of the air conditioner Use the dedicated line and the effective grounding socket that matches the standard plug of the air conditioner The plug of this unit provides a grounding plug which must not be changed Use...

Page 11: ...egree of frosting It generally takes 2 to 10 minutes During the defrosting process the ODU may emit steam due to the rapid defrosting which is a normal phenomenon In an environment where the indoor relative humidity is too high when the IDU runs in the cooling mode white mist may appear due to the humidity and the temperature difference between the air inlet and outlet When the air conditioner is ...

Page 12: ... L9 L0 and L1 90 105 120 140 160 Error code E0 E1 E3 E5 E50 E51 E52 E53 E54 E55 E6 E60 E61 E7 E71 E72 E73 E74 EE PA PF P0 P1 P10 P11 P12 P2 P4 P40 P41 P42 P43 P44 P45 P46 P47 P48 P49 P6 P8 P81 P82 P9 P90 P91 L0 L1 L2 L3 L5 L6 Error or protection definition IDU EEPROM error Indoor outdoor communication fault Indoor fan stall fault ODU temperature sensor or EPROM fault ODU temperature sensor fault O...

Page 13: ...gnal is sent when is pressed Check whether the mode on the display is Auto When Auto is selected the IDU will automatically select Auto as the fan speed When Dry is selected the IDU will automatically select Auto as the fan speed The fan speed can only be selected in the Cool Heat and Fan modes The remote controller cannot send signals when the batteries are exhausted Check whether the mode on the...

Page 14: ...ide Max input current Max power input Permitted pressure of cooling system Refrigerant Cooling capacity Rated current Rated power W A W M3 h dB A kg mm dB A kg mm A W MPa mm mm 220 240V 50Hz 4 4 26 6 14000 6000 78 5 51 42 40 1720 32 6830 R410A 3200g 59 30 8 4 4 27 5 91 60 33 7120 R410A 3800g 6200 15500 51 42 40 30 8 1720 220 240V 50Hz 220 240V 50Hz Circulating air flow Noise Net weight External di...

Page 15: ...ter unit For safety reasons always turn off the air conditioner and turn off the power before cleaning the air conditioner For air conditioners with auxiliary heaters the auxiliary heater is secured between the wind turbine and the heat exchanger of the IDUs using screws and the minimum gap with the flammable surface is 12 mm The user is prohibited from disassembling and repairing the part Otherwi...

Page 16: ......

Reviews: