background image

 

 

WARRANTY/DISCLAIMER

 

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months 

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

one (1) year product warranty 

to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product.

 

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including  but  not  limited  to  mishandling,  improper  interfacing,  operation  outside  of  design  limits, 

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of 

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not 

limited to contact points, fuses, and triacs.

 

OMEGA  is pleased to offer  suggestions on the  use of its various  products.  However, 

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any 

damages that result from the use of its products in accordance with information provided by 

OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR 

REPRESENTATIONS  OF  ANY  KIND  WHATSOEVER,  EXPRESSED  OR  IMPLIED,    EXCEPT    THAT    OF  

TITLE,  AND  ALL  IMPLIED  WARRANTIES  INCLUDING  ANY    WARRANTY    OF    MERCHANTABILITY  

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF

 

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of 

OMEGA with respect to this order, whether based on contract, warranty, negligence, 

indemnification, strict liability or otherwise, shall not exceed the purchase price of the 

component  upon  which  liability  is  based.  In  no  event  shall  OMEGA  be  liable  for 

consequential, incidental or special damages.

 

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications  or  used  on  humans.  Should  any  Product(s)  be  used  in  or  with  any  nuclear  installation  or 

activity, medical application, used on  humans, or misused in  any  way, OMEGA assumes no  responsibility 

as  set  forth  in  our  basic  WARRANTY/DISCLAIMER  language,  and,  additionally,  purchaser  will  indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

 

RETURN REQUESTS/INQUIRIES

 

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE 

RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN 

(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID

 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.

 

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit.

 

FOR 

WARRANTY 

RETURNS, please have the 

following information available BEFORE 

contacting OMEGA:

 

1.  Purchase Order number under which the product 

was PURCHASED,

 

2.  Model and serial number of the product under 

warranty, and

 

3.  Repair instructions and/or specific problems 

relative to the product.

 

FOR 

NON-WARRANTY 

REPAIRS, consult OMEGA

 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA:

 

1. 

Purchase Order number to cover the COST 

of the repair,

 

2. 

Model and serial number of the product, and

 

3. 

Repair instructions and/or specific problems 

relative to the product.

 

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.

 

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

 

©  Copyright  2011  OMEGA  ENGINEERING,  INC.  All  rights  reserved.  This  document  may  not  be  copied,  photocopied, 

reproduced,  translated,  or  reduced  to  any  electronic  medium  or  machine-readable  form,  in  whole  or  in  part,  without  the  

prior written consent of OMEGA ENGINEERING, INC.

 

Summary of Contents for OSHFV Series

Page 1: ... info omega com For latest product manuals omegamanual info OSHFV Series OS HFV50 Model High Field of View High Temp Fixed IR Sensor with 6 digit LCD and analog digital outputs CAUTION This product is not intended for medical use or use on humans ...

Page 2: ...L 420 59 6311899 FAX 420 59 6311114 e mail info omegashop cz France Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de United Kingdom OMEGA Engineering Ltd ISO 9001 Certified ...

Page 3: ...a non contact way OS HFV50 Model Sensor Mounting nut x 1 Fixed mounting bracket x 1 3m connection cable standard 4 cores User manual Keep the lens clean at all times Any foreign matter on the lens would affect measurement accuracy Blow off loose particles using clean compressed air The lens surface can be cleaned with a soft humid tissue moistened with water or a water based glass cleaner Never us...

Page 4: ...ich is greater 0 5 of reading 2 C Emissivity 0 100 1 000 At 23 5 C emissivity LR 0 95 H1 1 00 Electrical Specifications Signal Output 4 20mA Digital Communication TTL USB with optional communication cables Max Loop Resistance 500Ω Power Supply 24 VDC 20 100 mA Display 6 digit backlight LCD General Specifications Environmental Rating IP 64 Ambient Temperature 0 C 70 C Storage Temperature 20 C 85 C ...

Page 5: ...ndicate the target spot diameter at any given distance between the target object and the sensing head The spot size will change in longer distance corresponding to the following drawing In order to prevent measuring errors the object must be as least as big as the spot size ...

Page 6: ...ng Position the sensor so the two laser beams are marking the exact location and size of the target Please gently move it around until the temperature signal reads the highest Hold the sensor in place and secure the mounting base At ambient temperature 50 C the laser will be switched off automatically LASER LIGHT DO NOT STARE INTOBEAM CLASS 2 LASER 1mW 650 nm IEC 825 1994 red 24VDC power black 24V...

Page 7: ...l appears at the right side of the selected function confirming into Setting Mode 3 Press the down or up key to select the functional parameter 4 No action for 7s forces the unit to leave the Setting Mode and save the parameter 5 Laser ON OFF Pressing the down key to switch laser sighting on or off Fixed Mounting Bracket OS HFV50 FMB Adjustable Mounting Bracket OS HFV50 AMB ...

Page 8: ...will be displayed in the left bottom active COM port and successfully communication with the connected sensor The target temperature will show onthe left in digital form Starting the measurement Please press the measuring key Menu Measurement M Start Scaling of the temperature axis In the menu item settings Global Auto Scaling the temperature range of the diagram is automatically adapted to the re...

Page 9: ... otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on human...

Page 10: ...dicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pHElectrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity Equipment DATA ACQUISITION Data Acquisition Engineering Software Communications Based Acquisition Systems Plug in Cards for Apple IBM Compatibles Data Logging Systems Recorders Printers Plot...

Reviews: