![background image](http://html1.mh-extra.com/html/omega/oshfv-series/oshfv-series_user-manual_3957763004.webp)
5. Technical Data
Measurement Specifications
Model
LR
H1
Temperature Range
0°C
~
1300°C
600°C
~
1600°C
Spectral Response
8
~
14μm
1 μm
Field of View
120:1
300:1
Response Time (95%)
150 ms
5 ms
Accuracy
*1
±1% of reading or ±1.5°C,
which is greater
±(0.5% of 2°C)
Repeatability
*1
±0.5% of reading or ±1°C,
which is greater
±(0.5% of 2°C)
Emissivity
0.100
~
1.000
*¹ At 23±5°C
,
emissivity LR=0.95, H1=1.00
Electrical Specifications
Signal Output
4 ~20mA
Digital Communication
TTL / USB (with optional communication cables)
Max. Loop Resistance
500Ω
Power Supply
24 VDC ±20%, < 100 mA
Display
6-digit backlight LCD
General Specifications
Environmental Rating
IP 64
Ambient Temperature
0°C~70°C
Storage Temperature
-20°C ~ 85°C
Relative Humidity
10% ~ 95%
Cable Temperature
-20°C~ 80°C
Cable Length
3 m
Weight
500g (without cable)