background image

 

 

 

12 

 

 

Maintenance and Cleaning 

BULB REPLACEMENT 

 

WARNING: The bulb must be replaced by the manufacturer, its service agent or similarly qualified 
persons

 

Remove the grease filter. 

 

Use a screwdriver to remove the 4pcs screws on the large glass and carefully remove the glass. 

 

Then slightly pull the light connecting wire out and dismantle the terminal of the light connecting 
wire. Replace the lamp. 

 

Apply the reverse procedure to install the light back. 
 

ILCOS D code for this lamp is: DSR-1.5/65-S-64 

 LED modules

 round lamp  

 Max wattage: 2×1.5 W  

 Voltage: DC 12V 

 

Dimensions: 

 

 

NOTE. 

 

Always switch off the electricity supply before carrying out any operations on the appliance. When 
handling bulb, make sure it has completely cooled down before any direct contact with hands. 

 

When handling bulbs hold with a cloth or gloves to ensure perspiration does not come in contact 
with the bulb as this can reduce the life of the bulb. 

 

Before changing the lights, make sure that the appliance is turned off and unplugged. 

 

Protect against danger when changing lights, such as wearing gloves. 

 
 
 

 

 

 

Summary of Contents for ORCG60MB

Page 1: ...Instruction Manual OMEGA CURVED GLASS RANGEHOOD ORCG60MB ORCG90MB...

Page 2: ...iance such as warranty registration manuals features and specifications please visit omegaappliances com au if you are in Australia and omegaappliances co nz if you are in New Zealand or contact our C...

Page 3: ...rves the right to alter specifications and appearances without notice Contents Important Safety Warnings 4 Appliance Details 5 Installation Instructions 6 Operating Instructions 10 Maintenance and Cle...

Page 4: ...ervice centre or similarly qualified persons to avoid a hazard 11 For indoor use only 12 It is recommended to operate the range hood prior to cooking 13 It is recommended to leave the range hood in op...

Page 5: ...ils Rangehoods ORCG60MB ORCG90MB Rated Voltage 220 to 240V 50Hz Motor Input Power 190W Lamp LED 2 x 1 5W Rated Input Power 193W Max Airflow 750m3 Hr Outlet Diameter 150 mm Power Connection 10 A Plug O...

Page 6: ...V flap because the outlet may vary according to different models and configurations To mount the V flap 1 you should 1 Mount two half parts 2 into the body 6 2 The pin 3 should be top oriented 3 The a...

Page 7: ...r hanging the hood and inside chimney bracket Drill 4 pcs 8 holes they are for fixing inside chimney bracket and the hood and keep the hood level The fixed position of the outside chimney bracket is t...

Page 8: ...crews here should be sure the inside chimney can be moved inside freely See pic 6 8 After adjusting the height fix the body with 2 pcs of ST4 30mm safety screws Note The two safety vents are positione...

Page 9: ...ny existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe should not be less than 120 you must d...

Page 10: ...or light of lamp button and power button will lit on Press lamp button again to turn off the lights Indicator light of lamp button and power button will be off And recycle like this 4 Press the High b...

Page 11: ...be cleaned with warm soapy water or a cloth The stainless steel must be cleaned regularly e g Weekly to ensure a long life expectancy Dry with a clean soft cloth A specialized stainless steel cleaning...

Page 12: ...l the light back ILCOS D code for this lamp is DSR 1 5 65 S 64 LED modules round lamp Max wattage 2 1 5 W Voltage DC 12V Dimensions NOTE Always switch off the electricity supply before carrying out an...

Page 13: ...t Switch power outlet on Oil leakage One way valve and the air ventilation entrance are not tightly sealed Take down the one way valve and seal with sealant Leakage from the connection of U shaped sec...

Page 14: ...14...

Page 15: ...1...