background image

 

6

needed on any treaded hole in the bracket 

with the bolts provided.  

 

Water connections 

-Use the same flex pipes you had on your 
old tank water heater or replace them with 

new ones if the old ones are rusted or 

damaged. On the hot side (left side of the 
unit!) as closest possible to the unit install 

a Pressure relief valve. 
 NOTE: 

Temperature relief valve is not 

necessary or required because the 

unit has a integrated, redundant over 

temperature protection system.

  

-The pipe in the discharge part of the valve 
has to be of a minimum ½ inch galvanized 

or cooper pipe 

-The discharge valve has to vent to the 
exterior of the building  

-The discharge line is not be allowed to 
have treads on the end. 

-The discharge line can not be run in an 

upward direction 
-The discharge line must terminate 

between 6” and 24 inch above ground 
level. 

 

Gas Installation 

 
The gas line is from the bottom of the unit: 

Connect the gas unit thru hard line or a 
approved flex hose not less then ½ 

“diameter. You can use your old flex hose 

if is sufficient long and at of list ½” 
diameter.  

 

Warning:    

 
Your line has to have a pressure of 

minimum 0.33 PSI and the capacity 

to move a sufficient quantity of gas to 
produce 95.000 Btu.  

Lengthy gas pipe with out step-
downs will not be able to supply the 

necessary gas volume for the unit 

 

 

In order that the unit to work you need to 
install 2 Dcell batteries. (Not provided!) 

Warning:

  Follow the polarity of 

the batteries on installation. Incorrect 

batteries installation will render the 
unit inoperative. 

The freezing device is not adjustable, do not 

turn or disassemble. Only a authorized 
technician can perform maintenance on the 

anti-freezing device  

  

Maintenance   

 

The unit is virtual maintenance free with the 
exception of the de-scaling every 1 to 3 

years based of the PH of the local water 
supply. The harder is the water, more often 

the de-scaling has to be done. Ask a local 
professional for advice in regard to the 

composition of the water.  Your local Water 

Company or your local Gas Company can 
help you with the necessary data. 

De-scaling involve harsh chemicals and 
specialized tools and can only be done by a 

professional.  

 

 

 

Summary of Contents for OME 412

Page 1: ...mation and instructions in this manual is not followed exactly a fire or explosion is possible causing property damage personal injury or death Warning Any Gas appliance creates flue gasses carbon mon...

Page 2: ...92 000 Btu Gas Connection NPT Water Connection 3 4 NPT Water pipes location On the top of the unit Water Pressure Min 19 psi Max 150 psi Recommended 55 psi Natural Gas Pressure Inlet Min 0 33 psi Max...

Page 3: ...sal The Discount tickets They are also 2 mounting brackets taped on the back of the unit Safety Talk 1 Always follow all local codes or in absence of local codes follow the actual edition of National...

Page 4: ...r heater 7 Operation OME 412 is a instantaneous thankless water heater designed to efficiently supply domestic hot water We combine the principle which is been around from the beginning of the 1900 wi...

Page 5: ...adiant temperature on any place on the unit is under 100 F so the possibility of Fire by contact is eliminated Freeze Prevention We see no reason to install your water heater outside OME 412 is been d...

Page 6: ...meter You can use your old flex hose if is sufficient long and at of list diameter Warning Your line has to have a pressure of minimum 0 33 PSI and the capacity to move a sufficient quantity of gas to...

Page 7: ...the water If the water is too cold your water volume is too big Need to reduce the overall water flow thru the unit to 12 liters per minute or until the temperature of the resulting water is acceptab...

Page 8: ...0 86 91 96 101 106 111 4 75 84 89 94 99 104 109 The result for Output temperature was reduced to 130 Degrees by the temperature safety devices anti scalding device included in the design of the unit T...