5
Temperature
The output temperature of the
OME 412 is been preset by the factory
NOT TO EXCEED 120 F
This is controlled by the computer and
Temperature limiters sensors and can
not be adjusted higher by any
technician.
WARNING
Temperature over 120 F (50 C) can
cause severe burns or even death. The
Disabled, elderly and children’s are at a
high risk of being injured by high
temperature of water.
Always feel the temperature of the water
before you enter in to the shower.
Do not leave disabled, elderly and
children’s unsupervised.
SAFETY SISTEMS
OME 412 is equipped with the following
safety systems:
- Electronic Ignition-
Your unit will
never have a pilot light burning gas day
and night and wasting your gas and
presenting a fire danger
-
ION technologies –
This system
read the flame 20 times a minute, and
detects temperature of the flame. If the
temperature does not denote a fire, the
unit will attempt reigniting the flames.
After the second unsuccessfully attempt
the system will shut down your gas flow,
therefore eliminating discharging of
unburned gas and the danger of
explosion.
This unit passes the most stringent
emission tests in the industry.
-Space age insulation:
-The entire unit is “Cold to touch” The
radiant temperature on any place on the
unit is under 100 F so the possibility of
“Fire by contact” is eliminated.
- Freeze Prevention-
We
see no reason
to install your water heater outside. OME
412 is been design for inside installation so
therefore do not need expensive and
energy consuming resistors to keep the
unit from freezing.
- Over pressure valve-
to eliminate any
possibility of water overpressure due to a
malfunction.
-
Alloy coating
Heater Exchanger is not exposed cooper like
on most of the units on the market, but is
coated with a special alloy which is able to
sustain, with out damage, temperatures in
excess of 1500 F. ALL of those safeties are
incorporated in the unit with only one reason
in mind:
You, the customer!
INSTALATION
Location
This instantaneous water heater is a
complete, perfect replacement kit system to
replace your old tank unit with out any
plumbing modification.
The recommended distances from immediate
walls or other object is as follow:
-4 inch from the sides,
-8 inches from the top. (ceiling or roof)
-3 inches from the front.
-24 inches from the floor is required by the
fire codes but we recommend to have it
installed eyed site level for easy control,
supervision or maintenance.
- Use the 2 brackets provide for installation.
Find the studs and connect the 2 closest
studs together with the bracket. The water
heater
do not need to be in the center of
the bracket.
Hung the water heater as