74 API Command Reference
Personal488 User's Manual For Windows95 and Windows NT
Local
Syntax
INT WINAPI Local(DevHandleT devHandle);
devHandle
refers to either an IEEE 488 interface or an external device.
Returns
-1
if error
Mode
SC
Bus States
*REN
Examples
errorcode = Local(ieee);
To unassert the Remote Enable (
REN
) line, the
IEEE 488 interface is specified.
errorcode = Local(wave);
To send the Go To Local (
GTL
) command, an
external device is specified.
See Also
LocalList, Remote, AutoRemote
In the System Controller mode, the
Local
command issued to an interface device, causes Driver488 to
unassert the Remote Enable (
REN
) line. This causes devices on the bus to return to manual operation.
A
Local
command addressed to an external device, places the device in the local mode via the Go To
Local (
GTL
) bus command.