Product Overview

The OM-CP-ULTRASHOCK-A is a 3-axis shock / acceleration data logger with additional channels for 
temperature, humidity and barometric pressure. Each of the six channels may be made active or inactive as 
needed. Disabling channels will provide additional storage to the enabled channels.

The OM-CP-SHOCK300 is a 3-axis shock / acceleration data logger. Each of the three channels may be made 
active or inactive as needed. Disabling channels will provide additional storage to the enabled channels.

The OM-CP-ULTRASHOCK-A and OM-CP-SHOCK300 are specifically designed for documenting dynamic 
environments such as moving vehicles, trucks, containers, ships, etc. The device is also valuable in 
characterizing environments such as production and assembly lines of delicate electronics, IC fabrication, 
communications and computer components.

The OM-CP-ULTRASHOCK-A and OM-CP-SHOCK300 contain two separate accelerometers to provide high 
sensitivity and accuracy up to 15g or higher levels of shock monitoring up to 300g. One of three operating 
ranges must be chosen during setup for a logging session. Those ranges are +/- 15g (low g accelerometer), +/- 
100g and +/- 300g (high g accelerometer).

Physical Mounting

The most accurate transfer of shock, vibration and acceleration 
to the final logged data will occur when the mounting is 
mechanically rigid. Typically, this would occur when the OM-CP-
ULTRASHOCK-A and OM-CP-SHOCK300 are mounted by two 
bolts directly to a solid metal, flat surfaced object of significant 
mass. 

For various applications, the rigid “bolted down” mounting may not be optimal or practical. The bottom 
surface of the OM-CP-ULTRASHOCK-A and OM-CP-SHOCK300 are precision machined flat. It is possible to 
mount the unit by the use of a double-sided adhesive material. Omega does not make recommendations of 
specific materials but several points to consider are:
• Adhesive joint should be as thin as possible
• Adhesive joint must have adequate strength to support the unit under conditions expected in use 

(temperature, shock, vibration, etc.)

• Adhesive joint material should be as stiff as possible (high durometer)

Orientation of Axes

The illustration to the right shows the directions 
of the x, y and z axes. They are also laser engraved 
on the front face of the unit. If an OM-CP-
ULTRASHOCK-A and OM-CP-SHOCK300 are 
positioned so that any axis points upward, that 
axis will report a g force of +1 g.

OM-CP-ULTRASHOCK-A & OM-CP-SHOCK300 

X Axis

Y Axis

Z Axis

Mounting Holes

Summary of Contents for OM-CP-ULTRASHOCK-A

Page 1: ...nd Tri Axial Shock Data Logger OM CP SHOCK300 Tri Axial Shock Data Logger MQS5089 0120 Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com...

Page 2: ...ies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start stores the dataset as it records while connected to the logger The status of the devi...

Page 3: ...accelerometer 100g and 300g high g accelerometer Physical Mounting The most accurate transfer of shock vibration and acceleration to the final logged data will occur when the mounting is mechanically...

Page 4: ...out USB connected and adequate battery charge level Flashes every 15 seconds maximum Indicates low battery charge level Logging Data with USB communication Flashes every 15 seconds Indicates normal op...

Page 5: ...lay in response time to humidity and temperature measurements as the OM CP ULTRASHOCK A processes shock events before other parameters Pressure The OM CP ULTRASHOCK A pressure sensor is designed to me...

Page 6: ...nly sample data at the logging rate For instance if a 30 second logging rate was selected then only a single data point is captured at each 30 second instant The potential to lose valuable data can be...

Page 7: ...red at the selected logging rate The trigger sample count should be chosen carefully because it may gather data points for which we have no interest For instance if 100 were entered and the logging ra...

Page 8: ...only used for the duration of the triggered shock events plus a post event buffer which is user programmable Product Maintenance Battery Charging and Care The OM CP ULTRASHOCK A and OM CP SHOCK300 bat...

Page 9: ...midity sampled approx every 2 seconds at intervals shorter than 2 seconds Otherwise sampled at the reading rate GENERAL Memory 3 593 358 readings 598 893 per channel all channels in use Start Modes So...

Page 10: ...l Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate Password Protection An optional password may be programmed into the device to restrict access to...

Page 11: ...a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installati...

Reviews: