GAS  CONNECTION 

 

This  appliances  is  suitable  for  installation  with  Natural 
Gas or ULPG 

Refer  to  page  11  for  the  relevant  burner  pressure  and 

appropriate  injector  sizes.  When  the  appliance  is  to  be 
connected  to  Natural  Gas  then  the  pressure  regulator 
supplied  must  be  fitted  to  the  gas  inlet. A  test  point  (for 
checking  the  gas  pressure)  is  supplied  either  with  the 

regulator  or  as  a  separate  fitting  in the  case  of  ULPG 

appliances.

 

 

Connection  of  the  appliance  to  the  gas  supply  must  be 
in  accordance  with  the  requirements  of AS5601.  A  ½ ”

 

BSP connector  at the  inlet is recommended  and the  gas

 

supply line to the appliance must be of adequate length

 

to  allow  sufficient  withdrawal  of  appliance  for  service  or 
disconnection and be:

 

 

a) 

annealed copper pipe; or 

b) 

a  hose  assembly  complying  with  the  requirements  of AS1869  - Class 

B, 1Omm diameter, maximum length 1OOOmm. 

 

The appliance  must  be installed with  provision to  allow the  gas to  be turned  off 
and  disconnected  for  servicing  and  removal  of  the  appliance  as  required  from 
the gas supply. 

Before  the  appliance  is  operated  make  certain  all  relevant  parts  are  placed  in 

the correct position. 
When the installation is completed the installation connections of appliance will require 
to  be  leak tested,  the  burner  operating  pressure  and flame  checked  and  adjusted. 
Warranty  service  calls  do  not cover  these  adjustments! 
To  check  the  operating  pressure  of  the  appliance  it  is  recommended  at  last  2 
large size burners are used. Ensure appliance is secured to wall when installation 
is completed. 

N.G. The  regulator  supplied  must  be fitted  to the 

½” 

BSP thread  at the  rear  of 

the  appliance.  An  approved  manual  shut-off  valve  must  be  installed.  The  N.G. 
regulator must be checked and adjusted to 1.0kPa after installation. 

 

ULPG Can be connected to the inlet fitting directly. The 

 

pressure must be checked to ensure it is operating at 

2.75kPa. A separate test point fitting must be installed 

between the piping & the appliance for the pressure to    

 

be checked to ensure it is operating at 2.75kPa. 

 

Summary of Contents for OG60XA

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS GAS HOBS MODELS OG60XA OG61XA OG62XA OG63XA OG64XA OG67XA OG72XA OG90XA OG91XA OG92XA...

Page 2: ...It contains all the necessary instructions for maintaining the appearance and functional qualities of the hob INSTRUCTIONS FOR THE INSTALLER these are for the Authorised Person who must carry out a su...

Page 3: ...proper The Manufacturer declines all responsibility for improper use DO NOT leave the packing in the home environment Separate the various waste materials and take them to the nearest special garbage...

Page 4: ...MARINE CRAFT OR IN CARA VANS IT SHALL NOT BE USED AS A SPACE HEATER DO NOT spray aerosols in the vicinity of this appliance while it is in operation The Manufacturer declines all responsibility for da...

Page 5: ...ce is to be connected to NG then the pressure regulator supplied MUST be fitted to the gas inlet A pressure test point for checking the gas pressure is supplied either with the regulator or as a separ...

Page 6: ...ensure the supply to the appliance is operating at 2 75kPa Clearance Above and Around Domestic Cookers 200mm from the edge of the burner to combustible materials on vertical sides of the appliance 65...

Page 7: ...the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600mm or for an overhead exhaust fan 650mm Any other downward facing combustible surface less...

Page 8: ...riphery of the nearest burner to a horizontal combustible surface is less than 200mm then E shall be 10mm or more or the horizontal surface shall be above the trivet See insets above NOTES 1 Requireme...

Page 9: ...ow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are placed in t...

Page 10: ...iances cannot accept responsibility for any damage to persons or to property arising from faulty connection or non connection to earth Before connecting installing or servicing the hob the plug should...

Page 11: ...a 7mm tube spanner Replace in or der with new injectors make sure the correct size injectors are used See data on underside of hob for size or refer to page 10 for chart 6 The regulator is required to...

Page 12: ...l Gas Burner Injector size mm MJ h NG 1 00 kPa Small 90 3 6 Medium 1 15 6 3 Large 1 55 10 8 Wok 1 75 13 2 Fish 1 55 10 8 ULPG Burner Injector size mm MJ h NG 2 75 kPa Small 0 55 4 0 Medium 0 66 6 3 La...

Page 13: ...ensure all control knobs are in the OFF position and the appliance has cooled completely Before any maintenance can be carried out you MUST disconnect the appliance from the electricity supply CLEANIN...

Page 14: ......

Reviews: