background image

 

 
 
 
 
 

INTRODUCTION 

 

MARKINGS: include the following: 

(i) 

Gas Type Label: fixed to the underside of the appliance. 

 

(ii) 

Data  plate:  fixed  to  the  underside  of  the  appliance  stating  Model 

Number,  AGA  or  SAI-GLOBAL  Approval  Number,  Gas  operating  pressure, 
Nominal Gas Consumption etc. 

 

(iii) 

AGA  or  SAI-GLOBAL  label  fixed  to  the  underside:  showing  that  the 

appliance conforms to the Standards. 

 

INSTALLATION INSTRUCTIONS: 

 

Refer to the  Data Plate on the  underside of the appliance for  information  on gas 

consumption, injector sizes etc. 

Refer to Figure 5 for dimension information and cut out size for bench tops. 

 

This hotplate is suitable for installation with Natural Gas or ULPG. 

Refer  to  data  plate  on  appliance  for  relevant  burner  pressure  and  appropriate 

injector  sizes.  When  the  appliance  is to  be connected  to  NG, then the  pressure 
regulator  supplied  MUST  be  fitted  to  the  gas  inlet.  A  pressure  test  point  (for 
checking  the gas  pressure)  is supplied  either with the  regulator  or as a separate 
fitting for ULPG. 

 

Connection  of the appliance to the gas supply  MUST be in accordance with the 

requirements  of AS  5601. A ½”BSP  connector  at the  inlet is recommended  and 
the  gas  supply  line  to  the  appliance  must  be  of  adequate  length  to  allow 
sufficient withdrawal of the appliance for service or disconnection and be: 

a) 

annealed copper pipe, or; 

b) 

a  hose  assembly  complying  with  the  requirements  of  AS1869,  Class 

'B', 1Omm diameter, maximum length 1OOOmm. 

 

When  the  installation  is  completed,  the  hotplate  will  require  to  be  leak  tested 
and  the  burner  operating  pressure  and  flame  checked  and  adjusted 
accordingly.  The duplicate  data plate should be attached to an area adjacent  to 
the  appliance  eg.  In  a  cupboard  which  is  accessible  for  reading  the  appliance 
details. 

 
 
 
 

 
 

Summary of Contents for OG60XA

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS GAS HOBS MODELS OG60XA OG61XA OG62XA OG63XA OG64XA OG67XA OG72XA OG90XA OG91XA OG92XA...

Page 2: ...It contains all the necessary instructions for maintaining the appearance and functional qualities of the hob INSTRUCTIONS FOR THE INSTALLER these are for the Authorised Person who must carry out a su...

Page 3: ...proper The Manufacturer declines all responsibility for improper use DO NOT leave the packing in the home environment Separate the various waste materials and take them to the nearest special garbage...

Page 4: ...MARINE CRAFT OR IN CARA VANS IT SHALL NOT BE USED AS A SPACE HEATER DO NOT spray aerosols in the vicinity of this appliance while it is in operation The Manufacturer declines all responsibility for da...

Page 5: ...ce is to be connected to NG then the pressure regulator supplied MUST be fitted to the gas inlet A pressure test point for checking the gas pressure is supplied either with the regulator or as a separ...

Page 6: ...ensure the supply to the appliance is operating at 2 75kPa Clearance Above and Around Domestic Cookers 200mm from the edge of the burner to combustible materials on vertical sides of the appliance 65...

Page 7: ...the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600mm or for an overhead exhaust fan 650mm Any other downward facing combustible surface less...

Page 8: ...riphery of the nearest burner to a horizontal combustible surface is less than 200mm then E shall be 10mm or more or the horizontal surface shall be above the trivet See insets above NOTES 1 Requireme...

Page 9: ...ow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are placed in t...

Page 10: ...iances cannot accept responsibility for any damage to persons or to property arising from faulty connection or non connection to earth Before connecting installing or servicing the hob the plug should...

Page 11: ...a 7mm tube spanner Replace in or der with new injectors make sure the correct size injectors are used See data on underside of hob for size or refer to page 10 for chart 6 The regulator is required to...

Page 12: ...l Gas Burner Injector size mm MJ h NG 1 00 kPa Small 90 3 6 Medium 1 15 6 3 Large 1 55 10 8 Wok 1 75 13 2 Fish 1 55 10 8 ULPG Burner Injector size mm MJ h NG 2 75 kPa Small 0 55 4 0 Medium 0 66 6 3 La...

Page 13: ...ensure all control knobs are in the OFF position and the appliance has cooled completely Before any maintenance can be carried out you MUST disconnect the appliance from the electricity supply CLEANIN...

Page 14: ......