![background image](http://html1.mh-extra.com/html/omega/og60xa/og60xa_installation-and-operating-instructions-manual_4005519006.webp)
Natural gas: The regulator supplied MUST be fitted to the
½”
thread on the
elbow at the rear of the hot plate. The NG regulator MUST be checked and
adjusted to 1.0k Pa after installation.
ULPG: Can be connected directly with the inlet fitting. The pressure MUST be
checked to ensure the supply to the appliance is operating at 2.75kPa.
Clearance Above and Around Domestic Cookers:
•
200mm from the edge of the burner to combustible materials on vertical
sides of the appliance.
•
650mm to the underside of the overhead cupboards, shelving and
exhaust fans. Refer Figure2.
POSITIONING:
The appliance can be fitted into a working area as illustrated on the corresponding
figure (Fig. 1)
Apply the seal provided over the whole of the area perimeter.
FIGURE 1.
5
Summary of Contents for OG60XA
Page 14: ......