INSTALLATION IN KITCHEN CABINET WITH DOOR

  

The fixture has to be made according to specific requirements in order 

to prevent the gas burners from going out, even when the flame is 

turned down to minimum, due to pressure changes while opening or 

closing the cupboard doors. 
When the hob is installed above a cupboard with doors, a separate 

panel must be installed underneath it.  Leave a gap of at least 30 mm 

clearance between the cooker top and the surface of the panel (fig.13), 

which must be easily removable to allow sufficient access for any 

servicing procedures.  NOTE: When installing above a cupboard, a 

dividing shelf (as above) must be installed.  If installed above an under-

bench oven, this is not required.  Installation of an oven without a 

cooking fan underneath the hob is forbidden. 

 

PREPARING & PLACING THE HOB FOR INSTALLATION    

Every cooker top is provided with a set of tabs 

for fitting to the unit with thickness from 3 to 4 

cm and a seal with adhesive on one side. 

-Remove burners and grids. 

-Turn the cooker top over and rest the top face 

on a cloth. 

-Apply the self-adhesive seal “G” as illustrated 

in (fig.14). 

-Slot the cooker top into the unit and position. 

-Position the cooker top in the recess and 

secure by means of the brackets as shown in 

fig.15 (for 3 or 4 cm thick work top). 

 

DISCHARGING PRODUCTS OF COMBUSTION 

Extractor hoods connected directly to the outside must be provided, to allow the products of combustion of 

the gas appliance to be discharged (fig.16). 

If this is not possible, an electric fan may be used, attached to the external wall or the ceiling above the 

cooktop. The fan should have a capacity to circulate air at an hourly rate of 3-5 times the total volume of the 

kitchen (fig.17). 

 

 

 

 

 

 

Summary of Contents for OCG905FX

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Gas Cooktop OCG905FX...

Page 2: ......

Page 3: ...avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continua...

Page 4: ...lation it must be replaced by the manufacturer it s service agent or similarly qualified persons in order to prevent a hazard 7 The electrical and gas connections must be accessible after installation...

Page 5: ...on the front face e g 1 8 for 1 80mm injector Semi rapid Burner Rapid Burner Wok Burner Auxiliary Burner Semi rapid Burner Table of recommended pot sizes for each burner type Control Knob functions a...

Page 6: ...and one gasket fitted between the inlet and elbow The hob must be installed in a room with adequate ventilation see installation section N G Fit the supplied NG regulator to the elbow fitting using t...

Page 7: ...a test point REGULATING THE BURNER MINIMUM SETTING When switching from one type of gas to another the minimum flow rate must also be correct The flame should not go out even when passing suddenly fro...

Page 8: ...r coloured red After having installed the appliance the power switch or power plug must always be in an accessible position Electrical connection diagram N B For connections to the mains power supply...

Page 9: ...an underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhe...

Page 10: ...rature This will speed up the cooking time and is more efficient In the event of a power outage your gas cooktop can still be used Press turn the desired knob to the High position and light with a mat...

Page 11: ...pipes should be checked periodically for leakages see section on leak testing a minimum of every 12 months Lubrication of gas valves This can only be performed by an authorised person It may be requi...

Page 12: ...2018 10 15...

Reviews: