background image

 

GAS CONNECTIONS 

LOCAL AUTHORITY REQUIREMENTS 

Check Gas Type and specifications plate placed on the bottom face of the unit. All gas fitting work, service and 
repairs can only be performed by an authorized person in accordance with the current edition of AS/NZS5601 
and local gas regulations.  Failure to comply with this condition will render the warranty invalid.  Always unplug 
the appliance before carrying out any maintenance operations or repairs.  The walls of the units must not be 
higher than work top and must be capable of resisting temperatures of 75 above temperature.  Do not install the 
appliance near flammable materials (eg. curtains).  The final act of any installation or gas type conversion must 
be the full testing of this appliance, which includes leak testing, ignition of each burner and the functionality of the 
burners separately and together.   

INSTALLATION 

The appliance is predisposed and adjusted to operate with the gas indicated on the specifications plate (normally 
NG) applied onto the appliance. Please see gas rates summary information on the previous page. 
If the appliance must be operated with a gas different than that indicated on the plate, it is necessary to execute 
the following operations: 
-Gas connection including regulator (NG) to be changed. 
-Replacement of the injectors. 
-New gas label attached stating gas type. 
-Adjustment of minimum setting.  
-Check (and adjust if necessary) the gas pressure using a manometer connected to 6mm rubber tubing. 

GAS CONNECTION  

The connection must be made by a qualified gas fitter according to the relevant standard.  The gas connection is 
positioned 40mm from the left-hand side (from front), 30mm in from the back edge. 
The fitting is made up of one elbow and one gasket (fitted between the inlet and elbow). 
The hob must be installed in a room with adequate ventilation (see installation section). 

N.G.:  

Fit the supplied NG regulator to the elbow fitting using two spanners (note orientation of the NG regulator gas 
flow). 
Connect the other side of the NG regulator to the gas inlet pipe with the correct ½” BSPT thread connector using 
two spanners. 

UNIVERSAL L.P.G.: 

Connect the cooking hob inlet to the gas inlet pipe with the correct ½” BSPT thread connector (or using the 
appropriate adaptor) using two spanners.  Connect the other end of the pipe to the cylinder pressure regulator. 

ORIENTATION OF THE ELBOW 

The appliance is supplied with a gas connection oriented towards the centre of the cooking hob. The connection 
to the gas supply must be affected only from this side or in vertical position by turning the elbow downwards. To 
turn the elbow, first loosen the nut. Adjust the position of the elbow to the final position and retighten the nut. 
Make sure that there are no leakages by testing with a soapy solution and brush. 

IMPORTANT: 

Never attempt to turn the elbow without having first slackened off the relative lock nipple. 
It is recommended that the seal be replaced when it begins to show even the slightest deformation or 
imperfection. 

After connecting to the gas supply, check that the couplings are correctly sealed, using soapy solution and a 
brush, but never a naked flame. 
Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B Ø10mm, and no longer 
than 1m. Any hose assembly must be restrained from accidental contact with the flue outlet of an under-bench 
oven. 

OPERATIONS TO BE PERFORMED WHEN CONVERTING GAS TYPES: 

This operation can only be performed by an authorized person. 
Remove the gratings and the burner covers; 
Using a spanner, replace the nozzle injectors “J” (Fig.20) with either Natural Gas sized 
injectors or ULPG sized injectors. 

 

 

 

Summary of Contents for OCG60X

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Gas Cooktops OCG60X OCG64X ...

Page 2: ......

Page 3: ...o avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Omega reserves the right to alter specifications or appearances without notice CONTENTS SECTION PAGE NO Important Safety Instructions 3 Appliance Details 4 Gas Connections 5 6 E...

Page 4: ...llation it must be replaced by the manufacturer it s service agent or similarly qualified persons in order to prevent a hazard 7 The electrical and gas connections must be accessible after installation 8 Electrical connection must be made as per local wiring rules and regulations 9 Ensure that the kitchen is well ventilated or mechanical ventilation is in use while cooking on the gas cooktop 10 DO...

Page 5: ... e g 1 8 for Ø1 80mm injector Semi rapid Burner Semi rapid Burner Wok Burner Auxiliary Burner Table of recommended pot sizes for each burner type Control Knob functions are displayed around each knob as shown below Relevant Sizes LENGTH mm WIDTH mm HEIGHT mm Hob size 580 500 90mm Cut out size 563 483 BURNER TYPE NG DIAMETER OF POT mm ULPG DIAMETER OF POT mm Auxiliary Burner Ø80 TO Ø195 Ø80 TO Ø195...

Page 6: ... and one gasket fitted between the inlet and elbow The hob must be installed in a room with adequate ventilation see installation section N G Fit the supplied NG regulator to the elbow fitting using two spanners note orientation of the NG regulator gas flow Connect the other side of the NG regulator to the gas inlet pipe with the correct BSPT thread connector using two spanners UNIVERSAL L P G Con...

Page 7: ...f a test point REGULATING THE BURNER MINIMUM SETTING When switching from one type of gas to another the minimum flow rate must also be correct The flame should not go out even when passing suddenly from maximum to minimum flame To regulate the flame follow the instructions below Light the burner Set the gas valve to minimum On gas valves provided with adjustment screw in the centre of the shaft fi...

Page 8: ...or coloured red After having installed the appliance the power switch or power plug must always be in an accessible position Electrical connection diagram N B For connections to the mains power supply never use adapters reductions or multiple power points as these may overheat and catch fire In the event that installation should require modifications to the mains supply wiring system or if the pow...

Page 9: ...fan underneath the hob is forbidden PREPARING PLACING THE HOB FOR INSTALLATION Every cooker top is provided with a set of tabs for fitting to the unit with thickness from 3 to 4 cm and a seal with adhesive on one side Remove burners and grids Turn the cooker top over and rest the top face on a cloth Apply the self adhesive seal G as illustrated in fig 14 Slot the cooker top into the unit and posit...

Page 10: ...erature This will speed up the cooking time and is more efficient In the event of a power outage your gas cooktop can still be used Press turn the desired knob to the High position and light with a match Depress the knob after approx 3 seconds and continue to operate the burner Large utensils exceeding the recommended size can cause excessive heat to reflect back onto the appliance potentially dam...

Page 11: ...t pipes should be checked periodically for leakages see section on leak testing a minimum of every 12 months Lubrication of gas valves This can only be performed by an authorised person It may be required if the gas tap become stiff and difficult to turn Fault Possible cause corrective action No spark No ignition of gas Power outage appliance power turned off at isolation switch fuse blown tripped...

Page 12: ...2018 10 15 ...

Reviews: