background image

Mounting the 

O

perator:

operator
back plate

filler

fasten to jamb tubes

fasten along header

Notes:

-

E

nsure that door swings and latches easily before attempting to add operator

-

R

emove cover from operator

-

O

perator to wall mounting must be very strong!

-

A

ll loads from high winds & other overloads will be transferred thru the fasteners  to the wall

-

U

se appropriate fasteners and anchors for the type of wall being mounted to

-

M

ounting to drywall construction requires plwood backer inside the wall to attach operator

-

I

f the door framing is proud of the wall, place a filler allowing the operator to sit flat & plumb

-

A

ttach to vertical jamb tubes when mounting to curtain wall

drywall mounting

curtain wall mounting

plywood
backer 
board

drill & fasten
thru slots

O

 

M

 

E

 

G

 

A  A

 

U

 

T

 

O

 

M

 

A

 

T

 

I

 

C

 

S  2

 

0

 

1

 

8

V

 

2

 

.

 

0

Fasteners

120 VAC

Summary of Contents for OAL-100

Page 1: ...LOTHING CLEAR OF ALL MOVING PARTS ADJUSTMENTS TO BE PERFORMED BY APPROVED TECHNICIAN ONLY ALTERATION TO ANY COMPONENTS IS PROHIBITED REMOVE ANY MECHANICAL DEVICES OR LOCKS THAT INTERFERE WITH THE OPER...

Page 2: ...red thru the fasteners to the wall Use appropriate fasteners and anchors for the type of wall being mounted to Mounting to drywall construction requires plwood backer inside the wall to attach operato...

Page 3: ...into position and tighten grub screws Remove complete arm from the shaft Use jumper wire to hold open the motor Position the door in full open position Typically 90 to 105 degrees Reinstall arm onto...

Page 4: ...so roller contacts door Roller needs to be vertically centered in track Fasten track to door see diagram Place end caps on the track Install safety washer screw Adjust magnets see setting the magnets...

Page 5: ...dding inputs outputs Magnets must be properly positioned in order for operator to function see setting the magnets Full open position is limited by an internal stop not the magnets The magnets confirm...

Page 6: ...h Back Check Right Push Back Check Left Push Latch Right Push Latch Left Pull Back Check Left Pull Latch Right Pull Back Check Right Pull Latch Setting the Magnets O M E G A A U T O M A T I C S 2 0 1...

Page 7: ...Notes use terminals LOCK 24 to signal strike use 20 gauge wire Programming Functions Range Units Default 1 overload 50 99 50 2 activation delay 0 99 0 1seconds 0 3 back check 0 99 20 4 holding time 0...

Page 8: ...closed position screen will say DOOR CLOSED closed light will be illuminated DOOR CLOSED Step 2 Press MENU button to enter programming MAIN MENU Settings Step 2b Press SEL select DOOR CLOSED O M E G A...

Page 9: ...Press UP DN buttons to scroll Step 4 Press SEL to enter parameter Step 4b Press UP DN to change value SETTINGS 01 Overload 50 SETTINGS 01 Overload 50 O M E G A A U T O M A T I C S 2 0 1 8 V 2 0 SETTI...

Page 10: ...ced Relearn Step 1 From DOOR CLOSED screen Press MENU Press DN twice Step 1b Screen reads MAIN MENU Calibrate Press SEL twice for next screen SETTINGS 01 Overload 50 DOOR CLOSED MAIN MENU Calibrate X...

Page 11: ...U then ACT Screen reads CALIBRATE Step 3b Screen reads RELEASE STRIKE Learning Once one cycle is complete board has relearned itself CALIBRATE Relearn Next ACT RELEASE STRIKE Learning O M E G A A U T...

Page 12: ...er Cover Cover Snap cover onto backer plate Attach cover fasteners Stickers Apply warning stickers to door Refer to local codes for proper heights 58 5 42 AAADM Sticker O M E G A A U T O M A T I C S 2...

Reviews: