background image

5

CAUTION:

 The input module main circuit board and the option 

cards contain static sensitive components. Before handling the 

module or the cards, discharge static charges from your body by 

touching a grounded bare metal object. Handle the module by 

the rear plastic cover only, and the option cards by the board 

edges. Dirt, oil or other contaminants that contact the circuit 

boards or components can adversely affect circuit operation.

WARNING:

 Exposed line voltage exists on the input module main 

circuit board and the option cards. 

DO NOT

 apply power to the 

module OR load circuits until the module is properly installed 

in the LDP63000 case.

NOTE:

 All module and option card labels must be installed as 

shown for safety purposes.

Installing the Option Cards

Prior to installing the LDP63000 Display, it is recommended that the option 

cards be assembled first. This will allow you the opportunity to insure all the 

boards are fitted properly into their connectors. Refer to the literature 

enclosed with the option cards for installation instruction.

Removing The Input Module

To remove the input module from the 

LDP63000 Display, first remove all 

power and load circuits. Then insert a 

flat screwdriver blade (

3

/

16

" or 

1

/

4

") into the narrow slot 

between the LDP63000 

rear cover plate and the 

module’s plastic cover as 

illustrated in Figure 1. 

Twist the screwdriver in 

the direction shown to 

disengage the internal 

connectors while firmly 

squeezing and pulling 

back on the rear finger 

tabs (top and bottom). 

Carefully slide the module 

out of the case, keeping it 

properly aligned with the 

case opening.

1.0 ASSEMBLING THE DISPLAY

Reinstalling the Input Module

To reinstall the Input Module, align the module with the opening in the 

LDP63000 case, as illustrated. The module must be oriented as shown, 

with terminal #1 toward the top of the case. Carefully slide the 

module into the LDP63000 case. The LDP63000 and input 

module connectors will begin to engage about 

¼"

 from the 

bottom. At this point, apply a small amount of 

pressure to the rear of the input module to fully 

engage the connection. Be sure the module 

fully snaps into the slots at the rear of the 

LDP63000 case. The display is ready for 

installation.

Installing the Labels

Each option card and the input module are shipped with a connection label. 

These labels must be applied to the rear of the LDP63000 in the positions 

shown in the drawing.

CAUTION

:

1

2

3

4

5

6

7

8

9

10

11

DISCONNECT AL

L

POWER BEFORE INSTALLING OR REMOVING MODULE

SLOT

TWIST

!

WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM), INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT

(AT THE ARROW) AND TWIST IN THE DIRECTION SHOWN.

TO REMOVE MODULE:

RS485 COMMUNICATION

12

13

14

15

- B(-)

- A(+)

- COMM

- N/
C

1

2

3

4

5

6

7

8

9
10

11

~

~

AC

AC

85-250VAC

50/60H

z

14V
A

COMMUNICATION OPTION

ANALOG OUT OPTION

SETPOINT (SP) OPTION

SEE LITERATURE FO

R

JUMPER SELECTIO

N

SIGNAL INPUTS

USER INPUTS

VOLT/OHM

CURREN

T

+EXCITATIO

N

COMM

1

2

3

N/C

COMM

!

R

-

19

17

+

18

-

+

16

ANALOG OUTPUT

RLY3

25

21

RLY2

22

COMM

RLY1

20

QUAD RELAY S.P.

0-10
V

ANALO

G

OUTPUT

OUTPUT ANALO

G

0-20mA

24

23

COMM

RLY4

RELAYS RATE

D

3A @ 250VA

C

(RESISTIVE LOAD

)

MODULE

CONNECTOR

MODULE

REAR COVER

CAUTION

LABEL

MODULE

RETENTION

LATCH (TOP

AND BOTTOM)

OPTION CARD(S)

INSTALLED ON THIS SIDE

INPUT MAIN

CIRCUIT BOARD

(BOTTOM SIDE)

TERMINAL #1

MODULE AND

OPTION CARD(S) LABELS

(APPLY TO REAR COVER PLATE)

CAUTIO

N

DISCONNECT

ALL POWE

R

BEFORE

OPENIN

G

LDP63000 DISPLAY

REAR VIEW

METAL PANE

L

MUST BE

CONNEC

TED TO

!

E

MA2204X

Figure 2, Reinstalling an Input Module and Option Cards

8

SLOT

7

65

4

32

TWIS

T

Figure 1, Removing an Input Module

Summary of Contents for LDP63000

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide Shop online at LDP63000 Large Display Meter LP0687A...

Page 2: ...megashop cz Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega D...

Page 3: ...in the corresponding literature 1 DISPLAY 1 5 38 mm Red LED 5 Digit 19999 to 99999 2 POWER REQUIREMENTS AC Modules 85 to 250 VAC 50 60 Hz 18 VA DC Modules 11 to 36 VDC or 24 VAC 10 50 60 Hz 14 W 3 AN...

Page 4: ...that allows configuration of the LDP63000 meter from a PC The software offers standard drop down menu commands that make it easy to program the meter The unit program can then be saved in a PC file f...

Page 5: ...h the opening in the LDP63000 case as illustrated The module must be oriented as shown with terminal 1 toward the top of the case Carefully slide the module into the LDP63000 case The LDP63000 and inp...

Page 6: ...ment And Cleaning The display should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation Placing the system near devices that generate e...

Page 7: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 8: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: