6
Once assembled, the LDP63000 has all the same functions and capabilities of
our DP63x00 Series Intelligent Panel Meters. Therefore, you will find the
appropriate wiring and programming information in a separate manual packed
with your LDP63000 Display. Simply follow the instructions to wire and
program the display for your application.
2.0 INSTALLING THE DISPLAY
3.0 WIRING AND PROGRAMMING THE DISPLAY
LDP63000 DISPLAY INSTALLATION
The LDP63000 display is intended to be mounted into a panel or enclosure.
The display is provided with a gasket to provide a water-tight seal. The
recommended minimum panel thickness for NEMA 4/IP65 sealing
is 0.060" (1.57 mm).
For panel mounting, prepare the panel cut-out
to the dimensions shown. The supplied
template may be used to mark the cut-out
and hole locations on the panel. After the
panel cut-out has been deburred, slide the
panel gasket over the rear of the display
and onto the mounting studs. Insert the
display into the panel cut-out as
illustrated in Figure 3. Install six #
10-32 keps nuts (supplied) and tighten
evenly for uniform gasket compression.
Do not over-tighten the nuts.
By using additional mounting
accessories, the LDP63000 can be
surface-wall mounted, suspended, or
bottom mounted. Separate installation
instructions are provided with the
mounting accessories.
Environment And Cleaning
The display should be installed in a location that does not exceed the
maximum operating temperature and provides good air circulation. Placing the
system near devices that generate excessive heat should be avoided.
The bezel should be cleaned only with a soft cloth and neutral soap product.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate
the aging process of the bezel.
CAUTION:
1
2
3
4
5
6
7
8
9
10
11
DISCONNECT AL
L
POWER BEFORE INSTALLING OR REMOVING MODUL
E
SLOT
TWIS
T
!
WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM), INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT
(AT THE ARROW) AND TWEIST IN THE DIRECTION SHOWN
.
TO REMOVE MODULE:
RS485 COMMUNICATIO
N
12
13
14
15
- B(-)
- A(+)
- COMM
- N/
C
1
2
3
4
5
6
7
8
9
10
11
~~
AC
AC
85-250VAC
50/60H
z
14VA
COMMUNICATION OPTION
ANALOG OUT OPTION
SETPOINT (SP) OPTION
SEE LITERATURE FO
R
JUMPER SELECTIO
N
SIGNAL INPUTS
USER INPUTS
VOLT/OHM
CURRE
NT
+EXCI
TATIO
N
COMM
1
2
3
N/C
COMM
!
R
-
19
17
+
18
-
+
16
ANALOG OUTPU
T
RLY3
25
21
RLY2
22
COMM
RLY1
20
QUAD RELAY S.P.
0-10V
ANALOG
OUTPUT
OUTPUT ANALOG
0-20m
A
24
23
COMM
RLY4
RELAYS RAT
ED
3A @ 250V
AC
(RESISTIVE LOAD
)
MODULE
RETENTION
LATCH (TOP
AND BOTTOM)
MOUNTING
PANEL
PANEL
GASKET
FRONT
PANEL
MODULE RELEASE
FINGER TAB
(TOP & BOTTOM)
CASE
VENT
HOLES
REAR COVER PLATE
CAUTION
DISCONNECT
ALL POWER
BEFORE
OPENIN
G
CONNEC
TED TO
MUST BE
METAL P
ANE
L
MA2204
X
E
!
CONNECT THIS STUD
TO A PROTECTIVE
EARTHING SYSTEM
MOUNTING STUDS AND NUTS
(6 PLACES)
Figure 3, Installing The LDP63000 Into A Panel