The three types of Anti-Carjacking protection features are:

Step 3 

Within 5 seconds, perform an Emergency Override using the Valet Switch.  If the Secure

     Code has been customized, the correct number of Valet Switch presses must be made.

Step 2

 Turning the ignition back on.

Anti-Carjacking protection activated using a transmitter 

has the process start by pressing and

holding the transmitter’s “

III

” button for 3 seconds, but only if the vehicle’s ignition is on.  The Valet

Switch must be pressed within 60 seconds after this is done to cancel Anti-Carjacking. This is
programmable feature #23.

Anti-Carjacking protection activated an open door 

has the process start should a door be

opened after the vehicle is started and the engine is running.  The Valet Switch must be pressed within
60 seconds after the door is opened to cancel Anti-Carjacking.  This is programmable feature #22.

Anti-Carjacking protection activated by the vehicle’s ignition 

has the process start every

time the vehicle’s ignition is turned on.  The Valet Switch must be pressed within 60 seconds every time
the vehicle is started to cancel Anti-Carjacking.  This is programmable feature #21.

The K-9 features several security safeguards in one of the most vulnerable areas of any remotely

controlled system.  A basic safeguard is Code Jumping; as the transmitter sends a signal over the air
to operate the system, it is quite feasible for a thief to record these coded signals, for later playback to
the system to operate it and thus defeat it.  K-9’s Code Jumping renders such “code grabbing” devices
useless by randomly changing each signal that the transmitter sends.

Another weakness found in all remote-controlled security and keyless entry systems lies in their

Transmitter Protection

Page - 21

ability of being operated by more than one transmitter.  K-9 has patented, unique operations which
shows the number of transmitters capable of operating it, and also has a special warning should
transmitters have recently been programmed to operate the system.

Unauthorized Transmitter Alert 

sounds a brief series of siren chirps every time the vehicle’s

ignition is turned on, if a transmitter has been programmed, for 48 hours thereafter.  The 10 second
visual display of number of operating transmitters, described previously, will also increase to being
displayed for 90 seconds instead of 10 seconds.  48 hours after the programming occurred, the warning
chirps disappear and the Status Light flashing the number returns to being displayed for 10 seconds.

Automatic Transmitter Verification

  shows the total number transmitters which can operate the

system, by flashing the Status Light with this number for 10 seconds every time that the ignition key
is turned on.

Optional Backup Battery

The K-9 security system is designed for easy compatibility with a Backup Battery power option.

The Backup Battery option will allow the security system to operate its most vital functions even if
power is removed from the system's control module or if the vehicle's battery is disconnected. The
Omega dealer from which you purchased your vehicle security system can provide more details on the
exact operation of the system when it is equipped  with this option.

Summary of Contents for K9-Classic-E

Page 1: ...OWNER S MANUAL for K9 Classic E COLOR FRONT COVER COLOR BACK COVER from a separate file...

Page 2: ...8 5 663 704 5 729 191 5 818 329 5 612 578 5 739 747 382 558 385 878 5 750 942 5 739 748 5 719 551 406 107 701 285 5 973 592 5 982 277 5 986 571 6 011 460 6 037 859 6 049 268 6 130 605 6 130 606 6 140...

Page 3: ...y number When the desired musical tone has been the last one played you may leave the Echo undisturbed for 12 seconds until it chirps once Page 38 6 Press and release the button Each press of the butt...

Page 4: ...irporMutecanbechosenbypressingthe buttonfor1second B Hold this button for 5 seconds to enter programming mode OR 1 Press and hold the P button 2 After 5 seconds the Echo chirps twice release the P but...

Page 5: ...nted by the installer If the optional 2 way Echo controller is used the Status Light and Valet Switch are likely on the window mounted Echo transceiver unit impact causing the system to prewarn the im...

Page 6: ...sed as desired Using the K 9 System Page 35 The digit readout is a clock with AM and PM indication This readout also shows how many transmitters transceivers can operate the system The DISARM will als...

Page 7: ...he K 9 system s separate arm lock and disarm unlock button design allows repetitive operation if already armed pressing the arm lock button will simply rearm the system and vice versa when pressing th...

Page 8: ...ff When it is first triggered the Status Light changes it flash pattern and the doors will automatically relock Should a door be open when the system triggers it will wait until the door is closed and...

Page 9: ...ng and releasing its disarm unlock button This is the normal daily use method Press and release the transmitter s disarm unlock button once to instantly disarm the system disengaging the starter inter...

Page 10: ...change to flashing two to four times between pauses as a Zone Violation code to indicate which protection circuit triggered the system 2 flashes hood trunk 3 flashes doors 4 flashes optional sensor Th...

Page 11: ...The above Emergency Override instructions reflect the as received from the factory default setting Lower Right III Button highest chirp volume 50mS system responds with 4 chirps Lower Left II Button m...

Page 12: ...ress the transmitter s arm lock button to select the Pulsed Horn setting or press the disarm unlock button will configure the Steady Siren setting Panic and in association with the transmitter button...

Page 13: ...et Switch is an important part of your K 9 system be sure that you know its location orized Transmitter Alert nor will it affect the chirps used in transmitter or features programming Page 28 Feature...

Page 14: ...w seconds the siren will stop sounding and the unit will disarm Page 27 Feature 9 Ignition Off Unlock 2 Factory Default Setting Off Explained in the previous feature if Driver s Door Priority is insta...

Page 15: ...icates which protected zone caused the alarm condition Page 26 Feature 3 Automatic Rearming Factory Default Setting Off Automatic Rearming described on page 10 prevents the system from becoming accide...

Page 16: ...n and will become armed after the 30 second countdown expires This Audible and Visual Indications Page 25 The Programmable Features To custom program a new SecureCode Step 4 Continue to configure stag...

Page 17: ...eature page 20 21 has been activated 10 Three siren chirps upon arming the system The Zone Bypass feature is indicating that the system is arming but bypassing a violated protected zone 11 Three siren...

Page 18: ...his Prewarning circuit has been triggered five times it will automatically shutdown until the alarm system is disarmed then armed This willpreventthesecuritysystemfrombeinganuisancetothegeneralpublic...

Page 19: ...led stater interrupt will engage Once the system enters the alarm condition it will not respond to the transmit ter nor will the system reset automatically after 60 seconds and it can only be disengag...

Page 20: ...K 9 s Code Jumping renders such code grabbing devices useless by randomly changing each signal that the transmitter sends Another weakness found in all remote controlled security and keyless entry sys...

Reviews: