SecureCode:

  “SecureCode” allows the user to customize the number of Valet Switch presses

which are required to successfully perform an Emergency Override.  The basic Emergency Override
procedure is described on page 11
.  Instead of a single “1 press” of the Valet Switch which would
be required in order to perform an Emergency Override, two stages of Valet Switch presses must be
made.  In each of the two stages, the Valet Switch will need to be pressed 1 through 9 times, as
programmed by the user.  This is the Emergency Override procedure if the system has programmed with
a customized SecureCode:

 described on page 11, enter the vehicle (the system will most likely activate or already be activated to
a triggered alarm condition.  Using the ignition key, turn the vehicle’s ignition switch on, and within
5 seconds press and release the Valet Switch.  The system will disarm.

Once the system is disarmed, if Valet Mode is desired, just press and hold the Valet Switch for 2

seconds to place the system into Valet Mode.  Should a mistake be made entering the SecureCode, after

Step 1

With the system in the armed condition, enter the vehicle via the driver's door (be aware that
the system will activate to an alarm condition when the door is opened).

Step 2

Using the ignition key, turn the vehicle’s ignition switch on.

Step 3

Within 5 seconds press and release the Valet Switch the same number of times that have been
programmed for stage #1.

Step 4

After a few seconds, the siren will stop sounding, chirp once, and then resume sounding.

Step 5

Now, within 5 seconds press and release the Valet Switch the same number of times that have
been programmed for stage #2.  Within a few seconds the siren will stop sounding, and the unit
will disarm.

Page - 27

Feature #9   Ignition Off Unlock #2

(Factory Default Setting  Off)

Explained in the previous feature,  if Driver’s Door Priority is installed this feature controls the
automatic unlocking when the ignition key is turned off of all doors except the driver’s door.

Feature #10   Open Door Bypass of Ignition Locking

 

(Factory Default Setting  On)

This feature cancels the automatic locking or unlocking of the vehicle’s doors should one of the doors
is open when the ignition switch is turned on or off.

Feature #7   Doors Lock With Ignition On

 (Factory Default Setting  On)

This feature has the system automatically lock the vehicle’s doors every time the ignition key is turned
on.  An exception would be if feature #10 is turned on (“Open Door Bypass of Automatic Locking”),
and a door is open when the ignition key is turned on.

Feature #8   Ignition Off Unlock #1

(Factory Default Setting  On)

Similar to the previous feature, this feature automatically unlocks the vehicle’s doors every time the
ignition key is turned off, with the same exception regarding a door being open when the ignition is
turned off, and feature #10 being on.  On Crime Guard models with “Driver Door Priority Unlocking”,
this feature may control all doors’ unlock operation, or only the driver’s door.  If the later, the next
feature controls the ignition key unlocking of the remaining doors.

Feature #11   Confirmation Chirps

(Factory Default Setting  On)

This feature removes the system’s 1 arming chirp and 2 disarming confirmation chirps.  When this
feature is used to remove these chirps, the system will still have 3 chirps upon arming if a protected zone
is violated, and still have 4 chirps upon disarming if the system was previously activated.  Using this
feature to turn off the arm and disarming chirps will also not affect the Prewarning operation, Unauth-

Summary of Contents for K9-Classic-E

Page 1: ...OWNER S MANUAL for K9 Classic E COLOR FRONT COVER COLOR BACK COVER from a separate file...

Page 2: ...8 5 663 704 5 729 191 5 818 329 5 612 578 5 739 747 382 558 385 878 5 750 942 5 739 748 5 719 551 406 107 701 285 5 973 592 5 982 277 5 986 571 6 011 460 6 037 859 6 049 268 6 130 605 6 130 606 6 140...

Page 3: ...y number When the desired musical tone has been the last one played you may leave the Echo undisturbed for 12 seconds until it chirps once Page 38 6 Press and release the button Each press of the butt...

Page 4: ...irporMutecanbechosenbypressingthe buttonfor1second B Hold this button for 5 seconds to enter programming mode OR 1 Press and hold the P button 2 After 5 seconds the Echo chirps twice release the P but...

Page 5: ...nted by the installer If the optional 2 way Echo controller is used the Status Light and Valet Switch are likely on the window mounted Echo transceiver unit impact causing the system to prewarn the im...

Page 6: ...sed as desired Using the K 9 System Page 35 The digit readout is a clock with AM and PM indication This readout also shows how many transmitters transceivers can operate the system The DISARM will als...

Page 7: ...he K 9 system s separate arm lock and disarm unlock button design allows repetitive operation if already armed pressing the arm lock button will simply rearm the system and vice versa when pressing th...

Page 8: ...ff When it is first triggered the Status Light changes it flash pattern and the doors will automatically relock Should a door be open when the system triggers it will wait until the door is closed and...

Page 9: ...ng and releasing its disarm unlock button This is the normal daily use method Press and release the transmitter s disarm unlock button once to instantly disarm the system disengaging the starter inter...

Page 10: ...change to flashing two to four times between pauses as a Zone Violation code to indicate which protection circuit triggered the system 2 flashes hood trunk 3 flashes doors 4 flashes optional sensor Th...

Page 11: ...The above Emergency Override instructions reflect the as received from the factory default setting Lower Right III Button highest chirp volume 50mS system responds with 4 chirps Lower Left II Button m...

Page 12: ...ress the transmitter s arm lock button to select the Pulsed Horn setting or press the disarm unlock button will configure the Steady Siren setting Panic and in association with the transmitter button...

Page 13: ...et Switch is an important part of your K 9 system be sure that you know its location orized Transmitter Alert nor will it affect the chirps used in transmitter or features programming Page 28 Feature...

Page 14: ...w seconds the siren will stop sounding and the unit will disarm Page 27 Feature 9 Ignition Off Unlock 2 Factory Default Setting Off Explained in the previous feature if Driver s Door Priority is insta...

Page 15: ...icates which protected zone caused the alarm condition Page 26 Feature 3 Automatic Rearming Factory Default Setting Off Automatic Rearming described on page 10 prevents the system from becoming accide...

Page 16: ...n and will become armed after the 30 second countdown expires This Audible and Visual Indications Page 25 The Programmable Features To custom program a new SecureCode Step 4 Continue to configure stag...

Page 17: ...eature page 20 21 has been activated 10 Three siren chirps upon arming the system The Zone Bypass feature is indicating that the system is arming but bypassing a violated protected zone 11 Three siren...

Page 18: ...his Prewarning circuit has been triggered five times it will automatically shutdown until the alarm system is disarmed then armed This willpreventthesecuritysystemfrombeinganuisancetothegeneralpublic...

Page 19: ...led stater interrupt will engage Once the system enters the alarm condition it will not respond to the transmit ter nor will the system reset automatically after 60 seconds and it can only be disengag...

Page 20: ...K 9 s Code Jumping renders such code grabbing devices useless by randomly changing each signal that the transmitter sends Another weakness found in all remote controlled security and keyless entry sys...

Reviews: