14
Resistance
Range
Resolution
Accuracy
lnput
600
0.01
± ( 0.3%
red+20d )
-3.0Vdc
6k
0.1
± ( 0.3%
red+10d )
-1.2Vdc
60k
1
600k
10
6M
100
± (1.0% red+10d )
60Mv
1k
± (3.0% red+20d )
Overload protection: 600V DC or 600V AC RMS
Continuity Test
Range
Audible
Threshold
Response
Time
Open
Circuit
600
Less than
40
Approx.
100ms
-3.0Vdc
Overload protection: 600V DC or 600V AC RMS
Diode Test
Range
Resolu-
tion
Accuracy
Test
Current
Open
Circuit
2V
1mV
± (2.0%
red+10d)
0.5mA
3.0Vdc
typical
Audible indication: Less than 0.05V
Overload protection: 600V DC or 600V AC RMS
Conductance (6000 counts)
Range
Resolu-
tion
Accuracy
Open
Circuit
60ns
0.01ns
± (1.0%
red+10d )
-0.7Vdc
Equivalent Resistance Range: 16.7M to
100G
(S = Siemens = 1 / ), (0.01ns = 100Gs ), (0.1ns = 10G
), ( 1ns = 1000M ), (10ns = 100M ), (60.0ns =
16.7M )
Overload protection: 600V DC or 600V AC RMS