background image

OMEGAnet

SM

 On-Line Service

http://www.omega.com

Internet e-mail

[email protected]

Servicing North America:

USA:

 ISO 9001 Certified

Canada:

One Omega Drive, Box 4047

976 Bergar

Stamford, CT 06907-0047

Laval (Quebec) H7L5A1

Tel: (203) 359-1660

Tel: (514) 856-6928

FAX: (203)359-7700

FAX: (514) 856-6886

e-mail: [email protected]

e-mail: [email protected]

omega.com

TM

For immediate technical or application assistance:

USA and Canada:

Mexico and Latin America:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Tel: (95) 800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

FAX: (95) 203-359-7807

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

En Español: (203) 359-7803

TELEX: 996404  EASYLINK: 62968934  CABLE: OMEGA

e-mail: [email protected]

Servicing Europe:

Benelux:

Germany/Austria:

Postbus 8034, 1180 LA Amstelveen,

Daimlerstrasse 26, D-75392

The Netherlands

Deckenpfronn, Germany

Tel: (31) 20 6418405 FAX: (31) 20 6434643

Tel: 49 (07056) 3017 FAX: 49 (07056) 8540

Toll Free in Benelux: 06 0993344

Toll Free in Germany: 0800 82 66342

e-mail: [email protected]

e-mail: [email protected]

Czech Republic:

United Kingdom:

 ISO 9002 Certified

ul. Rude armady 1868, 733 01 Karvina-

One Omega Drive

Hranice, Czech Repubic

Riverbend Technology Centre Northbank, Irlam,

Tel: 420 (69) 6311627 FAX: 420 (69) 6311114

Manchester, M44 5EX, England

e-mail: [email protected]

Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622

France:

9, rue Denis Papin, 78190 Trappes

Toll Free in England: 0800-488-488

Tel: (33) 130-621-400 FAX: (33)130-699-120

e-mail: [email protected]

Toll Free in France: 0800-4-06342

e-mail: [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification
of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains,
and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected application.

Summary of Contents for HHM29

Page 1: ...OMEGA HHM29 Digital Multimeter...

Page 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Page 3: ...across a high voltage high energy power source when the meter is set up for mA measurement may be very hazardous 3 Turn off power to the circuit under test before cutting unsoldering or breaking the...

Page 4: ...age Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 23 C 5 C 75 relative humidity Safety According to EN61010 1 protection class II overvoltage categor...

Page 5: ...0MW Overload protection 1000VDC or 750VAC rms AC VOLTS 50Hz 2KHz Ranges 430mV 4 3V 43V 430V 750V Resolution 100 V Accuracy Input impedance 10MW Overload protection 1000VDC or 750VAC rms Range 50Hz 100...

Page 6: ...anges 430 A 43mA 430mA 10A Resolution 100nA Accuracy 1 0 rdg 2dgts on 430 A 43mA ranges 2 5 rdg 2dgts on 430mA 10A ranges Burden voltage 1 4V on all ranges execpt 1 5V on 10A range Input protection 0...

Page 7: ...IC TEST Threshold Logic Hi 2 8 0 8V Logic Lo 0 8 0 5V Frequency response 20MHz Detectable pulse width 25nS Pulse limits 30 70 duty Overload protection 500VDC or AC rms TEMPERATURE Ranges 20 C to 1300...

Page 8: ...F 430 F Resolution 1pF Accuracy 5 0 rdg 10dgts Test frequency 4300pF 43nF ranges 1KHz 430nF 4 3 F ranges 270Hz 430 F range 27Hz INDUCTANCE Ranges 4 3mH 43mH 430mH 4 3H 43H Resolution 1 H Accuracy 5 0...

Page 9: ...utton the range and the input range annunciator increments and a new value is displayed To exit the Manual Range mode and return to autoranging press and hold down RANGE button for 2 seconds The AUTO...

Page 10: ...display and store the displayed reading as a reference value The relative mode annunciator D is displayed Press REL D again to exit the relative mode D D D D D SET Button The Relative value can also...

Page 11: ...onnect the red test lead to the 10A jack and the black test lead to the COM jack 4 Remove power from the circuit under test and open the normal circuit path where the measurement is to be taken Connec...

Page 12: ...ading is obtained with both lead connections the junction may be shunted by a resistance of less than 1kW In this case the diode must be disconnected from the circuit for accurate testing Capacitance...

Page 13: ...o the COM jack 3 Connect the red test lead to the test point and the black lead to the common buss of the logic circuit 4 A on the display indicates TTL logic high and a indicates a TTL logic low Both...

Page 14: ...se Remove the battery from battery contacts Fuse Replacement If no current measurements are possible check for a blown overload protec tion fuse There are two fuses F1 for the mA jack and F2 for the 1...

Page 15: ...meter before making other types of measure ments If the equipment is used in a manner not specified in this manual the protection provided by the equipment may be impaired Do Not Operate the meter in...

Page 16: ...14 Back View Of Supermeter Battery Door Open Fuse 10A 600V Battey 9V Fuse 0 5A 250V...

Page 17: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Page 18: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: