![background image](http://html1.mh-extra.com/html/omega/hhm17/hhm17_user-manual_3997369007.webp)
5
DIODE TEST
Test current: 1.0mA±0.6mA
Accuracy: ±(3.0%rdg + 3dgts)
Open circuit volts: 3.0Vdc typical
Overload protection: 500VDC or AC rms
CAPACITANCE
Ranges: 4nF,40nF,400nF,4µF,40µF
Accuracy: ±(2.0%rdg+20dgts) on 4n Frange(use 0ADJ)
±(2.0%rdg + 4dgts) on 40nF to 40µF ranges
±(5.0%rdg + 4dgts) above 40µF
Overload protection: 500VDC or AC rms
FREQUENCY (Autoranging)
Ranges: 100Hz,1KHz,10KHz,100KHz,700KHz
Resolution: 0.01Hz
Accuracy: ±(0.05%rdg + 2dgts)
Sensitivity: 1.0V rms min
Overload protection: 500VDC or AC rms
TRANSISTOR hFE
Ranges: 0 - 1000
Base current: 10µAdc approx. (Vce=3.0Vdc)