background image

OMEGAnet

SM

 On-Line Service

http://www.omega.com

Internet e-mail

[email protected]

Servicing North America:

USA:

 ISO 9001 Certified

Canada:

One Omega Drive, Box 4047

976 Bergar

Stamford, CT 06907-0047

Laval (Quebec) H7L5A1

Tel: (203) 359-1660

Tel: (514) 856-6928

FAX: (203)359-7700

FAX: (514) 856-6886

e-mail: [email protected]

e-mail: [email protected]

omega.com

TM

For immediate technical or application assistance:

USA and Canada:

Mexico and Latin America:

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

SM

Tel: (95) 800-TC-OMEGA

SM

Customer Service: 1-800-622-2378 / 1-800-622-BEST

SM

FAX: (95) 203-359-7807

Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

SM

En Español: (203) 359-7803

TELEX: 996404  EASYLINK: 62968934  CABLE: OMEGA

e-mail: [email protected]

Servicing Europe:

Benelux:

Germany/Austria:

Postbus 8034, 1180 LA Amstelveen,

Daimlerstrasse 26, D-75392

The Netherlands

Deckenpfronn, Germany

Tel: (31) 20 6418405 FAX: (31) 20 6434643

Tel: 49 (07056) 3017 FAX: 49 (07056) 8540

Toll Free in Benelux: 06 0993344

Toll Free in Germany: 0800 82 66342

e-mail: [email protected]

e-mail: [email protected]

Czech Republic:

United Kingdom:

 ISO 9002 Certified

ul. Rude armady 1868, 733 01 Karvina-

One Omega Drive

Hranice, Czech Repubic

Riverbend Technology Centre Northbank, Irlam,

Tel: 420 (69) 6311627 FAX: 420 (69) 6311114

Manchester, M44 5EX, England

e-mail: [email protected]

Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622

France:

9, rue Denis Papin, 78190 Trappes

Toll Free in England: 0800-488-488

Tel: (33) 130-621-400 FAX: (33)130-699-120

e-mail: [email protected]

Toll Free in France: 0800-4-06342

e-mail: [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification
of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains,
and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected application.

Summary of Contents for HHM17

Page 1: ...OMEGA HHM17 Digital Multimeter...

Page 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Page 3: ...cross a high voltage high energy power source when the meter is set up for mA measurement may be very hazardous 3 Turn off power to the circuit under test before cutting unsoldering or breaking the ci...

Page 4: ...c Analog display Operating Environment 0 C to 40 C at 70 relative humidity Storage Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 23 C 5 C 75 relative...

Page 5: ...ge Input impedance 10MW Overload protection 600VDC or AC rms AC VOLTS Ranges 400mV 4V 40V 400V 600V 400mV only Manual 50Hz 100Hz Resolution 100 V Accuracy Input impedance 10MW Overload protection 600V...

Page 6: ...racy 1 0 rdg 4dgts on mA ranges 3 0 rdg 4dgts on 10A range Input protection 0 5A 250V fast blow ceramic fuse 10A 600V fast blow ceramic fuse RESISTANCE Ranges 400W 4KW 40KW 400KW 4MW 40MW Accuracy 0 3...

Page 7: ...Accuracy 2 0 rdg 20dgts on 4n Frange use 0ADJ 2 0 rdg 4dgts on 40nF to 40 F ranges 5 0 rdg 4dgts above 40 F Overload protection 500VDC or AC rms FREQUENCY Autoranging Ranges 100Hz 1KHz 10KHz 100KHz 70...

Page 8: ...old down the PON button while turning the meter from OFF to on and select a function the automatic power off feature is disabled MEM Button When MEM button is pressed the MEM annunciator is displayed...

Page 9: ...LD annunciator turns on Push the button to cycle through the minimum MIN maximum MAX and present readings The MIN or MAX annunciator turns on to indicate what value is being displayed In the MIN MAX R...

Page 10: ...r the MIN MAX Recording mode In the MIN MAX Recording mode press HOLD button to stop the recording of readings press HOLD again to resume recording RANGE Button Press RANGE button to select the Manual...

Page 11: ...ignisdisplayedfornegativepolarity positivepolarityisimplied Current Measurements 1 Set the Function Range switch to the desired current range and press the Blue toggle button to select AC or DC 2 For...

Page 12: ...y if the resistance is less than 40W WARNING The accuracy of the functions might be slightly affected when exposed to a radiated electromagnetic field environment eg radio telephone or similar Diode T...

Page 13: ...o the Cx socket 4 Read the capacitance directly from the display Transistor Gain Measurements 1 Set the Function Range switch to the desired hFE range PNP or NPN type transistor 2 Never apply an exter...

Page 14: ...battery from battery contacts Fuse Replacement If no current measurements are possible check for a blown overload protec tion fuse There are two fuses F1 for the mA jack and F2 for the 10A jack For a...

Page 15: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Page 16: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: