Operating Instructions
3-10
4.
Press VIEW or SET to save the Open Lead Detection setting and exit the Setup
Menu.
a.
Alternatively, to disregard the Open Lead Detection setting and exit the
Setup Menu, press CLR.
Clear Function
From active measurement or hold mode, press
to clear the statistics registers and
begin a new statistics session. The LCD display will indicate CLr to confirm the action, and
return to active measurement mode.
Pressing
deletes all measurement data currently saved in the instrument’s
internal memory. To prevent data loss, connect to the OMEGA Thermometer Link
mobile app and OMEGA Data Cloud to upload saved data before performing this
From the Setup Menu, press
to disregard changes to the current parameter value and
exit the Setup Menu.
Real-Time Clock
The real-time clock is displayed in the lower-left of the display. In active measurement
mode, the clock displays the current time in 24-hour format (hh:mm:ss). See Section 3.3,
Setup Menu to set the date and clock.
When reviewing saved measurement data, the clock alternates between the currently
displayed data point time stamp and date stamp. The CLK indicator is lit when the time
stamp is displayed, and is off when the date stamp is displayed. When viewing statistics, the
clock displays the elapsed time of the current statistics session.
Measurement Data Collection Overview
The data collection features of the OMEGA Data Thermometers accurately record and store
accurate time stamped measurements at the touch of a button. Saved data can be reviewed
on the device, or uploaded to the OMEGA Data Cloud via the OMEGA Thermometer Link
mobile app.
Measurement data is collected automatically at user-programmed intervals, or manually as
desired by the user. All saved measurements can be viewed directly on the instrument,
monitored in real-time with the mobile app, or reviewed, analyzed, and downloaded from
the OMEGA Data Cloud.
Each saved measurement includes a time and date stamp based on the date and time
programmed into the instrument. Through the mobile app and OMEGA Data Cloud, data
collection sessions can be associated with user-customizable locations to establish an
auditable record for a given asset, product, batch, bin, etc.
Measurement Data Collection Configurations
Data collection can be accomplished using three distinct configurations to provide the most
flexibility and adaptability based on equipment availability and internet or cellular access.
Summary of Contents for HH931T
Page 39: ...Appendices B i B EXPANDED INSTRUMENT UNCERTAINTIES Thermocouple Type B ...
Page 40: ...Appendices B ii Thermocouple Type E ...
Page 41: ...Appendices B iii Thermocouple Type J ...
Page 42: ...Appendices B iv Thermocouple Type K ...
Page 43: ...Appendices B v Thermocouple Type N ...
Page 44: ...Appendices B vi Thermocouple Type R ...
Page 45: ...Appendices B vii Thermocouple Type S ...