6. Explanations of Toolbar 

 

 

6.1 

 Communication port 

setup

 dialog 

box. 

 

 Auto connection 

  : Click the bottom let sys-

tem select communication port automati-
cally. 
 

 Manual connection 

 

Select communication port and baud rate 
manually. (Wireless mode, please select 
38400 bps, USB mode, please refer to op-
eration manual). 
After click on “Do not show this window 

automatically” it will not bring up the 
dialog box automatically. It will only 
function when you call from the Setup. 
For first use, after communication port 
setting following dialogue box comes up. 

 Set meter ID and CH (Only for wireless 

models)

 

 

1. When message “Meter is found on 

CH=00, ID=00” is shown in dialogue 
box. 
Please change ID and CH numbers to   
other numbers preferred (ID from 1 to   
127, and CH from 1 to 50). 
(Model HH8XXE: CH from 1 to 4). 
Click “Set” to connect. 

2. When message “Meter not found on   

CH=00, D=00” is shown in dialogue 
box, please reset ID and CH as follow-
ing:  

I.

 

Turn off the meter. 

II.

 

Press and hold wireless starting key 
(

) and press power on/off 

key (

)for longer than five sec-

onds. Display will shown “00”. 

III.

 

Turn on wireless function by press-
ing wireless starting key (

). 

IV.

 

Click “Relink”. 

V.

 

Repeat 1. 

 

Note 
If there are more than one wireless 
transceivers operate at same location. 
1. Different doungle ID’s should be 

given. 

2. Distance between 2 doungles must be 

more than 30 cm. (12 inches) 

6.2 

 Environment selection settings dialog 

box. 

 

 Time setting 

 

Only available for meters with time set-
ting function. 
Click “SET” synchronize the clock in me-
ter with the time of PC. 
 

 Doungle ID setting   

 

Only available for meters with wireless 
function. 

 

 

 

Meter ID and CH setting

 

 

CH setting only available for meters with 
wireless function. 
 

 Sound of Hi/Lo limit setting

 

 

Click data folder icon on the right

and select sound effect. (Only use WAVE 
format). 
 

 Hi/Lo limit setting

 

 

1. Setting the Limits.   
  Audio alarm will be actuated, when 

measurements are out of limits. 

2. Background color of each channel can 

be selected. 

 

 

  Enable or disable the function which stop 

data logging when battery is low. 
 

6.3 

  Relative dialog box. 

 

Summary of Contents for HH800-SW

Page 1: ...end Technology Centre Kingdom Northbank Irlam Manchester ISO 9002 M44 5BD United Kingdom Certified Tel 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales ome...

Page 2: ...t 3 Select Search removable media floppy CD ROM and click Next 4 Installation 5 Complete installation click Finish to com plete 6 Appear found new hardware select No not this time and click Next 7 Sel...

Page 3: ...0SW HH800SW Description of PC software 1 Following window comes up automatically after PC software turn on 2 For first time use following communication port setup dialog box Comes up automatically 3 F...

Page 4: ...rn off the meter II Press and hold wireless starting key and press power on off key for longer than five sec onds Display will shown 00 III Turn on wireless function by press ing wireless starting key...

Page 5: ...e data file Click OK to start recording Stop data logger Click to stop data logging and save the data Return to the main window after data logging ended File Exit 6 5 To export data stored in meter to...

Page 6: ...nce with the in structions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cau...

Page 7: ...ionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all war...

Reviews: