background image

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month 

grace period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This 

ensures that OMEGA’s customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for  

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 

prior written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the 

following information available BEFORE  

contacting OMEGA:
1.  Purchase Order number under which the product

was PURCHASED,

2.  Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems

relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult OMEGA 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems

relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. 

BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED 

RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID 

PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return 

package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit. 

 

Summary of Contents for FPD3100-D Series

Page 1: ...e mail info omega com For latest product manuals www omegamanual info FPD3100 D and FPD3100 D A Series 12mm LC Digital Display with Analog Output Options Shop online at omega com User sGuide...

Page 2: ...6 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in this document is believed...

Page 3: ...ge 6 Wiring Diagram Page 7 Parts Listing Page 7 Technical Specifications Page 8 Type FPD3100 D A Digital Register Program Overview Page 10 Set up Functions Page 11 13 Wiring Diagram Page 13 Outputs Pa...

Page 4: ...polypropylene housing offers IP65 environmental protection Configuration of the unit The FPD3100 Series has been designed to be implemented in many types of applications For that reason a SETUP level...

Page 5: ...seconds Default 35 4 METER 4 METER SIGNAL Reed Switch Only 4 1 K FACTOR Pulses per Unit 0000 000 to 9999 999 5 OTHERS 6 1 TYPE DR 6 2 SOFTWARE VERSION 03 xx xx 6 3 SERIAL NO xxxxxxx GENERAL Configura...

Page 6: ...per litre and unit adjustment is done automatically TIME UNIT 3 2 The flow rate can be calculated per second SEC minute MIN hour HR or day DAY DECIMALS 3 3 This setting determines for flow rate the n...

Page 7: ...nput this sensor has been selected as the most common sensor and requires very little power with small effect on battery life The 2 position terminal block is not polarity conscious so the reed switch...

Page 8: ...A size Terminal connections Type Terminal strip Wire max 1mm Data protection Type Backup of all settings and running totals in flash memory Environment Electromagnetic compatibility Compliant ref EN...

Page 9: ...9 NOTES...

Page 10: ...m3 US GAL UK GAL US bbl UK bbl OIL bbl L 22 DECIMALS 0 1 2 3 0 FLOWRATE DEFAULT 31 UNIT L m3 US GAL UK GAL US bbl UK bbl OIL bbl L 32 TIME UNIT sec min hour min 33 DECIMALS 0 1 2 3 0 34 CALCULATION p...

Page 11: ...entered in 5 1 should be in pulses per litre and unit adjustment is done automatically TIME UNIT 3 2 The flow rate can be calculated per second SEC minute MIN hour HR or day DAY DECIMALS 3 3 This sett...

Page 12: ...endant upon SETUP 21 and 22 but are not displayed MAXIMUM FLOWRATE 6 2 Enter here the flow rate at which the output should generate the maximum signal 20mA or 10V in most applications at maximum flow...

Page 13: ...l be emptied It might be that pulses will be missed due to a buffer overflow so it is advised to program this setting within it s range PULSE PER 7 3 According to the measurement unit settings for tot...

Page 14: ...e output must be programmed as follows In menu 7 1 set 2222 22 In menu 7 2 set 10 or more 10mS or more if needed In menu 7 3 set 1 00 Example Pulse Alarm Output Setup Passive 4 20mA setup 9 10 Pulse O...

Page 15: ...15 FPD3100 D A DIGITAL REGISTER Parts Description...

Page 16: ...years 20 C ER17505 3 6V A size Terminal connections Type Terminal strip Wire max 1mm Data protection Type Backup of all settings and running totals in flash memory Environment Electromagnetic compati...

Page 17: ...the 4 00mA and 20 00mA levels precisely within set up Minimum operating voltage 8V DC Power supply 18 30V DC Switch outputs Function One scaled pulse output transmitting accumulated total One high fl...

Page 18: ...n 33 decimals 0000000 34 calculation pulses 010 35 cut off time 30 0 sec 4 Alarm 41 alarm disabled 42 flow zero on 43 alarm low 0 44 alarm high 9999 45 delay alarm 0 5 FLOWMETER 51 k factor 1 000 6 AN...

Page 19: ...PD3100 series is available with a Wall Mount Bracket option for applications requiring remote mount display Both the models D and D A are available with this option Following is a dimensional drawing...

Page 20: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 21: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...