FMG490 INSTRUCTIONS

Page 20 

OPERATION

The EXIT tab in the MAIN MENU has a second function. If, 

instead of using the hold and tap sequence to return to the 

HOME screen, you tap 

 five times, you will be redirected 

to a SUBMENU screen from which you can access several 

more options.
Navigation in this SUBMENU is the same as for the MAIN 

MENU.  Whenever  you  wish,  go  to  the  EXIT  tab  in  the 

SUBMENU and perform the hold and tap sequence to 

return to the MAIN MENU.

 

INFO

 COMM MBID

FL DIR

SAMP

HPOLL

FOUT

EXIT

PRESS 

  +  

 TO VIEW INFO 

ABOUT METER

Sub-Menu

INFO:   Meter model number, serial number, and firmware 

version.

COMM:  Modbus

®

 baud rate and parity. (Not available on 

battery only units.)

MBID:   Modbus

®

 address (Not available on battery only 

units.)

HPOLL:  HART Address (Not available on  battery only 

units.)

EXIT:   Return to MAIN MENU.

T UNIT

View or change TOTAL 

volume units

R UNIT

View or change flow 

RATE units

SET P

View or change pulse 

output scaling

DAMP

View or change # of 

samples for rolling 

average. 

SET 4

View or change flow 

rate corresponding to 

4mA. 

SET 20

View or change flow 

rate corresponding to 

20mA. 

EXIT

Return to HOME 

SCREEN or enter 

SUBMENU

T UNIT

R UNIT SET P DAMP

SET 4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +  

 TO SET TOTAL

UNITS FOR DISPLAY

T UNIT

R UNIT

SET P DAMP

SET 4 SET 20 SET F

EXIT

FLOW RATE = GALLONS/MIN

PRESS       +       TO SET RATE

UNITS FOR DISPLAY

T UNIT R UNIT

SET P

DAMP

SET 4 SET 20 SET F

EXIT

00001.0

 GALLONS

PRESS       +       TO SET 

GALLONS TOTALIZED PER 

PULSE SENT OUT PULSE1

T UNIT R UNIT SET P

DAMP

SET 4 SET 20 SET F

EXIT

DAMPING = 1

PRESS       +       TO SET 

DAMPING VALUE

T UNIT R UNIT SET P DAMP

SET 4

SET 20 SET F

EXIT

00040.0

 GALLONS/MIN

PRESS       +  

 TO SET FLOW 

RATE AT WHICH 4mA

(MIN) OUTPUT IS DESIRED

T UNIT R UNIT SET P DAMP

SET 4

SET 20

SET F

EXIT

00200.0

 GALLONS/MIN

PRESS       +  

 TO SET FLOW 

RATE AT WHICH 20mA

(MAX) OUTPUT IS DESIRED

T UNIT R UNIT SET P DAMP

SET 4 SET 20 SET F

EXIT

PRESS       +  

 EXIT MENU 

AND RETURN TO FLOW

DISPLAY

Note: Available options will depend on specific meter configuration. Not all options are available on all meters.

 

Options not ordered with your meter will not appear on the meter menu.

Standard Menu Options

Special SUBMENU for Further Options

Summary of Contents for FMG480 Series

Page 1: ...e mail info omega com For latest product manuals omega com en us pdf manuals XXXXXX Xxxxx Xxxxxxxx Shop online at omega com User sGuide TM FMG490 SERIES Municipal Industrial Magmeter...

Page 2: ...ns without notice omega com info omega com Servicing North America U S A Omega Engineering Inc 800 Connecticut Ave Suite 5N01 Norwalk CT 06854 Headquarters Toll Free 1 800 826 6342 USA Canada only Cus...

Page 3: ...onfiguration Sourcing Mode Output Application Page 16 Sinking Mode Output Application Page 16 Analog 4 20mA Current Loop Output Application Page 16 Cable Shield Page 17 Pulse Output Page 17 Analog 4 2...

Page 4: ...t flow batch forward flow and batch reverse flow Batch totals can be reset Built in data logging is available as an option for secure flow logging Scaled pulse output is standard and one additional ou...

Page 5: ...gal Cubic Meters Cubic Meters x 1000 Cubic Feet Cubic Feet x 1000 Second Foot Day Million Cubic Feet Acre Feet Acre Inches Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons Fluid Ounce...

Page 6: ...ter Size L H T ID Shipping Weight inch mm inch mm inch mm inch mm lbs Kg 3 12 25 311 7 08 179 8 68 17 25 2 6 66 04 40 18 4 10 12 257 8 3 211 62 15 7 3 12 79 43 19 5 6 12 09 307 9 1 231 69 17 5 5 05 12...

Page 7: ...0 6 8 10 FMG490 Accuracy Pipe Size Inches in diameter 3 4 6 8 10 12 Max Flow Rate Gallons Minute 723 1285 2891 5140 8031 11565 Cut off min Flow Rate Gallons Minute 3 62 6 43 14 46 25 70 40 15 57 82 M...

Page 8: ...ing Flow Propeller Meter Partially Open Butterfly Valve 1X 1X 1X 1X Swirling Flow NOTE These configurations are to be used as general guidelines and do not cover every possible installation A combinat...

Page 9: ...ent on the electrodes can affect accuracy Recommended Improved accuracy results from unimpeded electrodes Electrode moved from top by rotating meter Intermittent air bubbles miss electrode Electrodes...

Page 10: ...er ANSI 150 lb flanges See table on page 11 for flange bolt tightening torque specifications Calibration The FMG490 meters are factory calibrated and will not require any form of field calibration Che...

Page 11: ...tem must be grounded to meet national and local electrical safety codes Failure to do so can result in electrocution Equalization Lug Meter Flange Pipe Flange Gasket Pipe Flange Flange Plate Lockwashe...

Page 12: ...e 1 Cable Gland Opening and Sealing The display is available in either DC or AC versions DC version AC Version If the meter is configured with AC power one of the additional Power Output cable ports m...

Page 13: ...latory agency approval If installed outdoors or less than 33ft 10m from a utility power service entrance AC power should be supplied via a properly grounded surge suppression device 10 Remove the plug...

Page 14: ...sensor cable inside the internal strain relief clip and tighten the cable gland sealing nut securely torque strain relief sealing gland dome nut to 22 in lbs A lose nut could cause moisture ingress an...

Page 15: ...ange R Remote B pn11 Blue R Remote A pn12 Black C1 DC pn14 Red C1 DC pn15 WARNING BACKUP BATTERIES ARE NOT INTENDED AS A PRIMARY POWER SOURCE OF A MAINS DC or AC CONFIGURED METER Remove the 3 screws h...

Page 16: ...D5L D6L RED C1 BLACK C1 BLUE R ORNG R BLACK R RED R BLUE C1 ORNG C1 GREEN C1 WHITE C1 A5N A6N RED INT BLACK INT BLUE R ORNG R BLACK R RED R GREEN C1 WHITE C1 A5L A6L RED INT BLACK INT BLUE R ORNG R BL...

Page 17: ...pplication Sinking Mode Recommended for Rin 30k Analog 4 20mA Current Loop Output Application Minimum resistor value is 100 x Vs ohms Higher resistances maybe used depending on frequency and cable len...

Page 18: ...units totaled per pulse all sizes of meters can be configured with the same SETP values For example if your rate is chosen as gallons per minute GPM the table below applies If your rate is different...

Page 19: ...perform the hold and tap sequence When finished making changes When you are finished making changes move to the EXIT tab using the right button To return to the HOME screen perform the hold and tap s...

Page 20: ...g average SET 4 View or change flow rate corresponding to 4mA SET 20 View or change flow rate corresponding to 20mA EXIT Return to HOME SCREEN or enter SUBMENU T UNIT R UNIT SET P DAMP SET 4 SET 20 SE...

Page 21: ...the number of samples for rolling average of pulse output TEST TEST allows the user to initiate a fully functional artificial flow rate for the purpose of testing other connected equipment When TEST i...

Page 22: ...correct but pulse frequency output is low erratic or absent Wiring incorrect Compare wiring with appropriate wiring recommendations External device input impedance too low Use sourcing rather than sin...

Page 23: ...nation by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but no...

Page 24: ...as Mass Flowmeters Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controll...

Reviews: