4. Selecting 

Location

• 

The FMG-3000 requires a full pipe and a fully developed turbulent fl ow profi le for accurate measurement.

• 

If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the 
electrodes.

• 

In vertical installations, assemble the unit so the conduit ports are facing downward.  This prevents condensation inside the conduit 
from being directed into the electronics housing.

15 x I.D.

5 x I.D.

Reducer

+GF+

10 x I.D.

5 x I.D.

Inlet

Outlet

Flange

+GF+

50 x I.D.

5 x I.D.

Valve/Pump

+GF+

40 x I.D.

5 x I.D.

2 x 90° Elbow
3 dimensions

+GF+

25 x I.D.

5 x I.D.

2 x 90° Elbow

+GF+

20 x I.D.

5 x I.D.

90° Elbow

+GF+

+G

F+

+

GF

+

+GF+

+

GF

+

+G

F+

+GF+

O.K.

O.K.

O.K.

Vertical flow is OK IF the pipe remains full at all times.

3. Installation: 

 

Pipe 

fi ttings

Omega offers a wide selection of installation fi ttings that control the position of the Magmeter electrodes in relation to the dimensions of 
the pipe.  You will fi nd a complete list of order numbers for installation fi ttings in the Calibration tables on pages 9-13.

Select a location with suffi cient 
distance of straight pipe immediately 
upstream of the sensor.

Locating the sensor in a trap or where the 
fl ow is upward helps to protect the sensor 
from exposure to air bubbles when the 
system is in operation.
NOTE: The system must be designed to 
keep the sensor wet at all times.  

These confi gurations are not 
recommended because it is diffi cult to 
keep the pipe full.

Type

Description

2 to 4 inch, cut 1-7/16 inch hole in pipe
Over 4 inch, cut 2-1/8 inch hole in pipe

0.5 to 4 inch versions 
PVC or CPVC

2 to 4 inch, cut 1-7/16 inch hole in pipe
6 to 8 inch, cut 2-1/8 inch hole in pipe

Iron, Carbon Steel, 
316 SS Threaded 
tees

Carbon steel & 
stainless steel 
Weld-on
Weldolets

2 to 4 inch, cut 1-7/16 inch hole in pipe
Over 4 inch, cut 2-1/8 inch hole in pipe

For pipes DN 65 to 200 mm
PP or PVDF

For pipes from DN 15 to 50 mm
PP or PVDF

Type

Description

Plastic tees

Metric 
Wafer Fitting

Metric 
Union 
Fitting

PVC
Saddles

Iron
Strap-on
saddles

1.5 in. to 8 in. PVDF insert      
> 8 in. PVC insert

Fiberglass
tees &
saddles:

FPT

FPS

0.5 to 2 in. versions
Mounts on threaded pipe ends

In a gravity-fl ow system, the tank must be designed 
so the level does not drop below the outlet.

This causes the pipe to draw air in from the tank.
If air bubbles pass across the Magmeter electrodes, 
the output will become erratic.  

+GF+

Summary of Contents for FMG3000 SERIES

Page 1: ...eter User sGuide omega com omega comTM www omega com e mail http omegamanual info For latest information and product manual visit www omegamanual info ISO9001 CERTIFIED CORPORATE QUALITY STAMFORD CT I...

Page 2: ...2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA Mexico En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info o...

Page 3: ...e Magmeter into the pipe Use Omega installation ttings ONLY The installation tting is critical to Magmeter performance Sec 3 4 Pg 3 3 Connect POWER and OUTPUT wiring FMG 3001 and FMG 3101 Frequency ou...

Page 4: ...Current output 4 to 20 mA Programmable and reversible Loop Accuracy 32 A max error 25 C 24 VDC Temp drift 1 A per C max Power supply rejection 1 A per V Isolation Low voltage 48 VAC DC from electrode...

Page 5: ...straight pipe immediately upstream of the sensor Locating the sensor in a trap or where the ow is upward helps to protect the sensor from exposure to air bubbles when the system is in operation NOTE T...

Page 6: ...to the smaller terminal block These connections should always remain connected to prevent inadvertent damage or miswiring The terminals on the FMG 3000 Magmeter are designed for conductors from 16 AWG...

Page 7: ...3000 Use anged grounding rings or metal electrodes on plastic pipes or metal clamps on metal pipes Fluid grounds must be in direct contact with the uid and as near to the Magmeter as possible The shie...

Page 8: ...TTING K Factor K Factor 20 mA 20 mA IN TYPE Gallons Liters in GPM in LPM SCH 80 IRON SADDLE ON SCH 80 PIPE 2 FP 5320GI 194 85 51 48 153 96 582 75 2 FP 5325GI 142 28 37 59 210 86 798 10 3 FP 5330GI 87...

Page 9: ...5307C 1381 48 364 99 21 72 82 19 1 FP 5310C 857 98 226 68 34 97 132 34 1 FP 5312C 445 17 117 61 67 39 255 07 1 FP 5315C 325 56 86 01 92 15 348 78 SCH 80 PVC SADDLES FOR SCH 80 PVC PIPE 2 FP 5320S 193...

Page 10: ...08 412 86 2 FP 5120PO 156 87 41 45 191 24 723 83 PVDF FITTINGS DIN ISO BS ANSI FP 5105 1946 49 514 26 15 41 58 34 FP 5107 1158 05 305 96 25 91 98 05 1 FP 5110 749 09 197 91 40 05 151 58 1 FP 5112 439...

Page 11: ...0 36 84 9 73 814 34 3082 28 4 FMG 5350 29 28 7 73 1024 70 3878 50 4 FMG 5360 20 29 5 36 1478 26 5595 21 8 FMG 5380 11 73 3 10 2557 72 9680 96 10 FMG 5381 7 45 1 97 4028 83 15249 1 12 FMG 5382 5 24 1 3...

Page 12: ...PPER TEES FITTING ON COPPER PIPE SCH L FP 5305CU 2406 30 635 75 12 47 47 19 FP 5307CU 1174 77 310 37 25 54 96 66 1 FP 5310CU 672 28 177 62 44 62 168 90 1 FP 5312CU 402 84 106 43 74 47 281 87 1 FP 5315...

Page 13: ...3000 is wrong model Blue jumper not in correct position Wiring is not correct Frequency input to other manufacturer s ow instrument does not have pull up resistor Frequency model is FMG 3001 and FMG...

Page 14: ...PVDF TI OMEGAMAG Blind Freq PVDF Ti 5 8 OMEGAMAG with 4 20 mA Loop Output FMG3002 PP OMEGAMAG Blind Loop PP 316SS 4 FMG3102 PP OMEGAMAG Blind Loop PP 316SS 5 8 FMG3202 PP OMEGAMAG Blind Loop PP 316SS...

Page 15: ...t exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not i...

Page 16: ...rs Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pump...

Reviews: