8
FHG 100
Interpolation
factor (IPF)
Switch
position
S3
Measurement
volume V
m
[cm
3
/Imp]
K-Factor
[Imp/l]
K-Factor
[Imp/
gal.]
1
0
0,5815
1720
6510
2
1
0,29075
3439
13020
5
2
0,11630
8598
32549
10
3
0,05815
17197
65098
25
4
0,02326
42992
162745
32
5
0,01817
55036
208335
50
6
0,01163
85985
325489
64
7
0,00909
110011
416440
100
8
0,00582
171821
650419
128
9
0,00454
220264
833797
FHG 400
Interpolation
factor (IPF)
Switch
position
S3
Measurement
volume V
m
[cm
3
/Imp]
K-Factor
[Imp/l]
K-Factor
[Imp/
gal.]
1
0
3,138
319
1206
2
1
1,569
637
2413
5
2
0,6276
1593
6032
10
3
0,3138
3187
12063
25
4
0,12552
7967
30158
32
5
0,09806
10198
38603
50
6
0,06276
15934
60316
64
7
0,04903
20396
77207
100
8
0,03138
31867
120632
128
9
0,02452
40783
154382
FHG 800
Interpolation
factor (IPF)
Switch
position
S3
Measurement
volume V
m
[cm
3
/Imp]
K-Factor
[Imp/l]
K-Factor
[Imp/
gal.]
1
0
10,00000
100
379
2
1
5,00000
200
757
5
2
2,00000
500
1893
10
3
1,00000
1000
3785
25
4
0,40000
2500
9464
32
5
0,31200
3200
12113
50
6
0,20000
5000
18927
64
7
0,15625
6400
24227
100
8
0,10000
10000
37854
128
9
0,07813
12799
48451
FHG 2500
Interpolation
factor (IPF)
Switch
position
S3
Measurement
volume V
m
[cm
3
/Imp]
K-Factor
[Imp/l]
K-Factor
[Imp/
gal.]
1
0
37,00000
27
102
2
1
18,50000
54
204
5
2
7,40000
135
511
10
3
3,70000
270
1022
25
4
1,48000
675
2555
32
5
1,15625
864
3270
50
6
0,74000
1350
5110
64
7
0,57813
1728
6540
100
8
0,37000
2700
10220
128
9
0,28906
3456
13081
Table 3: Measurement volumes and K-factors
Formula 2: Calculating the max. IPF
The set IPF may not be larger than the calculated IPF!
IPF
Interpolation factor
f
max
Max. processable input frequency
V
mIPF1
Measurement volume with IPF = 1 (volume of a gear structure of the sensing wheel)
Q
max
Max. operating flow in l/min
IPF ≈ f
max
x Vm
IPF1
x 60
Q
max
x 1000