background image

“SecureCode” allows the user to customize the number of Valet Switch
presses which are required to successfully perform an Emergency Override.
The basic Emergency Override procedure is described on pages 12-
13
.  Instead of a single “1 press” of the Valet Switch which would be required
in order to perform an Emergency Override, two stages of Valet Switch
presses must be made.  In each of the two stages, the Valet Switch will need
to be pressed 1 through 9 times, as programmed by the user.  This is the
Emergency Override procedure if the system has programmed with a
customized SecureCode:

Step 1 With the system in the armed condition, enter the vehicle via the

driver's door (be aware that the system will activate to an alarm
condition when the door is opened).

SecureCode

Page - 21

Once the system is disarmed, if Alarm Valet Mode is desired, just press

and hold the Valet Switch for 2 seconds to place the system into Valet Mode.
Should a mistake be made entering the SecureCode, after a failed attempt
to achieve SecureCode, the ignition switch must be turned off, then on again
before another attempt is made.

Step 4 After a few seconds, the siren will stop sounding, chirp once, and

then resume sounding.

Step 2 Using the ignition key, turn the vehicle’s ignition switch on.

Step 3 Within 5 seconds press and release the Valet Switch the same

number of times that have been programmed for stage #1.

Step 5 Now, within 5 seconds press and release the Valet Switch the same

number of times that have been programmed for stage #2.  Within
a few seconds the siren will stop sounding, and the unit will disarm.

In addition to Emergency Override, if any of the three anti-carjacking

features are utilized, a correct customized SecureCode would also be
required to turn off anti-carjacking once it has become fully activated.  How
to program your own customized SecureCode is explained on page 30.

Should two failed SecureCode attempts be made, the system will ignore
any further presses of the Valet Switch for two minutes.

Step 2

Turning the ignition back on.

Page - 24

Anti-Carjacking Protection

The Omega AL-1610-EDP features three separate Anti-Carjacking

protection features, whose operation may be selectively activated by the
ignition, by an open door, or by the transmitter.  All three are programmable,
and must be turned on to operate.  Once activated, the user has 53 seconds
to cancel the Anti-Carjacking protection process by pressing the Valet
Switch once.  If Anti-Carjacking is not cancelled, 53 seconds after being
activated the siren will begin to chirp for 7 seconds to alert the user that the
system is about to enter into an alarm condition.  The Valet Switch may still
be pressed once during this period to cancel the Anti-Carjacking process.

If the Anti-Carjacking process is not cancelled before the 60 second

countdown expires, the system will enter an alarm condition, sounding the
siren and flashing the parking lights.   30 seconds after this occurs, or
should the ignition be turned off in the meantime, the stater interrupt will
engage.    Once the system enters the alarm condition, it will not respond
to the transmitter, nor will the system reset automatically after 60 seconds,
and it can only be disengaged by:

Step 1

Turning the vehicle’s ignition off.

The three types of Anti-Carjacking protection features are:

Anti-Carjacking protection activated using a transmitter has the process
start by pressing and holding the 

OPTION

 and red “|||” buttons together

for 3 seconds, but only if the vehicle’s ignition is on.  The Valet Switch must
be pressed within 60 seconds after this is done to cancel Anti-Carjacking.
This is User Programmable Feature #19 (pages 27,28, and 36).

Anti-Carjacking protection activated an open door has the process start
should a door be opened after the vehicle is started and the engine is
running.  The Valet Switch must be pressed within 60 seconds after the door
is opened to cancel Anti-Carjacking.  This is User Programmable Feature
#18 (see pages 27,28, and 36).

Anti-Carjacking protection activated by the vehicle’s ignition has the
process start every time the vehicle’s ignition is turned on.  The Valet Switch
must be pressed within 60 seconds every time the vehicle is started to
cancel Anti-Carjacking.  This is User Programmable Feature #17 (see
pages 27,28, and 35).

Step 3

Within 5 seconds, perform an Emergency Override using the Valet

Switch.  If the SecureCode has been customized, the correct
number of Valet Switch presses must be made.

Summary of Contents for Excalibur AL-1610-EDP

Page 1: ...s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or its contents or any incidental or cons...

Page 2: ...doorlock U ON w doorlock 4 Starter Interrupt Functions Alarm only L Off U Automatic Alarm AntiGrind 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock Wi...

Page 3: ...ect the engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This featu...

Page 4: ...which keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will t...

Page 5: ...rn Output press arm lock button to program Options Door Unlock press disarm unlock button to program Ignition Output press button to program Accessory Output press red button to program This is the se...

Page 6: ...some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double Pulse Unlock setting pr...

Page 7: ...mable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution These features hav...

Page 8: ...tus Light flashes in the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the syst...

Page 9: ...t 30 seconds the Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To t...

Page 10: ...not recommended Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insur...

Page 11: ...isual disarming indications and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button...

Page 12: ...Step 3 Within 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which...

Page 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning the...

Page 14: ...tely stop it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This fea...

Page 15: ...Omega AL 1610 EDP is installed into a manual transmission vehicle Installer Pro grammable Feature 5 must be turned on Then whenever remote start ing will be desired at a later time the following proce...

Page 16: ...the engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren...

Page 17: ...tep 4 Within 10 seconds Press Release the Valet Switch the same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Vale...

Page 18: ...m unlock and red buttons will activate the 5th channel Or if desired the transmitter button can be programmed by User Programming Feature 21 page 36 to operate any of these channels Page 18 To a large...

Page 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Page 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Page 21: ...Carjacking protection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once acti...

Page 22: ...smitters are programmed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door...

Reviews: