background image

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 

13 months

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month

grace period to the normal 

one (1) year product warranty

to cover handling and shipping time. This

ensures that OMEGA’s customers receive maximum coverage on each product. 

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits, 
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of 
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not 
limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, 
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR 
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF 
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of 
OMEGA with respect to this order, whether based on contract, warranty, negligence, 
indemnification, strict liability or otherwise, shall not exceed the purchase price of the 
component upon which liability is based. In no event shall OMEGA be liable for 
consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit. 

FOR 

WARRANTY

RETURNS, please have the 

following information available BEFORE 
contacting OMEGA:
1. Purchase Order number under which the product

was PURCHASED,

2. Model and serial number of the product under

warranty, and

3. Repair instructions and/or specific problems 

relative to the product.

FOR 

NON-WARRANTY

REPAIRS, consult OMEGA

for current repair charges. Have the following
information available BEFORE contacting OMEGA:
1.  Purchase Order number to cover the COST 

of the repair,

2. Model and serial number of the product, and
3. Repair instructions and/or specific problems 

relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2009 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.

Summary of Contents for EP510 Series

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info EP510 IP510 EP511 IP511 SERIES Electroneumatic Converters Shop online at User sGuide MADE IN ...

Page 2: ...ce Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0800 6397678 TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 e mail info omega de United Kingdom OMEGA Engineering Ltd ISO 9001 Certified One Omega Drive River Bend Technology Centre Northbank Irlam Manc...

Page 3: ...G In order to get optimal service from this transducer and ensure warranty coverage the following MUST be followed The supply air quality to this instrument must be instrument quality air as defined by ISA Standard 57 0 01 1996 1 Dew point not higher than 35 F 2 No particulates larger than 3 microns in size 3 Maximum oil content of 1 ppm No mechanical adjustments or calibrations are necessary or a...

Page 4: ... 32 screws using threaded holes in the bottom of a transducer NEMA 4X transducers may be mounted to a panel with three No 10 32 screws using threaded holes in the back of a transducer or with four No 8 32 screws using threaded holes in the bottom of a transducer In the case of back mount ing if the panel extends towards the screw on cover a 3 16 inch thick spacer MUST be used between the back of t...

Page 5: ...ould installation next to high electromagnetic interference be necessary WARNING In explosive atmospheres electrical power must be removed from the transducer before attempting to remove the cover and until the cover is fully reinstalled Failure to do so may result in electrical spark or explosion CAUTION Care must be used when inserting wires into the NPT port Wires must not enter below the circu...

Page 6: ...nsducers should provide more than one million cycles without failure If a situation should occur in which the transducer s behavior is abnormal the cause is usually related to a pneumatic problem ELECTRICAL MAINTENANCE An electrical problem must be isolated by a skilled technician The power source and all wiring should be checked first Circuit board failures are very rare and can be confirmed by t...

Page 7: ...ries transducers are rated intrinsically safe by both FM and CSA for CLASS I DIVISION 1 GROUPS A B C D HAZARDOUS LOCATIONS Proper FM approved intrinsically safe wiring requires external FACTORY MUTUAL RESEARCH CORPORATION ENTITY APPROVED SINGLE CHANNEL barriers to be selected based upon MAXIMUM ENTITY PARAMETERS of 510 and 511 Series transducers ENTITY PARAMETERS Vmax 28 V Imax 150 mA Ci 0 22uF Li...

Page 8: ...plied In case of a need for replacement parts follow TABLE 4 EXPLOSION PROOF FOR CLASS I DIV 1 GROUP B C D DUST IGNITION PROOF FOR CLASS II DIV 1 GROUP E F G SUITABLE FOR CLASS III LOCATIONS M 4109 1104 IP510 EP510 IP511 EP511 SERIES A 8 TABLE 3 NEMA 4X REPLACEMENT COVER O RINGS PART NAME PART NUMBER O RING SEAL VITON 214 649 000 242 O RING SEAL BUNA N 214 649 000 240 TABLE 4 NEMA 4X REPLACEMENT P...

Page 9: ...ngs 010137 002 8 Standard outlet range orifice with Buna N O rings 010137 001 9 Standard outlet range orifice with Viton O rings 010137 003 10 Hirschmann Connector Kit 3 prong plug O ring sealed 010142 000 11 Pressure Gauge Kit 15 PSI 010138 000 12 Pressure Gauge Kit 30 PSI 010138 001 13 Pressure Gauge Kit 60 PSI 010138 002 14 Pressure Gauge Kit 160 PSI 010138 003 EP511 AND IP511 SIDE VIEW SIDE VI...

Page 10: ... F to 160 F Storage Temperature Range Buna N elastomers Viton elastomers 40 F to 200 F 15 F to 200 F Vibration Effect Less than 0 5 of SPAN per 1G 5 2000 Hz 3G maximum 3 axes Mounting Position Effect Not measurable Loop Load I P transducer Less than 10 VDC drop at 20 mA Less than 12 VDC drop at 50 mA Supply Voltage E P Transducer Intrinsically Safe Nonincendive General Purpose 9 VDC to 28 VDC less...

Page 11: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Page 12: ...tors 䡺 Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Data Logging Systems 䡺 Reco...

Reviews: