DMD4059 

DMD4059-DC 

Strain Gauge to DC Isolated Transmitter

M-5000/0818

Model

Power

DMD4059

85-265 VAC, 50/60 Hz or 60-300 VDC

DMD4059-DC

9-30 VDC or 10-32 VAC

Description

The DMD4059 accepts an input from one to four strain gauges, 
bridge sensors, load cells, or pressure transducers. It filters, 
amplifies, and converts the resulting millivolt signal into the 
selected DC voltage or current output that is linearly related to 
the input.
The full 3-way (input, output, power) isolation makes this module 
useful for ground loop elimination and signal isolation.
The adjustable excitation power supply generates a stable 
source of voltage to drive from one to four 350 

 (or greater) 

devices. Sense lead circuitry is included to cancel the effects of 
leadwire resistance.
Input, output, excitation and zero offset (up to ±100% of span) 
are field configurable. Non-interactive zero and span simplifies 
calibration. 
A 20 VDC loop excitation supply for the output can be selectively 
wired to power passive mA devices. 
A green input LED and a red output LED vary in intensity with 
changes in the process input and output signals. 
An output test button provides a fixed output (independent of the 
input) when held depressed. The test output level is potentiom-
eter adjustable from 0 to 100% of output span. 

Strain Gauge Input Ranges

100 

Ω 

to 10,000 

Ω 

bridges at 10 VDC 

Up to four 350 

 bridges at 10 VDC

Minimum: 

0 to 5 mV range 

0.5 mV/V sensitivity 

Maximum: 

0 to 400 mV range  40 mV/V sensitivity

Millivolt output range is determined by the sensor sensitivity 
(mV/V) and the excitation voltage:  
mV/V sensitivity  X  excitation voltage  =  total mV range

Input Impedance

200 k

 typical

Common Mode Rejection

100 dB minimum

Calibration Resistor Options

M01 option:  Switch with calibration resistor inside module.  
 

Specify resistor value. 

M02 option:  Switch for external (load cell) calibration resistor.

Excitation Voltage

Switch Selectable:  0-10 VDC in 1 V increments 
Maximum Output:  10 VDC maximum at 120 mA 
Drive Capability: 

Up to four 350 

 bridges at 10 VDC 

Fine Adjustment: 

±5% via multi-turn potentiometer 

Stability: 

±0.01% per °C

Sense Lead Compensation

Better than ±0.01% per 1 

 change in leadwire resistance 

Maximum leadwire resistance: 10 

 with 350 

 at 10 VDC

LoopTracker

Variable brightness LEDs for input/output loop level and status

DC Output Ranges

Voltage (10 mA max.): 

0-1 VDC 

to  0-10 VDC 

Bipolar Voltage (±10 mA max.):  ±5 VDC 

or  ±10 VDC 

Current: 

0-2 mADC  to  0-20 mADC 

Compliance, drive at 20 mA: 

20 V, 1000 

 drive 

Current output can be selectively wired for sink or source

Output Calibration

Multi-turn zero and span potentiometers 
±15% of span adjustment range typical
Zero offset switch:  ±100% of span in 15% increments

e-mail: [email protected] 

For latest product manuals: 

www.omegamanual.info

Shop online at 

omega.com

User’s Guide

Lifetime

TM

MADE IN

WARNING:

 This product can expose you to chemicals includ-

ing nickel, which are known to the State of California to cause 

cancer or birth defects or other reproductive harm. For more 

information go to www.P65Warnings.ca.gov

Output Test

Sets output to test level when pressed 
Adjustable 0-100% of span 
Not available with M01 or M02 options

Output Ripple and Noise

Less than 10 mV

RMS

 ripple and noise

Linearity

Better than ±0.1% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

70 milliseconds typical (14.2 Hz) 
DF option: 10 millisecond response time typical (100 Hz) 
Contact factory for custom response times

Isolation

1200 V

RMS

 min. 

Full isolation: power to input, power to output, input to output

Housing and Connectors

IP 40, requires installation in panel or enclosure 
For use in Pollution Degree 2 Environment 
Mount vertically to a 35 mm DIN rail
Four 4-terminal removable connectors 
14 AWG max wire size 

Dimensions

0.89" W x 4.62" H x 4.81" D   
22.5 mm W x 117 mm H x 122 mm D  
Height includes connectors

Power

Standard:  85-265 VAC, 50/60 Hz or 60-300 VDC 

D

 option: 

9-30 VDC (either polarity) or 10-32 VAC

Power:  

2 to 5 Watts depending on number of load cells

Summary of Contents for DMD4059

Page 1: ...ncrements Maximum Output 10 VDC maximum at 120 mA Drive Capability Up to four 350 Ω bridges at 10 VDC Fine Adjustment 5 via multi turn potentiometer Stability 0 01 per C Sense Lead Compensation Better than 0 01 per 1 Ω change in leadwire resistance Maximum leadwire resistance 10 Ω with 350 Ω at 10 VDC LoopTracker Variable brightness LEDs for input output loop level and status DC Output Ranges Volt...

Page 2: ...000V 008V 001V 006V 009V 002V 007V 003V 004V 005V 000I 008I 001I 006I 009I 002I 007I 003I 0 100 mV 800V 808V 801V 806V 809V 802V 807V 803V 804V 805V 800I 808I 801I 806I 809I 802I 807I 803I 0 120 mV F00V F08V F01V F06V F09V F02V F07V F03V F04V F05V F00I F08I F01I F06I F09I F02I F07I F03I 0 200 mV 100V 108V 101V 106V 109V 102V 107V 103V 104V 105V 100I 108I 101I 106I 109I 102I 107I 103I 0 250 mV 400V...

Page 3: ...tputs failure to illuminate or a failure to change in intensity as the process changes may indicate a problem with the module power or signal output wiring Diagnostic Voltage Measurements Using a meter with at least 10 megaohm input impedance measure the voltage coming from the strain gauge at the locations shown Sensitivity is measured in mV V Positive Meter Lead Negative Meter Lead Meter Reading...

Page 4: ...by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or ...

Reviews: